| Plan Review Stops For Permit 00091125 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-11 |
Time |
20:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-11 |
Time |
20:34 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-22 |
Time |
20:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-22 |
Time |
20:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-05 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-05 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SHOW CLARIFICATION OF NEW | | | PANEL BEING INSTALLED. YOU SHOW MLO AND | | | 60A ? IS THIS GOING TO HAVE A 60 AMP | | | BRKER FOR THE MAIN? IF NOT THEN A MAIN | | | IS REQ`D AT DETACHED STRUCTURE. | | | | | | 2)NOTE: PLEASE SHOW GROUNDING ATTACHMENT | | | AT THE DETACHED STRUCTURE. BLDG/SLAB | | | STEEL AND COLD WATER BOND. PER 250-50 | | | | | | 3)NOTE: PLEASE SEE CONDUCTOR SIZE SHOWN | | | AS EXISTING FOR 200AMP SERVICE??? #1 IS | | | NOT LARGE ENOUGH FOR 200A SERVICE. | | | PLEASE SUBMIT CLARIFICATION. IF #1 THEN | | | MAIN SERVICE CONDUCTORS WILL BE REQ`D TO | | | BE BROUGHT UP TO CODE. | | | | | | 4)NOTE: PLEASE SEE NFPA-72 2-2.1.1.1 | | | SMOKE DETECTORS ARE REQ`D INSIDE AND | | | OUTSIDE ASLL SLEEPING ROOMS.THIS INCLUDE | | | -S CABANA, AS IT HAS A CLOSET AND BATH | | | FOR SLEEPING ROOM CONVERSION. | | | ALL MUST BE WIRED INLINE. | | | | | | 5)NOTE; PLEASE PROVIDE PANEL SCHEDULES | | | FOR EXISTING AND NEW PANEL. PLEASE LIST | | | THE REQ`D BATH(S) CIRCUIT(S) PER 210-52D | | | AND 210-11-C-3. MUST BE #12 AWG AND 20A. | | | | | | 6)NOTE: PLEASE NOET MISSING OUTLET FOR | | | NEW SECOUND FLOOR BATH REQ`D BY 210-52D | | | | | | 7)(NOTE: PLEASE NOTE MISSING EGRESS | | | LIGHT REQ`D FOR CABANA PER 210-70. | | | | | | 8)NOTE: PLEASE NOTE ELECTRICAL PANEL | | | SHOWN IN CABANA CLOSET. THIS IS NOT | | | PERMITTED IN CLOSET SPACE PER 110-26F | | | AND 384-7 FOR ELECTRICAL EQUIPMENT BEING | | | INSTALLED AROUND IGNITABLE MATERIALS. | | | | | | 9)NOTE: PLEASE CLARIFY 240/1%%C SHOWN ON | | | BOTTOM OF LOAD CALCULATIONS. (TYPE-O)??? | | | | | | 10)NOTE: SPACE HEATER SHOWN ON LOAD | | | CALCULATIONS FOR CABANA? NOT SHOWN ON | | | ELECTRICAL FLOOR PLAN???? PLEASE CALRIFY | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THEREARE ANY QUESITONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-10-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-10-07 |
Time |
07:03 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-10-07 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C PLAN | | | A/C CONTRACTOR MUST SUBMIT PLANS WITH | | | APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-12-17 |
Time |
13:01 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2001-12-17 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2001-12-17 00:00:00 | NO GAS WATER HEATER AT THIS HOUSE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-12-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-15 |
Time |
16:53 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-15 00:00:00 | PLUMBING PLAN REVIEW,DENIED | | | SEE ATTACHED GAS PERMIT REQUIRMENTS, | | | ADDRESS EA CIRCLED COMMENT,1,2,3,4,5,6, | | | 7,8,9,SEPERATEGAS PERMITREQUIRED. | | | END OF COMMENTSPAUL SCHMITZ | | | 561-659-8096X8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-11 |
Time |
20:34 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2001-01-20 |
Time |
09:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-10-10 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-10 |
Time |
