Plan Review Details - Permit 00090956
Plan Review Stops For Permit 00090956
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-01-26 Cont ID  
Sent By jwitmer Date 2001-01-26 Time 14:18 Rev Time 2.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-12-19 Cont ID  
Sent By hpiskura Date 2000-12-19 Time 13:18 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00LETTER W/APPLICATION

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-10-14 Cont ID  
Sent By lmartine Date 2000-10-14 Time 11:53 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00BUILDING COMMENTS
 -------------------
  
 1] ADDITIONAL FEES DUE,IMPACT AND RADON.
 2] SURVEY SHOWS WATER METER TO BE CLOSED
 IN BY CONSTRUCTION,PLEASE EXPLAIN.
 3] PLAN CALLS FOR A NEW SKYLIGHT,SUBMIT
 INSTALLATION AND IMPACT PROTECTION
 INFORMATION.
 4] WIND LOAD CERTIFICATE FOR ROOF SYSTEM
 SHALL BE SIGNED SEALED AND REVISED
 TO INCLUDE AN ENCLOSED MASONRY STRUCT-
 URE.
 5] VERIFY FINAL INSPECTION FOR EXISTING
 ROOF,PERMIT#98090643.
 6] PLANS CALL FOR DIFFERENT OPENING SIZE
 AT OVERHEAD DOOR,VERIFY 12'OR 16'.
 7] STOREFRONT SYSTEM REPORT IS MISSING
 MANUFACTURES SPECS, #4500-100.
 8] PROVIDE SECOND COPY OF REPORTS #98-
 1026.03 AND 97-0423.05.
 9] PROVIDE ROOF DRAINAGE PLAN,INCLUDE
 MIN. PITCH PER FT.
 10] PROVIDE SPECS ON ROOF COVER TO MEET
 CLASS "A" OR "B"CLASSIFICATION.
 11] DETAIL R-1 SPECIFYS ROOF CONNECTION
 AND 2X2 POST,PLAN CALLS FOR MASONRY
 WALL.
 12] SUBMIT ELEVATIONS TO CALCULATE TABLE
 600 ALLOWABLE OPENINGS AND PROVIDE
 LISTED ASSEMBLY FOR 3HR. WALLS.
 13] PLANS SUBMITTED INDICATE MORE WORK
 THAN APPLICATION STATES,PLEASE
 CLERIFY.
 14] SUBMIT EGRESS PLAN,LIFE SAFETY.
 15] PROVIDE ENGINEERING AT GARAGE DOOR
 COLUMNS, WILL 1#5 BE SUFFICIENT?
  
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 659-8096
 EXT. 8456

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-01-26 Cont ID  
Sent By dpalmer Date 2001-01-26 Time 14:49 Rev Time 0.00
Received By dpalmer Date 2001-01-26 Time 14:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-12-11 Cont ID  
Sent By dpalmer Date 2000-12-11 Time 20:11 Rev Time 0.00
Received By dpalmer Date 2000-12-11 Time 20:11 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASE SUBMIT PLANS SHOWING ALL
 BRANCH CIRCUIT #`S ON PLAN AND CORRELATE
 WITH PANEL SCHEDULE.
  
 2)NOTE: PLEASE SHOW ALL TRACK LIGHTING
 CALCULATIONS PER 220-12B.
  
 3)NOTE: PLEASE SEE PANEL SCHEDULE AND
 RISER DIAGRAM. ONE SHOWS 4/0 AND THE
 OTHER SHOWS 3-#4`S. PLEASE CORRECT.
  
 4)NOTE: PLEASE SHOW ALL CONTINOUS LOADS
 AT 125% (LIGHTING) ETC.
  
 5)NOTE: PLEASE CLARIFY OUTLETS SHOWN AS
 C.O.?
  
 6)NOTE: PLEASE SHOW ALL THE REQ`MENTS
 FOR SPRAY BOOTH PER 516-2. PLEASE
 PROVIDE CLEARENCES ON PLANS.
  
