2001-01-08 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE PROVIDE MORE ELECTRICAL
 DETAIL REQ`D FOR MEANS OF EGRESS LIGHT-
 -ING PER 210-70 FROM MAIN HOUSE INTO
 NEW ADDITION, FROM NEW ADDITION TO
 OUTSIDE.
  
 2)NOTE: REQ`D BY 210-52EGFI REC AT
 REAR OF HOUSE.
  
 NOTE: ARE THERE GOING TO BE ANY TV/TELE-
 -PHONE OUTLETS?????
 PLEASE DRAW IN THE SWITCHING FOR ALL
 LIGHTING.
  
  
 PLEASE SUBMIT THE ABOVE INFORMAITON FOR
 REVIEW. IF THEREARE ANY QUESTIONS
 PLEASE CALL
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-11-20 Cont ID  
Sent By jleech Date 2000-11-20 Time 18:32 Rev Time 0.25
Received By jleech Date 2000-11-20 Time 18:31 Sent To  
Notes
2001-01-08 00:00:00NO A/C PLAN. SUBMIT PLAN WHEN MAKE
 APPLICATION FOR A/C PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-11-22 Cont ID  
Sent By rmcdouga Date 2000-11-22 Time 13:36 Rev Time 0.00
Received By rmcdouga Date 2000-11-22 Time 15:02 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)PROVIDE PRODUCT APPROVALS FOR ROOF
 COVERING UNDER SEPARATE PERMIT.
  
 2)PROVIDE SOIL COMPACTION TEST AT FIRST
 INSPECTION.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-10-12 Cont ID  
Sent By rmcdouga Date 2000-10-12 Time 13:39 Rev Time 3.00
Received By rmcdouga Date 2000-10-12 Time 16:24 Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY, PLANS STAMPED BY THEM AND COPY
 OF RECEIPT SUBMITTED TO CITY OF W.P.B.
 BUILDING DEPT. BEFORE A PERMIT TO
 CONSTRUCT WILL BE ISSUED.
  
 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 STEEL DOOR. APPROVAL THAT WAS SUBMITTED
 HAD EXPIRED.
  
 3)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR ROOFING
 MATERIAL AND STORM PANELS.
  
 4)MISSLE IMPACT PROTECTION IS REQUIRED
 ON ALL EXTERIOR WINDOWS. CITY AMENDMENTS
 TO 97 SBC.
  
 5)PROVIDE SPACING AND TYPE OF WOOD THAT
 WILL BE USED FOR RAFTERS. SPECIFY TYPE
 OF CONNECTORS (HURRICANE STRAPS) THAT
 WILL BE USED TO ANCHOR RAFTERS TO TIE
 BEAM AT NEW AND EXISTING WALLS.
  
 6)INDICATE ON PLANS TIE BEAMS, COLUMNS
 (FILLED CELLS), LINTELS THAT WILL BE
 USED. INCLUDE THE NUMBER AND SIZE OF
 REINFORCING STEEL.
  
 7)INDICATE ON PLANS HOW NEW WALLS,TIE
 BEAMS AND FOUNDATION WILL BE CONNECTED
 TO EXISTING.
  
 8)INDICATE TYPE OF FURRING THAT WILL BE
 USED ON BLOCK WALLS. PROVIDE FIRE BLOCK-
 ING WHERE WALLS MEET CEILING.
  
 9)IF ADDITION IS TO BE MECHANICALLY
 HEATED OR COOLED,PROVIDE ENERGY
 CALCULATIONS INCLUDING MANUAL"J" CALCS.
 PER 97 FL ENERGY EFFICIENCY CODE.
  
 10)INDICATE ON PLANS TYPE AND R VALUE OF
 INSULATION FOR WALLS AND CEILINGS.
  
 11)PROVIDE ATTIC VENTILATION PER 97 SBC
 SEC. 2309.7
  
 12)ASPHALT SHINGLES REQUIRE A MINIMUM
 2:12 PITCH PER 1504.2 97 SBC. INDICATE
 ROOF COVERING APPLICABLE TO A FLAT ROOF.
  
 13)PROVIDE DETAILS OF WINDOW AND DOOR
 BUCK CONNECTIONS.
  
 14)PROVIDE FLOOR PLAN OF EXISTING HOUSE
 INDICATING LOCATION OF BEDROOMS AND DOOR
 & WINDOW OPENINGS AND SIZES. THIS INFO
 IS NEEDED TO DETERMINE EGRESS AND
 PERCENTAGE OF ALLOWABLE OPENINGS.