| Plan Review Stops For Permit 00091111 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-04-10 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2001-04-10 |
Time |
09:45 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
2001-04-10 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2001-04-10 00:00:00 | REVISIOR ISSUED WRS 4/10/01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-11-22 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-22 |
Time |
15:50 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-11-22 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-10-24 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-10-24 |
Time |
15:02 |
Rev Time |
2.00 |
| Received By |
drunnels |
Date |
2000-10-24 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. DEAD END CORRIDORS OVER 20 FEET IN | | | LENGTH ARE NOT ALLOWED/SECTION 1005.2 | | | 1997 EDITION SBC | | | 2. TENNANT SPACES ARE REQUIRED TO HAVE 2 | | | MEANS OF EGRESS/ SECTION 1004.1.2 1997 | | | EDITION SBC | | | 3. ALL COMBUSTIBLES IN CONCEALED SPACES | | | SHALL COMPLY WITH SECTION 707 | | | 1997 EDITION SBC |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-17 |
Time |
22:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-17 |
Time |
22:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-03-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-13 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-13 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-10-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-24 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-24 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2001-09-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-27 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-27 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-04-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-06 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-06 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-03 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-03 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2000-10-24 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-24 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-24 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) PROVIDE A SECOND MEANS OF EGRESS FROM | | | TENANT SPACE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-10-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-06 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-06 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-03-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-26 |
Time |
12:26 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-03-26 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2001-03-26 00:00:00 | REVISION - | | | | | | CHANGED CONFERENCE RM., CORRIDOR AND | | | RECEPTION AREA TO HARD CEILINGS.NOTE | | | 15 ON DRAWING AC-1 INDICATES ACCESS | | | PANELS TO BE INSTALLED WHERE NEEDED. | | | CHANGED DROPS IN THESE AREAS TO LINEAR | | | DIFFUSERS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-10-21 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-10-21 |
Time |
08:00 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-10-21 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-09-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-26 |
Time |
11:53 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
2000-09-26 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *******************PROVISO************** | | | SINK IN COFFEE ROOM #102 SHALL COMPLY | | | W/FACBC SEC.4.24.1-4.24.7. | | | | | | CALL 561659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|