| Plan Review Stops For Permit 00081726 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2000-12-05 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-12-05 |
Time |
12:39 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-12-05 |
Time |
12:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-10-11 |
Time |
13:31 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-10-11 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.SUBMIT PRODUCT APPROVALS FOR WINDOW & | | | DOOR GLAZING FOR STOREFRONT/ METRO DADE | | | COUNTRY OR SBCCI SSTD12-97 | | | 2. SUBMIT PLANS AND APPLICATION FOR | | | PERMIT FOR FIRE SPRINKLER | | | | | | PROVISO | | | 1.ALL WOOD TO BE FRT PER CHAPTER 6 SBC | | | 2.SIGNS TO BE UNDER SEPARATE PERMIT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-09-13 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-09-13 |
Time |
14:53 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-09-13 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.SHEET A0.1 | | | CHANGE CODE REFRENCE TO SBC 1997 | | | EDITION. | | | BUILDING CONST.IS TYPE 2 NOT TYPE 4 | | | 2.SHEET A5.2 SECTION 13 NOTE AT TOP | | | SHOWS 5/8 INCH PLYWOOD & NOTE AT | | | BOTTOM SHOWS 1/2 PLYWOOD PLEASE | | | CLARIFY? | | | 3.SUBMIT WALL SECTION SHOWING TENANT | | | DENIZING WALLS FIRE RATING AND UL # | | | | | | 4.SUBMIT FIRE SPRINKLER PLANS AND | | | APPLICATION FROM SPRINKLER CONTRACTOR. | | | 5.SUBMIT PRODUCT APPROVAL FOR WINDOW & | | | DOOR GLAZING FOR STOREFRONT/ MTERO | | | DADE COUNTY OR SBCCI SSTD12-97. | | | | | | PROVISO | | | 1) ALL WOOD TO BE FRT PER SP.3 SECTION | | | 06100. | | | 2) SIGNS TO BE UNDER SEPERATE PERMIT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-21 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-21 |
Time |
18:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-11 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-11 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-09-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-12 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-12 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE PROVIDE INFORMATION FOR | | | ENGINEER OF RECORD PER FL ADMINISTRATIVE | | | CODE.61G15-23.002 | | | | | | 2)NOTE: PLEASE PROVIDE CLARIFICATION | | | ON WIRE SIZE FEEDING PANEL "DP". | | | PANEL IS SHOWN TO BE 225A MAX.? | | | | | | 3)NOTE: PLEASE SHOW ALL RECEPTS UNDER | | | 210-8 AS BEING GFI/GFI PROTECTED. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-11 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-11 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO HYDRAULIC CALCULATIONS PROVIDED | | | WITH FIRE SPRINKLER DRAWINGS. | | | 2) PROVIDE FIRE ALARM SYSTEM SHOP | | | DRAWINGS FOR FIRE ALARM EQUIPMENT SHOWN | | | ON DRAWINGS. | | | APPROVED PROVISO: |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-09-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-09-12 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-09-12 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO HYDRAULIC CALCULATIONS PROVIDED | | | FOR FIRE SPRINKLER PLAN. | | | 2) NO FIRE ALARM EQUIPMENT SHOWN ON | | | PLANS. HOW IS BASE BUILDING FIRE ALARM | | | SYSTEM HEARD WITHIN TENANT SPACE. | | | 3) PROVIDE EMERGENCY LIGHTING IN | | | STOCKROOM. | | | 4) EXITING PERMITTED IN STOCKROOM IF THE | | | FOLLOWING CONDITIONS EXIT, DOOR LEADING | | | TO STOCKROOM CANNOT BE LOCKED, AN AISLE | | | OF AT LEAST 44" WIDE IS TO BE PROVIDED | | | AND MAINTAINED, AND NOT MORE THAN 50 | | | PERCENT OF THE EXIT ACCESS IS TO BE | | | PROVIDED THROUGH STOCKROOM. | | | 5) FIRE EXTINGUISHERS ARE TO BE PROVIDED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2001-03-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-28 |
Time |
13:25 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-03-28 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2001-03-28 00:00:00 | ONLY PROVIDED 1 SET OF PLANS | | | AS BUILTS - KEEP PLANS SUBMITTED, RED | | | LINED IN FIELD, OKAY PER LOU HATTON. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-19 |
