| Plan Review Stops For Permit 00091295 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-12 |
Time |
11:44 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-12 00:00:00 | PROVISO: PAY COUNTY IMPACT FEES, | | | RADON FEES. JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-02-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-26 |
Time |
09:38 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-26 00:00:00 | PERMIT # 00091295 | | | 4700 GEORGIA AV. | | | OVERLAND CONSTRUCTION | | | PHONE 683-3210 | | | | | | 1)- NOTICE OF COMMENCEMENT: OWNER NAME | | | ON PROPERTY APPRAISER IS DANIEL M FOWLER | | | ON THE PERMIT APPLICATION LISTED AS | | | FOWLER SHEET METAL, INC. THE BUILDING | | | DEPARTMENT WILL NEED TO SEE PROOF OF | | | CHANGE OF OWNERSHIP OR THE PERMIT APPLI- | | | CATION WILL NEED TO BE CHANGED, BOTH THE | | | NOTICE OF COMMENCEMENT & THE PROPERTY | | | APPRAISERS SCREEN MUST AGREE. | | | | | | 2)- SHEET A-5 DETAIL 4/A-5 EXISTING | | | BUILDING (LOT 61-64) SOUTH WALL OF NEW | | | BUILDING IS A PROPERTYLINE WALL. THE | | | OVERHANG AND GUTTER CANNOT OVERHANG THE | | | PROPERTYLINE WALL, NOR CAN THE EXISTING | | | BUILDING BE JOINED, UNDER DIFFERENT | | | QWNERSHIP & PROPERTY CONTROL NUMBER. | | | THE SOUTH WALL WILL REQUIRE A MINIMUM OF | | | A 3HR. WALL. TABLE 709.3.1 THE MINIMUM | | | EQUIVALENT THICKNESS FOR LIMESTONE | | | MASONARY WALLS IS A 5.0. SHOW COMPLIANCE | | | FIRE RATINGS MUST BE TAKEN FROM BOTH | | | SIDES OF THE WALL WHEN THE EXTERIOR | | | BUILDING WALL IS 5'-0" OR LESS IN HORI- | | | ZONTAL SEPERATION.NO OPENINGS. | | | | | | 3)- SHEET A-5 SECTION 3: (EAST WALL) | | | THIS WALL WILL ALSO REQUIRE A 3 HR. WALL | | | SHOW COMPLIANCE THE EQUIVALENT THICKNESS | | | FOR LIMESTONE MASONARY WALL (MINIMUM) IS | | | 5.0 TABLE 709.3.1. | | | | | | JIM WITMER | | | BUILDING PLAN REVIEW | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-01-22 |
Time |
07:38 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-22 00:00:00 | BUILDING PLAN REVIEW | | | 1)- DISCREPANCY, SHEET A-1 VS A-3 SITE | | | PLAN SHOWS GABLES AT THE NORTH/SOUTH | | | ELEVATION WHILE A-3 IN DICATES GABLES AT | | | EAST WEST ELEVATIONS? | | | 2)- ADDITIONAL INFORMATION SBC 104.2.2- | | | SHEET A-2 SHOWS A ROOM SIZE OF 16'-0"X | | | 36'-2" AND NO USEAGE LISTED? | | | 3)- ENERGY CALCS? | | | 4)- SBC 1606.2.6.2- COMPONENTS AND CLAD- | | | DING, ALL DOORS REQUIRE PRODUCT APPROVAL | | | REPORTS EITHER DADE COUNTY OR SBCCI | | | REPORT ARE ACCEPTED. | | | 5)- THIS BUILDING FALLS UNDER ONE OF TWO | | | CATEGORIES, MANUFACTURED BUILDINGS THAT | | | REQUIRE PLANS APPROVED BY DCA DEPARTMENT | | | OF COMMUNITY AFFAIRS OR IT IS A STEEL | | | ENGINEERED BUILDING (SBC 2201) THAT | | | REQUIRES ENGINEERED DRAWINGS, SIGNED, | | | SEALED AND DATED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2001-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-10 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-10 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2001-09-10 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE PLANS NEED TO SHOW | | | ALL BRANCH CIRCUIT #`S AND CORRELATE | | | WITH SUBMITTED PANEL SCHEDULES. | | | | | | 2)NOTE: PLEASE NOTE PLANS MISSING BLDG. | | | STEEL PER 250-50. | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 4)NOTE: PLEASE NOTE THAT BOTH PANELS ARE | | | SHOWN AS PANELS "LP"??? PLEASE CLARIFY. | | | | | | 5)NOTE: PLEASE NOTE THAT PLANS ONLY SHOW | | | LOCATION OF ONE PANEL?? PLEASE SHOW BOTH | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-06 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-06 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-01 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-01 