 7)NOTE: PLEASE CLARIFY THE REQ`D SHOW
 WINDOW OUTLETS PER 210-62
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-10-25 Cont ID  
Sent By dpalmer Date 2000-10-25 Time 01:39 Rev Time 0.00
Received By dpalmer Date 2000-10-25 Time 01:39 Sent To  
Notes
2001-01-08 00:00:00*(**************** UNSAT ***************
  
 1)NOTE: PLEASE SUBMIT ELECTRICAL AND
 MORE DETAIL ON WORK BEING DONE AND/OR
 ELECTRCIAL BEING INSTALLED,
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL,
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096- EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-01-26 Cont ID  
Sent By mcarsill Date 2001-01-24 Time 11:20 Rev Time 0.00
Received By mcarsill Date 2001-01-24 Time 11:20 Sent To  
Notes
2001-01-24 00:00:00ON JANUARY 24, 2001, WRITER CALLED STEVE
 ANNUNZATA, TELEPHONE NUMBER 906-9300.
 HE CALLED WRITER BACK. ACCORDING TO
 MR. ANNUNZATA, THE BUILDING WILL BE
 USED FOR STORAGE, AND IS A SINGLE TENANT
 ARRANGEMENT. HE WAS ADVISED THAT THE
 DOUBLE DOORS AND THE EXIT SIGN WOULD
 NEED TO BE RELOCATED TO MEET THE
 MAXIMUM TRAVEL DISTANCE OF 50 FEET TO
 REACH AN EXIT IN AN UNSPRINKLERED
 STORAGE OCCUPANCY. HE ADVISED THAT HE
 WOULD CONTACT THE ARCHITECT TO RED-LINE
 THE DRAWINGS. ON JANUARY 26, 2001,
 STEPHEN SINCLAIR CAME TO CITY HALL AND
 RED-LINED THE DRAWINGS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2000-12-20 Cont ID  
Sent By mcarsill Date 2000-12-20 Time 10:53 Rev Time 0.00
Received By mcarsill Date 2000-12-20 Time 10:53 Sent To  
Notes
2001-01-08 00:00:001) PLANS DID NOT INDICATE IF SPRAY
 BOOTH SHOWN IS NEW OR EXISTING. DETAILS
 PROVIDED FOR SPRAY BOOTH DID NOT
 INDICATE FIRE SPRINKLER PROTECTION OR
 OTHER SUPPRESSION TYPE EQUIPMENT AS
 REQUIRED BY FIRE CODES.
 2) ELECTRICAL PLAN SHOWS ONLY ONE MEANS
 OF EGRESS.
 3) PROVIDE DETAILS ON SPRAY BOOTH
 DUCT REQUIREMENTS.
 4) MORE DETAILS NEEDED TO PERFORM PLAN
 REVIEW.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-10-24 Cont ID  
Sent By mcarsill Date 2000-10-24 Time 12:31 Rev Time 0.00
Received By mcarsill Date 2000-10-24 Time 12:31 Sent To  
Notes
2001-01-08 00:00:001) PLEASE PROVIDE MORE DETAILS ON SPRAY
 BOOTH. IS SPRAY BOOTH EXISTING OR NEW.
 PLEASE BE ADVISED THAT SPRAY BOOTHS ARE
 TO COMPLY WITH ALL REQUIREMENTS AS
 OUTLINED IN NFPA 33, THE STANDARD FOR
 SPRAY APPLICATIONS USING FLAMMABLE AND
 COMBUSTIBLE LIQUIDS.
 2) AWNINGS IF CANVAS ARE TO BE FLAME
 RETARDANT.
 3) PLEASE INDICATE ALL EXIT DOORS,
 EXIT SIGNS AND EMERGENCY LIGHTING
 APPLIANCES.
  
 PLANS REVIEWED BY CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-12-14 Cont ID  
Sent By ndenmark Date 2000-12-14 Time 12:28 Rev Time 0.33
Received By ndenmark Date 2000-12-14 Time 12:28 Sent To  
Notes
2001-01-08 00:00:00PAINT SPRAY BOOTH REQUIRES SEPARATE
 MECHANICAL PERMIT. SUBMIT COMPLETE PLANS
 SHOWING COMPLIANCE WITH APPLICABLE CODES
 AT TIME OF PERMIT APPLICATION FOR BOOTH
 PRIOR TO ANY WORK STARTING ON BOOTH.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-10-04 Cont ID  
Sent By gjoyce Date 2000-09-27 Time 10:16 Rev Time 0.15
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00DID NOT PASS HPB