Plan Review Details - Permit 00091180
| Plan Review Stops For Permit 00091180 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-15 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-15 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-11-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-13 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-13 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE RISER, FEEDERS ARE | | | SHOWN AT 400 MCM 320A . NOT RATED FOR | | | 400A SERVICE. | | | | | | 2)NOTE: RISER AND PANEL SCHEDULE DO NOT | | | CORRELATE. ONE SHOWS MCB AND THE OTHER | | | MLO. PLEASE CLARIFY. | | | | | | 3)NOTE:PLEASE CLARIFY THE 220V OUTLET | | | IN GARAGE. PLEASE SHOW ON PANEL SCHEDULE | | | | | | 4)NOTE: PLEASE SHOWON PANEL THE REQ`D | | | BATH(S) CIRCUIT(S) PER 210-11-C-3 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-11 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-11 |
Time |
19:39 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | | | 1)NOTE: PLEASE SEE ELECTRICAL RISER | | | DIAGRAM,,, ONLY 1-SET OF 3/0 CONDUCTORS | | | SHOWN. PLEASE SEE AMPACITIES OF 310-15 | | | AND 310-16 75 DEGREE COLUMN. TOTAL LOAD | | | SHOWN AT 311AMPS?? PLEASE ADJUST | | | CONDUCTORS. | | | | | | 2)NOTE: ALSO, PLEASE SEE THE FOLLOWING | | | ARTS:373-7/373-8/380-3 FOR EQUIPMENT ETC | | | BEING USED AS RACEWAYS TO OTHER DISC`S | | | PANELS ETC. IF THE MAIN DISC IS BEING | | | USED AS RACEWAY? THEN IT MUST MEET ALL | | | CODES REFERENCED IN NEC. ALSO PLEASE | | | PLACE NOTE ON PLAN FOR THOSE REQ`MENTS | | | TO BE MET.IF NOT SHOW SECOND CONDUIT | | | FROM METERCAN TO 2ND MAIN DISC. | | | | | | 3)NOTE: PLEASE NOTE MISSING OUTLET PER | | | 210-52 AND PLEASE SHOW PANEL "C" ON | | | ELECTRICAL PLANS PER 215-5. NOTE 110-26 | | | FOR CLEARENCES ABOUT POOL EQUIPMENT. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-10-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-10-07 |
Time |
14:03 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-10-07 |
Time |
14:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-27 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-27 |
Time |
09:58 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-10-27 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2000-11-02 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-11-02 |
Time |
15:25 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-11-02 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ************BUILDING PROVISO************ | | | | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR ALL EXTERIOR SWING ENTRY DOORS. | | | | | | 2)PROVIDE RAISE SEAL AND ORIGINAL DATE | | | AND SIGNATURE OF ARCHITECT AND ENGINEER | | | ON NORANDEX PRODUCT APPROVAL FORM FOR | | | WINDOWS, MULLIONS, AND SLIDING GLASS | | | DOORS WITH JOB SITE LOCATION. | | | | | | 3)PROVIDE BUTT GLASS ENGINEERING. | | | | | | PLEASE SUBMIT PRIOR TO INSTALLATION. | | | | | | 4)PROVIDE STORM PANEL INFORMATION UNDER | | | SEPARATE PERMIT. | | | | | | 5)PROVIDE NOC BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | 6)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-09-27 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-09-27 |
Time |
17:45 |
Rev Time |
0.15 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |