Plan Review Details - Permit 00090113
Plan Review Stops For Permit 00090113
Review Stop E ELECTRICAL
Rev No 6 Status P Date 2001-08-03 Cont ID  
Sent By dpalmer Date 2001-08-03 Time 16:39 Rev Time 0.00
Received By dpalmer Date 2001-08-03 Time 16:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-04-24 Cont ID  
Sent By dpalmer Date 2001-04-24 Time 20:05 Rev Time 0.00
Received By dpalmer Date 2001-04-24 Time 20:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-12-06 Cont ID  
Sent By dpalmer Date 2000-12-06 Time 16:44 Rev Time 0.00
Received By dpalmer Date 2000-12-06 Time 16:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2000-11-27 Cont ID  
Sent By dpalmer Date 2000-11-27 Time 12:28 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00***************** UNSAT ****************
  
  
 1)NOTE: PLEASE SHOW AIC RATINGS FOR ALL
 EQUIPMENT AS ASKED FOR. AIC RATINGS MUST
 BE ON PLANS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-11-06 Cont ID  
Sent By dpalmer Date 2000-11-06 Time 19:52 Rev Time 0.00
Received By dpalmer Date 2000-11-06 Time 19:52 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ***************
  
 1)NOTE: AS PER 215-5 AND 110-9 AND AS
 ASKED FOR ON FIRST REVIEW, AIC RATINGS
 FOR ALL EQUIPMENT IS REQ`D ON PLANS FOR
 MAIN DISCONNECTS AND PANELS. ALL MUST BE
 RATED PER 110-9. THE AVAILABLE FAULT
 CURRENT CAN BE GOTTEN FROM FPL AND THE
 EQUIPMENT CAN BE PER THEIR A.F.C OR A
 FAULT CURRENT CALCUALTION CAN BE DONE TO
 SEE IF EQUIPMENT WITH LOWER AIC RATINGS
 CAN BE INSTALLED. IF THERE ARE ANY
 QUESTIONS ON THE ABOVE, PLEASE DO NOT
 HESITATE IN CONTACTING ME.
  
 2)NOTE: ALSO PLEASE CLARIFY THE LOADS
 SHOWN FOR A/C`S?? PANELS LIST LOADS AT
 5KW OR 10KW AND THEN IN THE FAR RIGHT
 COLULMN LOADS ARE LISTED WITH AN ADDIT-
 -IONAL 700W ?? PLEASE EXPLAIN.
  
  
 PLEASE SUBMIT THE ABOVE. THE AIC RATINGS
 FOR EQUIPMENT IS REQ`D AND IF THERE
 ARE ANY QUESTIONS PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-09-21 Cont ID  
Sent By dpalmer Date 2000-09-21 Time 23:10 Rev Time 0.00
Received By dpalmer Date 2000-09-21 Time 23:10 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT *****************
  
 PLEASE SEE E-1 FOR THE FOLLOWING.
  
 1)NOTE: PLEASE INCLUDE BLDG STEEL AS
 PART OF THE GROUNDING ELECTRODE SYSTEM
 PER 250-50
  
 2)NOTE: PLEASE SUBMIT AIC RATING FOR
 ALL EQUIPMENT BEING INSTALLED. MAINS/
 PANELS/BREAKERS ALL MUST BE RATED FOR
 AVAILBLE FAULT CURRENT PER 110-9.215-5
  
 3)NOTE: PLEASE SEE LOADS SHOWN ON LOAD
 CALCULATIONS,, THE LOADS SHOWN DO NOT
 ADD UP TO WHAT IS SHOWN FOR TOTAL LOAD.
 ADDING THE KVA SHOWN PUTS SERVICE OVER
 300AMPS.PLEASE CLARIFY AND INCREASE
 SERVICE IF NEEDED. PER 220
  
 4)NOTE: PLEASE SHOW SIZE OF METERCAN.
 215-5
  
 5)NOTE: PLEASE SHOW ALL CONDUCTOR SIZES
 ON RISER DIAGRAM.(GUTTER/METER) ETC.
  
 6)NOTE: PLEASE SEE 250-122 FOR REQ`D
 EQUIPMENT GROUNDING CONDUCTOR AFTER
 FIRST MEANS OF DISCONNECT.
  
 7)NOTE: PLEASE SEE CONDUITS SHOWN AS 3/4
 INCH CONDUIT W/ 3# 3`S??? CONDUIT FILL
 PER APPENDIX "C" OF THE NEC.
 PLEASE CORRECT.
  
