Plan Review Details - Permit 00091035
Plan Review Stops For Permit 00091035
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-11-22 Cont ID  
Sent By dpalmer Date 2000-11-22 Time 08:18 Rev Time 0.00
Received By dpalmer Date 2000-11-22 Time 08:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-05-31 Cont ID  
Sent By hmoser Date 2001-05-31 Time 17:53 Rev Time 0.50
Received By hmoser Date 2001-05-31 Time 17:51 Sent To  
Notes
2001-05-31 00:00:00REVISON COMPLETE IN BIN I

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-10-07 Cont ID  
Sent By jleech Date 2000-10-07 Time 14:46 Rev Time 0.50
Received By jleech Date 2000-10-07 Time 14:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-11-22 Cont ID  
Sent By jleech Date 2000-11-22 Time 09:53 Rev Time 0.33
Received By jleech Date 2000-11-22 Time 09:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-09-28 Cont ID  
Sent By tlarge Date 2000-09-28 Time 07:35 Rev Time 1.00
Received By tlarge Date 2000-09-28 Time 07:35 Sent To  
Notes
2001-01-08 00:00:001)SHT.A-1-NOTE #7-SHOWER HEADS SHALL BE
 LIMITED TO A MAX.OF 2.5GPM PER F.E.C.
 SEC.612.1.ABC.2.4.
  
 2)DRY VENTS NOT PERMITTED PER SPC SEC.
 906.2.1.
  
 3)LOCATION OF FIXTURES SHALL NOT INTER-
 FERE W/THE OPERATION OF DOORS,WINDOWS,
 ETC.PER SPC SEC.404.2.SEE M.B.,POWDER
 ROOM AND CABANA BATH.
  
 4)PLEASE PUT CALCULATIONS FOR COMBUSTION
 AIR ON THE PLANS,NOT ON THE MANUF.SHEETS
 CALCULATIONS SHALL BE DONE BY THE DESIGN
 PROFESSIONAL.COUNTYWIDE AMENDMENTS TO
 SPC SEC.104.2.3.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop R ROOF PLAN REVIEW
Rev No 9 Status P Date 2002-07-31 Cont ID  
Sent By jgomez Date 2002-07-31 Time 17:46 Rev Time 0.00
Received By jgomez Date 2002-07-31 Time 17:46 Sent To  
Notes
2002-07-31 00:00:00BUTT GLAZING ENGINEERED ASSEMBLY.

Review Stop R ROOF PLAN REVIEW
Rev No 8 Status F Date 2002-07-25 Cont ID  
Sent By jgomez Date 2002-07-25 Time 18:09 Rev Time 0.00
Received By jgomez Date 2002-07-25 Time 18:09 Sent To  
Notes
2002-07-25 00:00:00BUTT GLAZING ASSEMBLY:
 A)ENGINEER NEEDS TO PROVIDE COMPLETE
 ENGINEERED ANALYSIS FOR THE COMPLETE
 SITE SPECIFIC ASSEMBLY AS SHOWN ON THE
 ARCHITECTURAL DRAWINGS. SEE SECTIONS
 2406.1 FOR DEFLECTION CALCULATIONS AND
 SECTION 2406.2 FOR INFORMATION REQ'D
 TO BE SUBMITTED BY THE ENGINEER.
 B)ENGINEER TO PROVIDE COMPLETE SPECS FOR
 SILICONE TO BE USED INCLUDING AT SIDE
 WHERE GLASS IS BUTT TOGETHER.
 C)THICKNESS OF GLASS SPECIFIED BY THE
 ENGINEER DOESN'T MATCH THICKNESS SHOWN
 ON PRODUCT APPROVAL FOR KDI 2000 FIXED
 GLASS IMPACT WINDOW.
 D)PROVIDE COPIES OF APPROVED DRAWINGS
 FOR KDI 2000 FIXED GLASS IMPACT WINDOW
  
 REMAINDER:
 ARCHITECT TO REVIEW ASSEMBLY PRIOR TO
 SUBMITTAL.
  
