Plan Review Details - Permit 00090070
Plan Review Stops For Permit 00090070
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-03-21 Cont ID  
Sent By dpalmer Date 2001-03-21 Time 08:58 Rev Time 0.00
Received By dpalmer Date 2001-03-21 Time 08:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-09-21 Cont ID  
Sent By dpalmer Date 2000-09-21 Time 23:01 Rev Time 0.00
Received By dpalmer Date 2000-09-21 Time 23:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-09-16 Cont ID  
Sent By jleech Date 2000-09-16 Time 09:17 Rev Time 0.33
Received By jleech Date 2000-09-16 Time 09:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-05-11 Cont ID  
Sent By kstevens Date 2001-05-11 Time 16:23 Rev Time 0.25
Received By kstevens Date 2001-05-11 Time 16:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-10-21 Cont ID  
Sent By tlarge Date 2000-10-21 Time 07:18 Rev Time 0.50
Received By tlarge Date 2000-10-21 Time 06:00 Sent To  
Notes
2001-01-08 00:00:00*****************PROVISO****************
 1)COMPLY W/SPC SECS.714.4,409.12.3.
  
 LOCATION OF FIXTURES ON SANITARY RISER
 SHALL CORRELATE W/FLOOR PLAN.COUNTYWIDE
 AMENDMENTS TO SPC SEC.104.2.1.SUBMIT
 REVISED RISERS PRIOR TO INSPECTION.
  
 CALL IF YOU HAVE QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-10-03 Cont ID  
Sent By rmcdouga Date 2000-10-03 Time 10:12 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED PER PAUL SCHMITZ 9-10-00 RLM
 ISOMETRIC TO MATCH FLOOR PLAN.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-10-31 Cont ID  
Sent By rmcdouga Date 2000-10-31 Time 14:22 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-10-02 Cont ID  
Sent By rmcdouga Date 2000-10-02 Time 17:37 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00****************DENIED******************
  
 1)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY,PLANS STAMPED BY THEM AND RECEIPT
 SUBMITTED TO CITY OF WPB CONSTRUCTION
 SERVICES DEPT. BEFORE A PERMIT TO
 CONSTRUCT WILL BE ISSUED.
  
 2)STRUCTURE IS LOCATED IN AN "AO" FLOOD
 ZONE. PLEASE PROVIDE ELEVATION
 CERTIFICATE WHEN PROJECT IS COMPLETE PER
 FEMA REQUIREMENTS.
  
 3)PROVIDE SOIL COMPACTION TEST AT FIRST
 INSPECTION.
  
 4)PROVIDE ENGINEERING OR LETTER FROM
 MANUFACTURER CERTIFYING THE APPLICATION
 OF JOIST HANGER EHUH 210 ON MASONRY AND
 THE SIZE,TYPE AND NUMBER OF FASTENERS
 REQUIRED.
  
 5)PLEASE PROVIDE ADDITIONAL DATA ON 2 HR
 FIRE RATED BLOCK THAT WILL BE USED ON
 THIS PROJECT.
  
 6)DETAIL #6 ON SHEET 8 IS CROSSED OUT,
 HOWEVER IT IS REFERENCED ON SHEET 7.
 PLEASE CLARIFY AND SPECIFY CONNECTOR TO
 BE USED FOR GIRDER TRUSSES ON PORCHES.
  
 7)DETAIL 2A ON SHEET 8 IS CROSSED OUT,
 YET IT IS REFERENCED ON SHEET 7.
  
 8)PLEASE USE CITY OF WPB PRODUCT APPROV-
 AL SUBMITTAL FORM WHEN SUBMITTING SITE
 SPECIFIC ENGINEERING. PROVIDE SPECIFIC
 JOB/SITE LOCATION (ADDRESS,LOT#)ON FORM.
 ALSO ENGINEER/ARCHITECT IS REQUIRED TO
 PROVIDE LEDGIBLE NAME,ADDRESS AND
 REGISTRATION NUMBER ON FORM. PER FL STAT
 UTES.
  
 8)THE WIND LOADS GIVEN ON SHEET 5 OF
 PLANS FOR THE SLIDING GLASS DOORS EXCEED
 THE DESIGN LOAD CAPACITIES OF THE DOORS
 ON THE PRODUCT SUBMITTAL FORM. PLEASE
 RECHECK THE CALCULATIONS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-09-09 Cont ID  
Sent By gjoyce Date 2000-09-09 Time 08:49 Rev Time 0.10
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***