 8)NOTE: PLEASE CORRELATE LOADS FOR A/C
 UNITS ON PANEL SCHEDULES.ONE SHOWS LOAD
 AT 5KW AND THEN 5.7KW?? AND SO ON FOR
 A/C LOADS??
 PLEASE CLARIFY.
  
 PLEASE SEE E-2 FOR THE FOLLOWING.
  
 1)NOTE:SMOKE DETECTORS ARE REQ`D INSIDE
 AND OUTSIDE ALL SLEEPING ROOMS AND
 ADAPTABLE SLLEPING ROOMS WHICH ARE ROOMS
 W/ CLOSETS AND OR BATHROOMS. ALSO
 SMOKE DETECTOR ARE REQ`D ON EACH LEVEL
 OF A MULTI-LEVEL RESIDENCE AND IN COMMON
 AREA.PLEASE SEE NFPA-72 2-2.1.1.1
 ALSO SBCCI 97 FOR NFPA 101
  
 PLEASE SEE E-3 FOR THE FOLLOWING.
  
 1)NOTE: PLEASE NOTE SMOKE DETECTOR REQ`
 -MENTS IN THIS AREA ALSO.
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW, IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-08-04 Cont ID  
Sent By hmoser Date 2001-08-04 Time 10:45 Rev Time 0.50
Received By hmoser Date 2001-08-04 Time 10:44 Sent To  
Notes
2001-08-04 00:00:00REVISON OK CALLED BRYON FROM CHEROKEE
 CONST.PLANS IN BOX C H.MOSER 8/4/01

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-04-23 Cont ID  
Sent By pkrauss Date 2001-04-23 Time 08:48 Rev Time 0.30
Received By pkrauss Date 2001-04-23 Time 08:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-09-16 Cont ID  
Sent By jleech Date 2000-09-16 Time 13:46 Rev Time 0.50
Received By jleech Date 2000-09-16 Time 13:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2001-08-01 Cont ID  
Sent By kstevens Date 2001-08-01 Time 16:57 Rev Time 0.50
Received By kstevens Date 2001-08-01 Time 16:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-11-01 Cont ID  
Sent By tlarge Date 2000-11-01 Time 10:59 Rev Time 0.65
Received By tlarge Date 2000-11-01 Time 10:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-09-27 Cont ID  
Sent By tlarge Date 2000-09-27 Time 17:16 Rev Time 0.25
Received By tlarge Date 2000-09-27 Time 17:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-09-13 Cont ID  
Sent By tlarge Date 2000-09-13 Time 19:31 Rev Time 0.33
Received By tlarge Date 2000-09-13 Time 19:31 Sent To  
Notes
2001-01-08 00:00:001)FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE VENTED PER SPC SEC.913.2.
  
 2)BASE OF VENTS SHALL BE WASHED PER SPC
 906.2.1.
  
 3)BAR SINK NOT VENTED.SPC 901.2.
  
 4)SUBMIT SANITARY RISER THAT COMPLIES W/
 THE STANDARD PLUMBING CODE.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-09-12 Cont ID  
Sent By tlarge Date 2000-09-12 Time 06:52 Rev Time 0.65
Received By tlarge Date 2000-09-12 Time 06:36 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY RISER FOR REVIEW THAT
 REFLECTS ENTIRE SCOPE OF PLUMBING SYSTEM
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2001-03-21 Cont ID  
Sent By jgomez Date 2001-03-21 Time 11:55 Rev Time 1.00
Received By jgomez Date 2001-03-21 Time 11:55 Sent To  
Notes
2001-03-21 00:00:00STRUCTURAL REVISIONS.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-12-06 Cont ID  
Sent By jgomez Date 2000-12-06 Time 17:48 Rev Time 4.00
Received By jgomez Date 2000-12-05 Time 19:23 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE PRODUCT APPROVALS FOR:
 A)FRENCH DOORS WITH SIDELITES AND ROUND
 TRANSOM ABOVE COMPLETE ASSEMBLY AS
 SHOWN ON STUDY ROOM.
 B)FRENCH DOORS WITH FIXED GLASS COMPLETE
 ASSEMBLY AS SHOWN ON MASTER BEDROOM,
 LIVING ROOM AND FAMILY ROOM.
 C)ROUND AND ARCHED WINDOWS.
 D)FIXED RECTANGULAR WINDOWS
 E)FRENCH DOORS WITH ROUND TRANSOM ABOVE
 AS SHOWN ON ENTRY DOORS.
 F)SEE COMMENTS ON PRODUCT APPROVALS
 SUBMITTED.
  