  
 SUGGESTION:
 SEE SITE SPECIFIC ENGINEERING PACKAGE
 SUBMITTED FOR ENTRY DOOR AS A SAMPLE OF
 INFORMATION REQUIRED TO BE SUBMITTED.

Review Stop R ROOF PLAN REVIEW
Rev No 7 Status F Date 2002-07-19 Cont ID  
Sent By jgomez Date 2002-07-19 Time 13:15 Rev Time 0.00
Received By jgomez Date 2002-07-19 Time 13:15 Sent To  
Notes
2002-07-19 00:00:00CHECKLIST:
 1-BUTT GLAZING ASSEMBLY:
 A)INFORMATION SUBMITTED DOESN'T SATISFY
 REQUIREMENTS OF SEC. 2406.2 SBC 1997
 AS REQUESTED ON PREVIOUS CHECKLIST.
 **"DETAILED SHOP DRAWINGS,SPECIFICATIONS
 AND RATIONAL ANALYSIS AND/OR TEST DATA
 ASSURING SAFE PERFORMANCE FOR THE
 SPECIFIC INSTALLATION SHALL BE
 PREPARED BY ENGINEERS EXPERIENCED IN
 THIS WORK AND SHALL BE SUBMITTED FOR
 AND RECEIVE, IF WARRANTED, FORMAL
 APPROVAL BY THE BUILDING OFFICIAL."
 B)INFORMATION SUBMITTED IS CROSS
 MATCHING TWO DIFFERENT CODES STANDARD
 BUILDING CODE AND FLORIDA BUILDING
 CODE. ALSO, NEED TO SPECIFY THE YEAR
 OF THE CODE USED.
 C)DESIGN PRESSURES SPECIFIED DON'T MATCH
 THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT.
 D)MEAN ROOF HEIGHT IS INCORRECT. ENG'R
 NEEDS TO SEE ARCHITECT'S PLANS TO
 PROPERLY DESIGN SITE SPECIFIC ASSEMBLY
 E)WHERE IS THE ATTACHED SPECIFICATION
 MENTIONED ON ENGINEER LETTER?
  
 2-SUBMITTED PRODUCT APPROVAL FOR FIXED
 WINDOWS IS FOR RECTANGULAR WINDOWS NOT
 FOR ARCHED WINDOWS. THIS PRODUCT
 APPROVAL WAS ALREADY SUBMITTED FOR THE
 RECTANGULAR WINDOWS AND IT WAS BY PGT
 WINDOWS NOT BY K.D WINDOWS. CLARIFY,
 WHICH ONE WAS INSTALLED.
  
 3-ARCHITECT TO REVIEW AND APPROVE SITE
 SPECIFIC ASSEMBLY PRIOR TO SUBMITTAL.
  
 NOTE: PRODUCT APPROVAL FOR FRENCH DOORS
 WITH SIDELITES IS OK.

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status F Date 2002-06-03 Cont ID  
Sent By jgomez Date 2002-06-03 Time 10:57 Rev Time 0.25
Received By jgomez Date 2002-06-03 Time 10:57 Sent To  
Notes
2002-06-03 00:00:001-THE FOLLOWING PRODUCT APPROVALS WERE
 NEVER SUBMITTED FOR REVIEW:
 A)FRENCH DOORS WITH SIDELITES SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 B)ARCHED WINDOWS AS SHOWN ON PLANS.
 C)BUTT GLAZING ASSEMBLY AS SHOWN ON
 PLANS.
 **NOTE:
 PROVIDE COMPLETE INFORMATION BY
 SPECIALTY ENGINEER AS REQUIRED BY
 SECTION 2406.2 SBC 1997.
 **REMAINDER:
 ARCHITECT OF RECORD TO REVIEW THEM AS
 DONE WITH SITE SPECIFIC PRODUCT
 APPROVAL FOR ENTRY DOOR ASSEMBLY.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status F Date 2002-05-31 Cont ID  
Sent By jgomez Date 2002-05-31 Time 16:50 Rev Time 1.00
Received By jgomez Date 2002-05-31 Time 16:50 Sent To  
Notes
2002-05-31 00:00:00THE FOLLOWING ITEMS REQUESTED ON PROVISO
 DATED 11-29-00 WERE NEVER SUBMITTED FOR
 REVIEW:
 A)

