Plan Review Details - Permit 00090138
Plan Review Stops For Permit 00090138
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-03-06 Cont ID  
Sent By dpalmer Date 2001-03-06 Time 17:32 Rev Time 0.00
Received By dpalmer Date 2001-03-06 Time 17:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-02-27 Cont ID  
Sent By dpalmer Date 2001-02-27 Time 17:40 Rev Time 0.00
Received By dpalmer Date 2001-02-27 Time 17:40 Sent To  
Notes
2001-02-27 00:00:00************** UNSAT ******************
  
 1)NOTE: PLAN NOT COMPLETE WITH RISER
  
  
 PLEASE SUBMITTHE ABOVE FOR REVIEW

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-09-21 Cont ID  
Sent By dpalmer Date 2000-09-21 Time 23:04 Rev Time 0.00
Received By dpalmer Date 2000-09-21 Time 23:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-09-16 Cont ID  
Sent By jleech Date 2000-09-16 Time 10:15 Rev Time 0.25
Received By jleech Date 2000-09-16 Time 10:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-10-29 Cont ID  
Sent By tlarge Date 2000-10-29 Time 12:31 Rev Time 0.30
Received By tlarge Date 2000-10-29 Time 12:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-10-12 Cont ID  
Sent By tlarge Date 2000-10-12 Time 22:51 Rev Time 0.50
Received By tlarge Date 2000-10-12 Time 22:51 Sent To  
Notes
2001-01-08 00:00:00LAUNDRY TRAYS SHALL BE SHOWN AS STACKED
 AND VENTED.SPC SEC.901.2.
  
 2)THE LOCATION OF THE FIXTURES ON THE
 SANITARY RISERS DO NOT CORRELATE W/THE
 FLOOR PLANS.(SEE LAVS IN M.B.,KIT.SINKS,
 L.T.,B-2,ETC.)COUNTYWIDE AMENDMENTS TO
 SPC SEC.104.2.1.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-09-11 Cont ID  
Sent By tlarge Date 2000-09-11 Time 08:06 Rev Time 1.00
Received By tlarge Date 2000-09-11 Time 08:05 Sent To  
Notes
2001-01-08 00:00:001)THE SANITARY RISERS DO NOT CORRELATE
 W/THE APPROPRIATE FLOOR PLANS.(APPEAR TO
 BE FLIPPED.)COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 2)OPTIONAL LAUNDRY TRAY ON FLOOR PLAN
 NOT SHOWN ON SANITARY RISER.COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.
  
 3)PLANS SHOW 50 GAL.WATER HEATERS AND
 ENERGY CALCS.NOTE 40 GAL.COMPLY W/F.E.C.
 SEC.103.2.
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.
  
 *****NOTE:THESE COMMENTS ALSO APPLY TO
 PERMIT NUMBERS:00090140
 00090143
 00090145
 00090147
 00090148

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-10-30 Cont ID  
Sent By jgomez Date 2000-10-30 Time 17:42 Rev Time 3.00
Received By jgomez Date 2000-10-30 Time 17:03 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE SOIL TEST REPORT AS PER SECT'N
 1804.2.7.2 AND TABLE 1804.2.7.3 OF
 CITY AMENDMENTS TO SBC 1997.
 2-PROVIDE COMPLETE STORM PANELS INFO.
 UNDER A SEPARATE PERMIT.
 3-PROVIDE PRODUCT APPROVAL FOR:
 -INSWING FRENCH DOOR WITH SIDELITES.
 -BBQ UL LISTING AND SPECIFICATIONS.
 -OUTSWING FRENCH DOORS.
 4-USE SITE SPECIFIC PRODUCT APPROVAL
 FORM ATTACHED FOR INSWING ENTRY DOOR.
  
 -THIS FORM TO BE SIGNED, SEALED & DATED
 BY THE MANUFACTURER'S ENGINEER AND BY
 THE ENGINEER OF RECORD.
 -PLEASE AVOID UNNECESSARY RETURNS. MAKE
 SURE FORM IS FILLED COMPLETELY WITH
 ALL THE SPECIFICATIONS AND THE
 ENGINEERS NAMES, LICENSE NUMBERS AND
 ADDRESSES ARE CLEARLY INCLUDED.
 -FILL IN THE JOB SPECIFIC ADDRESS.
 5-PROVIDE CERTIFICAT'N FROM MANUFACTURER
 STATING THAT CONCRETE BLOCK EQUIVALENT
 THICKNESS WILL PROVIDE TWO HOUR FIRE
 RATING ACCORDING TO ASTM C 140.
 SECTION 709.3 SBC 1997.
 6-REVISE DOOR BUCK DETAIL. BUCK SIZE IS
 2X4 AND ANCHOR SPECIFIED IS 1 1/2"
 LONG.
 7-GARAGE DOOR APPROVED DRAWINGS ARE NOT
 LEGIBLE. PLEASE RESUBMIT.
 8-FLOOD ZONE "AO". PROVIDE ELEVATION
 CERTIFICATE.
  