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
  
  
  
 NOTES:
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.
 -NEED TO APPLY FOR SEPARATE PERMITS FOR
 ELECTRICAL, MECHANICAL, PLUMBING AND
 ROOFING WORK (ORIGINAL APPLICATION WAS
 NOT SIGNED BY THEM)

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-11-21 Cont ID  
Sent By jgomez Date 2000-11-21 Time 15:06 Rev Time 5.00
Received By jgomez Date 2000-11-21 Time 15:06 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-STRUCTURAL DRAWINGS NEED TO BE SIGNED,
 SEALED AND DATED BY THE STRUCTURAL
 ENGINEER OF RECORD.
 -STRUCTURAL DRAWINGS TO BE COORDINATED
 WITH THE ARCHITECTURAL DRAWINGS.
 KEYED DETAILS DON'T MATCH THE ACTUAL
 CONDITIONS. PLEASE REVIEW ALL ARCH'AL
 AND STRUCTURAL DRAWINGS AND PROVIDE
 A CLEAR COMPLETE SET OF CONSTRUCTION
 DOCUMENTS.
 2-REVISE THE DESIGN CERTIFICATION FOR
 WIND LOAD COMPLIANCE FORM. MEAN ROOF
 HEIGHT IS +/- 31'-6" NOT 24'. SEE
 COMMENTS ON THE FORM.
 -ALSO, CLARIFY WHAT IS THE EB6612
 NUMBER FOR. THIS DOESN'T MATCH THE
 ENGINEER LICENSE NUMBER ON THE SEAL.
 3-THERE IS NO INFORMATION GIVEN FOR THE
 SPIRAL STAIRS. SPECIFICATIONS,FOOTING,
 DIMENSIONS, DETAILS, ETC.
 4-PROVIDE CONSTRUCTION DETAILS FOR BAY
 WINDOW AT BREAKFAST AREA. ATTACHMENT
 OF WINDOWS TO THE STEEL COLUMN.
 5-PROVIDE ENGINEERS CERTIFICATION FOR
 SOIL DEMUCKING AND FILLING AS PER
 SOIL TEST REPORT RECOMMENDATIONS.
 6-PROVIDE CALCULATIONS FOR VENTILATION
 OF ATTIC. SEC 2309.7 SBC 1997. VERIFY
 SIZE AND SPACING OF VENTS SPECIFIED.
 7-OWNER/AGENT TO SIGN AND DATE THE
 ENERGY CALCULATIONS.
 8-PROVIDE ATTIC ACCESS AT MASTER BEDROOM
 ROOF WING. SEC 2309.6 SBC 1997.
 9-GARAGE DOORS PRODUCT APPROVAL DON'T
 MEET THE DESIGN PRESSURES CALCULATED
 BY THE STRUCTURAL ENGINEER.
 10-SPECIFY AND IDENTIFY THE SHEARWALLS.
 11-PROVIDE PRODUCT APPROVAL FOR:
 -FRENCH DOORS WITH FIXED GLASS ASSEMBLY
 AS SHOWN ON COVERED PATIO AREA.
 -FLAT ROOF SYSTEM (EXPIRED).
 -SINGLE HUNG WINDOWS AND ROUND WINDOWS.
 -MULLIONS FOR MISSILE IMPACT ASSEMBLIES
 -FIREPLACE UL LISTING & SPECIFICATIONS.
 12-PROVIDE COMPLETE INFORMATION FOR
 STORM PANELS, INCLUDING COMPLETE
 INSTALLATION SCHEDULE (SEE ATTACHED
 SAMPLE) AND KEY PLAN AND CIRCLE THE
 MOUNTING CONDITIONS AND ANCHORS USED.
 NOTE:THIS INFORMATION MAY BE SUBMITTED
 LATER UNDER A SEPARATE PERMIT.
 13-NORANDEX WINDOWS AND DOORS SITE
 SPECIFIC PRODUCT APPROVAL NEED TO BE
 SIGNED,SEALED,DATED BY THE STRUCTURAL
 ENGINEER OF RECORD AS WELL.
 -SPECIFY WINDOWS/DOORS AND COMPONENTS
 TO BE USED IN THIS SITE SPECIFIC
 APPLICATION.
 -ENGINEER TO INCLUDE LEGIBLE NAME,
 ADDRESS, LICENSE NUMBER AS REQUESTED
 BY CHAPTER 471 OF FLORIDA STATUTES.
 14-SEE COMMENTS ON PRODUCT APPROVALS
 SUBMITTED AND ON REVIEWED SET OF
 DRAWINGS.
  