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2002-05-03 Cont ID  
Sent By jgomez Date 2002-05-03 Time 13:35 Rev Time 1.50
Received By jgomez Date 2002-05-03 Time 13:35 Sent To  
Notes
2002-05-03 00:00:00CHECKLIST:
 1-INFORMATION REQUESTED ON PROVISO DATED
 11-29-00 WAS NEVER SUBMITTED FOR
 REVIEW.
 2-SUBMITTAL FOR SITE SPECIFIC PRODUCT
 APPROVAL FOR ENTRY DOORS ASSEMBLY:
 A)INFORMATION DOESN'T MATCH BUILDING
 CODE USED BY ARCHITECT WHO DESIGNED
 THE BUILDING.(SBC 1997 NOT FBC 2001).
 B)DESIGN PRESSURES USED DON'T MEET THE
 DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT.
 C)AS PER BLDG OFFICIAL: SITE SPECIFIC
 INSTALLATIONS REQUIRES PROFESSIONAL OF
 RECORD TO REVIEW "PRODUCT APPROVAL"
 ENGINEERING INFORMATION AND CERTIFY
 (SIGNED AND SEALED) THAT SUCH PRODUCT
 WILL BE STRUCTURALLY ADEQUATE TO BE
 INSTALLED IN THE STRUCTURE HE DESIGNED
 D)WRONG PROJECT ADDRESS. REVISE AS REQ'D
 NOTE: ENGINEER'S CALCULATIONS SHOW THAT
 HE CONSIDERS DOOR ASTRAGAL AND DEAD
 BOLT TO SATISFY HIS CALCULATIONS.
 NEED TO CHECK THAT THIS LOCKS WILL
 COMPLY WITH EGRESS REQUIREMENTS TO
 AVOID CONFLICTS.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-01-18 Cont ID  
Sent By jgomez Date 2001-01-18 Time 14:15 Rev Time 1.00
Received By jgomez Date 2001-01-18 Time 14:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-11-29 Cont ID  
Sent By jgomez Date 2000-11-29 Time 11:13 Rev Time 3.50
Received By jgomez Date 2000-11-29 Time 11:12 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE FRAMING DETAILS FOR
 CUPOLAS.CLEARLY SPECIFY ALL CONNECTORS
 AND FRAMING AROUND ARCHED WINDOWS.
 SEC. 104.2.2 CITY AMENDMENTS.
 2-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM: THE
 MEAN ROOF HEIGHT AND BASIC VELOCITY
 PRESSURE DON'T MATCH. SEE TABLE
 1606.2A OF SBC 1997.
 3-SOIL TEST REPORT SHOWS THE PRESENCE OF
 ROOTS AND ORGANIC MATERIALS. THE AREA
 UNDER FOOTINGS, FOUNDATIONS AND
 CONCRETE SLABS ON GRADE SHALL HAVE ALL
 VEGETATION, STUMPS, ROOTS AND FOREIGN
 MATERIALS REMOVED PRIOR TO CONSTRUCT'N
 SECTION 1804.1.8 SBC 1997.
 4-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOORS: 3"-0" BY 9'-0" WITH
 SIDELITES ASSEMBLY.
 B)FRENCH DOORS WITH SIDELITES ASSEMBLY.
 C)ARCHED WINDOWS
 D)COMPLETE BUTT GLAZING ASSEMBLY.
 5-PROVIDE COMPLETE INFORMATION FOR GLASS
 MISSILE IMPACT PROTECTION FOR THIS
 HOUSE. EG: PROVIDE A KEY PLAN SHOWING
 AREAS TO HAVE IMPACT GLAZING AND AREAS
 TO HAVE ANY OTHER PROTECTION.
 -PROVIDE COMPLETE INFORMATION FORSUCH
 OTHER METHOD OF PROTECTION.
 6-SEE PLANS FOR ADDITIONAL COMMENTS.
  