 NOTES:
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-10-10 Cont ID  
Sent By jgomez Date 2000-10-10 Time 17:42 Rev Time 1.00
Received By jgomez Date 2000-10-10 Time 17:42 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-ENERGY CALCULATIONS:
 -REVISE NUMBER OF UNITS. SEE PLANS.
 -REVISE NUMBER OF BEDROOMS. (THREE)
 -REVISE OWNER INFORMATION AND FILL IN
 ALL INFORMATION ON TOP OF FORM.
 -OWNER/AGENT TO DATE FORM.
 2-WALK-IN CLOSETS AT ALL UNITS DON'T
 COMPLY WITH THE FAIR HOUSING ACT.
 SEE PAGE 3.15 FOR MINIMUM WIDTH FOR A
 WALK-IN CLOSET. DELETING THE SHELF AND
 ROD ON EITHER SIDE WILL COMPLY WITH
 THE FAIR HOUSING ACT.
 -SHELF ON ONE SIDE WILL BE ACCEPTABLE
 WHEN THERE IS CLEAR MINIMUM WIDTH OF
 5'-0" WITHOUT INCLUDING THE SHELF.
 3-PROVIDE SOIL TEST REPORT AS PER SECT'N
 1804.2.7.2 AND TABLE 1804.2.7.3 OF
 CITY AMENDMENTS TO SBC 1997.
 4-SPECIFY HARDWARE FOR ENTRY ACCESSIBLE
 DOORS FOR COMPLIANCE WITH THE FAIR
 HOUSING ACT.
 5-REVISE DIMENSIONS ON OPTION #5 PAGE 2
 TO MATCH FLOOR PLAN.
 6-STORM PANELS:
 -PROVIDE COMPLETE INFORMATION, INCLUD'G
 COMPLETE INSTALLATION SCHEDULE AS PER
 CITY SAMPLE ATTACHED AND KEY PLAN.
 ALSO, CLEARLY HIGHLIGHT DRAWINGS
 INDICATING MOUNTING CONDITIONS AND
 ANCHOR TO BE USED ACCORDING TO DESIGN
 PRESSURES, STRUCTURE TO BE ATTACHED
 (THIS IS CONCRETE BLOCK CONSTRUCTION,
 NOT 3000PSI CONCRETE), EDGE DISTANCE,
 PANEL SPAN AND CONNECTION TYPE.
 NOTE: IF COMPLETE INFORMATION IS NOT
 SUBMITTED AT TIME OF RESUBMITTAL, THEN
 A SEPARATE PERMIT WILL BE REQUIRED.
 7-PROVIDE CALCULATIONS FOR CROSS VENTI-
 LATION AT EACH UNIT ATTIC SPACE.
 SECTION 2309.7 SBC 1997.
 8-PROVIDE PRODUCT APPROVAL FOR:
 -INSWING ENTRY DOOR.
 -INSWING FRENCH DOOR WITH SIDELITES.
 -BBQ UL LISTING.
 -CERTIFICATION FROM MANUFACTURER'S
 ENGINEER STATING THAT CONCRETE BLOCK
 EQUIVALENT THICKNESS WILL PROVIDE TWO
 HOUR FIRE RATING ACCORDING TO ASTM
 C140. SECTION 709.3 SBC 1997.
 -OUTSWING FRENCH DOORS.
 9-PROVIDE STRUCTURAL BUCK DETAIL FOR
 SLIDING GLASS DOORS. SEC 104.2 CITY
 AMENDMENTS.
 10-PROVIDE COMPLETE DETAIL/SPECIFICATION
 FOR CEILING CONSTRUCTION AT FRONT AND
 BACK PORCH. SEC 2504 SBC 1997.
 NOTE: INCLUDE FASTENER TYPE & SPACING.
 11-PROVIDE PRODUCT APPROVAL FOR GARAGE
 DOORS.
 12-CONTRACTOR TO UPDATE INSURANCE AND
 WORKERS COMPENSATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-09-09 Cont ID  
Sent By gjoyce Date 2000-09-09 Time 08:43 Rev Time 0.15
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***