  
  
 NOTES:
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 X 8232.
 -PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-09-30 Cont ID  
Sent By jgomez Date 2000-09-30 Time 17:19 Rev Time 6.00
Received By jgomez Date 2000-09-30 Time 17:19 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC 2405.2 SBC 1997.
 3-PROVIDE ATTIC ACCESS AT MASTER BEDROOM
 ROOF WING. SEC 2309.6 SBC 1997.
 4-PROVIDE SURVEY WITH BUILDING LAYOUT.
 SURVEY SUBMITTED IS FOR MORTGAGE USE,
 NOT FOR BUILDING PERMIT.
 5-PROVIDE SOIL TEST REPORT WITH THE MIN.
 INFORMATION REQUIRED ON SEC. 1804.2.7
 AND TABLE 1804.2.7.3 CITY AMENDMENTS.
 6-SPECIFY THE DESIGN PRESSURES AT ALL
 EXTERIOR OPENINGS.
 NOTE: ALL STRUCTURAL DESIGN SHALL
 CONFORM TO SSTD-10-97 WHICH IS THE
 PRESCRIPTIVE STANDARD CODE ADOPTED BY
 THE CITY OF WEST PALM BEACH WHEN THE
 DESIGN IS NOT PERFORMED BY A LICENSED
 ARCHITECT OR ENGINEER. SEE SECTION
 104.2.3 OF CITY AMENDMENTS TO SBC 1997
 7-PROVIDE COMPLETE CONSTRUCTION DETAIL/
 SECTION TRHU BALCONIES. SEC. 104.2.2
 CITY AMENDMENTS TO SBC 1997.
 8-PRODUCT APPROVAL SUBMITTED FOR GARAGE
 DOORS REQUIRE SUPPORTING BUCK DETAIL
 TO BE DESIGNED BY AND ARCHITECT OR
 ENGINEER. SEE SEC 9.3 OF THE PRODUCT
 APPROVAL REPORT AND GENERAL NOTE ON
 APPROVED DRAWINGS.
 9-MISSING DRAWINGS A-10 & S-3. SEE INDEX
 10-STRUCTURAL PLANS:
 -CLEARLY KEY ALL DETAILS THAT APPLY TO
 THIS PROJECT.
 11-PROVIDE COMPLETE LOAD CALCULATIONS
 (REACTIONS AND UPLIFT) AND PROVIDE A
 COMPLETE ANCHOR SCHEDULE. USE SSTD 10-
 97. SEC. 104.2.3 CITY AMENDMENTS.
 12-PROVIDE A COMPLETE CHIMNEY DETAIL/
 SECTION SHOWING ALL FASTENERS AND
 STRUCTURAL COMPONENTS. SECTION 104.2.2
 CITY AMENDMENTS.
 13-FOUNDATION, SECOND FLOOR AND ROOF
 PLANS NEED MORE INFORMATION:
 -PROVIDE COMPLETE FRAMING DETAILS.
 -SPECIFY TRUSS GIRDER SUPPORTS AND
 CONNECTIONS.
 USE SSTD 10-97 AS REFERENCE.
 14-PROVIDE COMPLETE 2 STORY WALL SECTION
 SPECIFYING ALL CONNECTORS.
 USE SSTD 10-97.
 15-SPECIFY AND IDENTIFY THE SHEARWALLS.
 USE SSTD 10-97.
 16-PROVIDE PRODUCT APPROVALS FOR:
 -FRENCH DOORS WITH SIDELITES AND FRENCH
 DOORS WITHOUT SIDELITES.
 -FRENCH DOORS WITH FIXED GLASS ASSEMBLY
 AS SHOWN ON COVERED PATIO AREA.
 -ROOF TILE AND FLAT ROOF SYSTEM.
 -SINGLE HUNG WINDOWS.
 -WINDOW AND DOOR MULLIONS.
 -BUTT GLAZING ASSEMBLY BY BREAKFAST.
 -FIREPLACE LISTING MEETING THE
 REQUIREMENTS OF UL 127.
 17-ADDITIONAL PERMIT FEES ARE OWED FOR
 LOW PROJECT VALUATION AND RADON FEES:
 $681.96.
 18-SEE ADDITIONAL COMMENTS ON PLANS AND
 COMMENTS BY THE OTHER TRADES.
  
  
  
  
  
 NOTES:
 -PLEASE RETURN REVIEWED SET AFTER THE
 CORRECTIONS ARE MADE TO THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.
 -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL
 FREE TO CONTACT JULIO GOMEZ AT
 659-8096 EXT. 8232.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-09-11 Cont ID  
Sent By gjoyce Date 2000-09-11 Time 08:13 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***