  
  
 NOTES-
 -IF YOU HAVE ANY QUESTIONS PLEASE CALL
 JULIO GOMEZ, BUILDING PLAN REVIEW, AT
 659-8096 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-10-24 Cont ID  
Sent By jgomez Date 2000-10-24 Time 16:11 Rev Time 4.50
Received By jgomez Date 2000-10-24 Time 16:11 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS. SECTION 2405.2 SBC 1997.
 3-ARCHITECT NEEDS TO DATE DRAWINGS WHEN
 SIGNING AND SEALING DOCUMENTS FOR
 PUBLIC RECORDS. CHAPTER 481 OF FLORIDA
 STATUTES.
 4-SPECIFY THE CALCULATED DESIGN PRESSURE
 FOR GARAGE DOORS. SECTION 1606 SBC/97.
 5-PROVIDE ATTIC ACCESS AT MASTER BATH
 CUPOLA, ENTRY TOWER, AND COVERED REAR
 PATIO. SECTION 2309.6 SBC 1997.
 6-PROVIDE A COMPLETE BATHROOM WITH A
 DOOR THAT ALLOWS 29" MINIMUM CLEAR
 OPENING. SECTION 11 OF FLORIDA
 ACCESSIBILITY CODE FOR BUILDING
 CONSTRUCTION, 1997 EDITION.
 7-PROVIDE COMPLETE FRAMING DETAILS FOR
 CUPOLAS.CLEARLY SPECIFY ALL CONNECTORS
 SECTION 104.2.2 CITY AMENDMENTS TO SBC
 8-CLEARLY AND COMPLETELY SPECIFY THE
 CEILING CONSTRUCTION AT FRONT AND
 BACK PORCHES. CLEARLY SPECIFY ALL
 MATERIALS AND FASTENER TYPE & SPACING.
 SECTION 2504.2 SBC 1997.
 9-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM.
 THE MEAN ROOF HEIGHT IS INCORRECT.
 10-SPECIFY SIZE OF CEILING FANS AS PER
 TABLE 6-6 OF FLORIDA ENERGY EFFICIENCY
 CODE FOR BUILDING CONSTRUCTION. 1997.
 11-SOIL TEST REPORT SHOWS BORINGS TESTS
 WITH ROOTS. CLEARLY ADDRESS HOW ARE
 THE ROOTS GOING TO BE REMOVED.
 SECTION1804.1.8 SBC 1997.
 12-PROVIDE PRODUCT APPROVALS FOR:
 -ENTRY DOORS 3'-0" BY 9'-0" HIGH AND
 WITH SIDELITES ASSEMBLY.
 -BBQ AND HOOD UL LISTING AND SPECS.
 -FRENCH DOORS WITH SIDELITES.
 -ARCHED WINDOWS(MISSILE IMPACT GLAZING)
 -BUTT GLAZING ASSEMBLY.
 13-PROVIDE ADDITIONAL INFORMATION FOR
 MISSILE IMPACT PROTECTION FOR GLASS
 OPENINGS NOT COVERED IN THIS SUBMITTAL
 UNDER A SEPARATE PERMIT.
 14-SEE PLANS FOR ADDITIONAL COMMENTS.
  
  
  
  
  
  
 NOTES:
 -PLEASE RETURN REVIEWED SET AFTER
 CORRECTION ARE DONE TO ORIGINALS IN
 ORDER TO EXPEDITE THE REVIEW PROCESS.
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-09-27 Cont ID  
Sent By gjoyce Date 2000-09-27 Time 10:31 Rev Time 0.15
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***