17:17 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-10-10 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)FIXTURES DOWNSTREAM OF WATER CLOSETS | | | SHALL BE VENTED PER SPC SEC.913.2. | | | | | | 2)FIXTURE BRANCHES NOT PERMITTED ON WET | | | VENT PER COUNTYWIDE AMENDMENTS TO SPC | | | SEC.911.1.1.(RISER FOR 2ND.FLR.BATH TO | | | CONNECT TO HORIZONTAL DRAIN DOWN- | | | STREAM OF EXISTING WATER CLOSET.) | | | | | | 3)A MAX.OF 2 WATER CLOSETS ARE PERMITTED | | | ON A 3" BUILDING DRAIN.SPC TABLE 714.1, | | | FOOTNOTE #3 | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-01-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-01-25 |
Time |
15:56 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2001-01-25 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2001-01-25 00:00:00 | APPROVED WITH PROVISO: | | | 1-PROVIDE ENERGY CALCULATIONS. | | | 2-PROVIDE PRODUCT APPROVAL FOR: | | | -METAL ROOF (MISSING PAGE 3 OF 5 AND | | | DRAWINGS ARE NOT LEGIBLE). | | | -WINDOW MULLIONS. | | | -CURRENT PRODUCT APPROVAL FOR DOUBLE | | | HUNG WINDOWS. ALONG WITH DRAWINGS. | | | 3-UNVENTED ATTIC AS ALTERNATE MATERIALS | | | AND METHODS, SECTION 103.7 OF CITY | | | AMENDMENTS TO SBC 1997. | | | -PROVIDE COMPLETE SET OF DETAILS AND | | | SPECIFICATIONS SHOWING SYSTEM/ASSEMBLY | | | OF UNVENTED ATTIC. SIGNED,SEALED AND | | | DATED. | | | 4-MECHANICAL, ELECTRICAL, PLUMBING AND | | | ROOFING CONTRACTORS TO PULL OUT THEIR | | | OWN PERMITS. | | | | | | | | | | | | | | | | | | | | | NOTES: | | | -PROVIDE ALL INFORMATION REQUESTED ON | | | THIS PROVISO PRIOR TO CONSTRUCTION OR | | | INSTALLATION IN ORDER TO AVOID DELAYS | | | OR CONFLICTS. | | | -IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 659-8096 EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-10-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-10-20 |
Time |
14:26 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2000-10-20 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. | | | BRING STAMPED DRAWINGS AND RECEIPT. | | | 2-SPECIFY SAFETY GLASS WHERE REQUIRED. | | | SEE PLANS. SECTION 2405.2 SBC 1997. | | | 3-PROVIDE ATTIC ACCESS AT SECOND FLOOR | | | ROOF. SECTION 2309.6 SBC 1997. | | | 4-PROVIDE CURRENT SURVEY WITH NEW BLDG | | | LAYOUT. SIGNED AND SEALED. | | | 5-PROVIDE PRODUCT APPROVAL FOR: | | | -FLAT ROOF SYSTEM. | | | -METAL ROOF (MISSING SHEET 3 OF 5 AND | | | APPROVED DRAWINGS AREN'T LEGIBLE). | | | -DOUBLE FRENCH DOORS. | | | -OUTSWING & INSWING SINGLE FRENCH DOORS | | | -WINDOW MULLIONS. | | | -DOUBLE HUNG WINDOWS (PRODUCT APPROVAL | | | EXPIRED AND NEED COPIES OF APP'D DWGS) | | | -PROVIDE EXTRA COPY OF CASEMENT WINDOWS | | | 6-EGRESS WINDOWS AT SECOND FLOOR BEDRMS | | | DON'T COMPLY WITH SECTION 1005.4.4 OF | | | SBC 1997. | | | 7-SPECIFY ATTIC VENTILATION AS PER SEC. | | | 2309.7 SBC 1997. | | | 8-STORM PANELS: | | | -PROVIDE A COMPLETE INSTALLATION SCHED. | | | AS PER CITY SAMPLE ATTACHED AND A KEY | | | PLAN. | | | -CIRCLE/HIGHLIGHT SPECIFIC MOUNTING | | | CONDITIONS AND ANCHOR TYPE AND SPACING | | | TO BE USED ACCORDING TO THE MEAN ROOF | | | HEIGHT, DESIGN PRESSURES, PANEL SPAN, | | | EDGE DISTANCE AND CONNECTION TYPE. | | | 9-PROVIDE FRAMING DETAILS AT NEW DOORS | | | AND WINDOWS AND SPECIFY HOW OPENINGS | | | ARE REINFORCED TO RECEIVE THE STORM | | | PANELS. | | | 10-SEE PLANS FOR ADDITIONAL COMMENTS, | | | INCLUDING THOSE BY THE OTHER TRADES. | | | | | | | | | NOTES: | | | -PLEASE RETURN REVIEWED SET AFTER THE | | | CORRECTIONS ARE DONE TO THE ORIGINAL | | | DRAWINGS IN ORDER TO EXPEDITE THE | | | REVIEW PROCESS. | | | -IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ (BUILDING PLAN REVIEWER) AT | | | 659-8096 EXT. 8232. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-09-27 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-09-27 |
Time |
16:57 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|