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-27 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-27 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE NOTE THAT NO CHANGES | | | WERE MADE TO THE PLANS FROM FISRT SET | | | OF REVIEW NOTES. PLEASE ADDRESS ORIG | | | NOTES AND SUBMIT FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-22 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-22 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2001-01-22 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT | | | #`S ON PLANSAND CORRELATE WITH PANEL | | | SCHEDULES.215-5 | | | | | | 2)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | | CONDUCTOR GOING TO BLDG STEEL PER 250-50 | | | | | | | | | 3)NOTE"PLEASE LABEL PANEL LOCATIONS ON | | | PLANS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
N |
Date |
2001-01-29 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2001-01-29 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-30 00:00:00 | SEE SECOND REVIEW FOR COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-01-29 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2001-01-29 |
Time |
16:23 |
Rev Time |
0.50 |
| Received By |
dlauderm |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-29 00:00:00 | FAILED: | | | PLEASE REVISED DUMPSTER AREA AS PER OUR | | | STANDARD MINIMUM DETAIL DIMENSION. SEE | | | ATTACHED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-05 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-05 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-02-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-21 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-21 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2001-02-21 00:00:00 | 1) BUILDING ADDRESS REQUIRED PER CITY | | | CODE REQUIREMENTS. | | | 2) PROVIDE EMERGENCY LIGHTING IN ALL | | | MEANS OF EGRESS. | | | 3) INTERIOR FINISH INFORMATION NOT | | | PROVIDED. INTERIOR FINISH IN EXITS | | | SHALL BE CLASS A OR B. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-02-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-05 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-05 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2001-02-05 00:00:00 | 1) PLEASE INDICATE THE TYPE OF ACTIVTIY | | | THAT WILL OCCUR IN THE MANUFACTURING | | | AREA OF THE BUILDING. | | | 2) PLEASE PROVIDE AN OCCUPANT LOAD AND | | | A LIFE SAFETY PLAN FOR THE BUILDING. | | | 3) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR THE | | | WALLS AND CEILINGS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-02-27 |
Time |
16:34 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-02-27 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | *****************DENIED***************** | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW. | | | | | | PROVIDE EQUIPMENT INFORMATION, DUCT | | | LAYOUT, AIR BALANCE, FRESH AIR | | | CALCULATIONS AND EXHAUST FAN | | | SPECIFICATIONS. | | | | | | SUBMIT PLANS WITH MECHANICAL PERMIT | | | APPLICATION PRIOR TO START OF ANY | | | MECHANICAL WORK BEING DONE. | | | | | | NOTE:IF ABOVE CEILING IS RETURN PLENUM | | | THERE SHALL BE NO COMBUSTIBLES IN | | | THIS SPACE AS PER 97 SMC 609.1.1. | | | | | | REFERENCE DRAWING M-1, HVAC NOTES | | | #5 - EMERGENCY PAN MUST HAVE A | | | FLOAT SWITCH AS PER 97 SMC | | | 304.8.6.1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-02-02 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-02-02 |
Time |
09:08 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-02-02 |
Time |
9:28 |
Sent To |
|
|
| Notes |
| 2001-02-02 00:00:00 | INSUFFICIENT INFORMATION FOR | | | MECHANICAL REVIEW. | | | | | | PROVIDE EQUIPMENT SPECIFICATION, AIR | | | BALANCE SCHEDULES, EXHAUST FAN | | | SPECIFACTIONS WITH MECHANICAL PERMIT | | | APPLICATION. | | | | | | IF ABOVE CEILING IS RETURN PLENUM, | | | THERE SHALL BE NO COMBUSTIBLES IN THIS | | | SPACE AS PER 1997 SMC 609.1.1. | | | | | | REFERENCE DRAWING M-1, HVAC NOTES, #5 | | | 2" EMERGENCY PAN MUST HAVE A FLOAT | | | SWITCH AS PER 1997 SMC 304.8.6.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2001-03-28 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2001-03-28 |
Time |
10:21 |
Rev Time |
0.25 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-28 00:00:00 | OK PER JLEACH 3/27/2001 SEE APPDR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-03-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-16 |
Time |
07:49 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-03-16 |
Time |
07:49 |
Sent To |
|
|
| Notes |
| 2001-03-16 00:00:00 | DENIED; | | | | | | 1.MANUFACTORING AREA SHALL HAVE BATHROOM | | | FACILITYS. 94 SPC TABLE 407. | | | | | | 2.SINK IN BREAK ROOM SHALL COMPLY WITH | | | FACBC SEC. 4.24.1 THRU 4.24.7. SHOW | | | ARCHITECTAL DRAWING. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-03-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-16 |
Time |
07:16 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2001-03-16 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2001-03-16 00:00:00 | DENIED; | | | | | | 1.PAGE A-2 NOTE; AREA DATA, SHOWS OFFICE | | | 1168 SQ. FT. NEW LAYOUT SHOWS 576 SQ. | | | FT. (GARAGE), MANUFACTURING THAT | | | LEAVES 4774 SQ. FT. OF OFFICE SPACE. | | | 94 SPC TABLE 407. 48 PEOPLE EQUALS | | | 2 W/C AND 2 LAVS. FOR MALE& 2 AND 2 | | | FOR FEMALE. | | | | | | 2.SINK IN BREAK ROOM SHALL COMPLY WITH | | | FACBC SEC. 4.24.1 THRU 4.24.7. MAKE | | | NOTE OR SHOW ARCHITECTAL DRAWING. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-02-27 |
Time |
13:40 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-02-27 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | DENIED; | | | | | | 1.BATHROOM FACILITIES ARE REQUIRED IN | | | MANUFACTURING AREA. SUBMIT INFORMATION | | | SHOWING NUMBER OF EMPLOYEES PER SHIFT | | | AND INDICATE LIGHT OR HEAVY MANUFACT- | | | URING. | | | | | | 2.PAGE M-1 NOTE 8; | | | A. FLOOR DRAINS ARE NOT SHOWN ON | | | SANITARY RISER DIAGRAM. | | | B.SPECIFY TYPE OF AIR ARRESTERS TO | | | BE USED. AIR ARRESTERS MUST BE | | | ASSESIBLE 607.8.2 AND 607.8.3. | | | | | | 3.SINK IN BREAK ROOM; SHOW ARCHITECTAL | | | DRAWING MEETING ALL REQUIREMENTS OF | | | 97 FACBC SEC. 4.24.1 THRU 4.24.7. | | | | | | 4. PLUMBING RISER NOT CORRECT. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-01-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-18 |
Time |
08:59 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-01-18 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2001-01-18 00:00:00 | DENIED; | | | | | | 1.PAGE A-2 29" REQUIRED FROM FLOOR TO | | | BOTTOM OF HANDICAP LAV. | | | | | | 2.94 SPC TABLE 407 REQUIRES ONE DRINKING | | | FOUNTAIN IN OFFICE AREA. | | | | | | 3.ADDITIONAL INFORMATION REQUIRED TO | | | FINE THE NUMBER OF PLUMBING FIXTURES | | | REQUIRED IN MANUFACTURING AREA. | | | A.LIGHT OR HEAVY MANUFACTORING. | | | B.NUMBER OF EMPLOYEES PER SHIFT. | | | TABLE 407. | | | | | | 4.PAGE M-1 NOTE 8; | | | A.NO FLOOR DRAINS ARE SHOWN ON | | | SANITARY RISER. ARE FLOOR DRAINS | | | IN BATHROOMS? | | | B.AIR CHAMBERS MUST COMPLY TO 94 SPC | | | 607.8.2. | | | | | | 5.DRAWINGS SHOW SINK IN BREAK ROOM. THAT | | | SINK IS NOT SHOWN ON SANITARY RISER. | | | IF IS INSTALLED IT MUST COMPLY TO THE | | | 97 FACBC SEC. 4.24.1 THRU 4.24.7. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-03-12 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-10-05 |
Time |
09:44 |
Rev Time |
0.15 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS LEVEL 1 SITE PLAN REVIEW |
|
|