Time |
08:56 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-12-19 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-12-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-04 |
Time |
14:33 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-12-04 |
Time |
14:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2000-10-17 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-10-17 |
Time |
17:33 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-10-17 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************DENIED******************** | | | 1. THE USE OF CO2 SENSORS TO REDUCE THE | | | AMOUNT OF OUTSIDE AIR REQUIRED BY ASHRAE | | | 62-89 IS NOT SPECIFIED AS AN ALTERNATIVE | | | METHOD. ACCEPTABLE REDUCTION METHODS ARE | | | GIVEN IN 6.1.3.4 INTERMITTENT OR | | | VARIABLE OCCUPANCY. "PEAK OCCUPANCIES OF | | | LESS THAN THREE HOURS DURATION" AND WHEN | | | "PROVIDED THE AVERAGE OCCUPANCY USED IS | | | NOT LESS THAN ONE-HALF THE MAXIMUM. | | | THE USE OF CO2 SENSORS TO REDUCE REQUIRE | | | AMOUNTS OF OUTSIDE AIR DOES NOT TAKE INT | | | CONSIDERATION THE EFFECTS OF POSSIBLE | | | ELEVATION OF OTHER CONTAMINANTS. | | | 2. DRAWING M 2.1 SHOWS AUX. PAN DRAIN | | | CONNECTED TO PRIMARY CONDENSATE DRAIN | | | LINE. DETAIL IN CIRCLE DOES NOT SHOW | | | THIS. NOTE THAT AUX DRAIN LINE SHALL NOT | | | BE CONNECTED TO PRIMARY DRAIN LINE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-09-13 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-13 |
Time |
12:34 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-09-13 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | 1.PROVIDE INFORMATION ON O/A DAMPER | | | CAPACITIES (MAX AND MIN) | | | DO NOT REDUCE OUTSIDE AIR BELOW | | | VALUES SHOWN ON M2.0 ( 1940 CFM) BY CO2 | | | SENSOR. 1940 CFM IS MINIMUM REQUIRED | | | VOLUME PER ASHRAE 62-89 TABLE 2. | | | 2 PROVIDE AIR BALANCE SCHEDULE SHOWING | | | COMPLIANCE WITH 1997 SMC 501.2 | | | 3.CONDENSATE DRAIN LINE AND EMERGENCY | | | OVERFLOW DRAIN LINE SHALL NOT CONNECT | | | TOGETHER. OVERFLOW DRAIN LINE SHALL | | | TERMINATE IN A CONSPICOUS LOCATION. 1997 | | | SMC 304.8.6.1 | | | 4. NOTE: RETURN AIR PLENUM AREA ABOVE | | | CEILING TO BE CONSTRUCTED ENTIRELY OF | | | NONCOMBUSTIBLE MATERIALS. PER 1997 SMC | | | 609.1.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-10-07 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-07 |
Time |
09:30 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
2000-10-07 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-09-12 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-12 |
Time |
18:20 |
Rev Time |
1.00 |
| Received By |
tlarge |
Date |
2000-09-12 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)TITLE SHEET-CODE INFORMATION-NOTE | | | STANDARD PLUMBING CODE W/1999 COUNTYWIDE | | | AMENDMENTS. | | | | | | 2)SUBMIT SQUARE FOOTAGE OF HABITABLE | | | FLOOR SPACE TO SHOW COMPLIANCE W/SPC | | | TABLE 407.SEE SPC SEC.407.1.3. FOR | | | ALLOWED DEUCTIBLE AREAS.ADDITIONAL | | | PLUMBING FIXTURES MAY BE REQD. | | | | | | 3)DOOR CANNOT SWING INTO CLEAR FLOOR | | | SPACE FOR LAV.IN MEN'S TOILET ROOM PER | | | FACBC SEC.4.22.2. | | | | | | 4)MAX.HT.OF LAVATORY TO RIM SHALL BE 34" | | | PER FACBC SEC.4.19.2. | | | | | | 5)FLOOR DRAINS IN TOILET ROOM SHALL BE A | | | MIN.OF 3" PER SPC SEC.409.4.1.1. | | | | | | 6)TERMINATION PT.OF T & P LINE SHALL | | | COMPLY W/COUNTYWIDE AMENDMENTS TO SPC | | | SEC.507.8.4.THE LINE SHALL NOT DISCHARGE | | | TO CD. | | | | | | 7)WATER CLOSETS AND FLOOR DRAINS ARE NOT | | | PROPERLY VENTED.COMPLY W/SPC SEC. | | | 906.2.1. | | | | | | 8)CLEANOUTS SHALL BE INSTALLED PER SPC | | | SEC.710.2.1. | | | | | | 9)SHT.M3.0 REFERS TO GAS SYSTEM.IF NOT | | | APPLICABLE REMOVE FROM PLANS. | | | | | | 10)EACH SHEET WHICH MUST BE SEALED BY | | | THE PROFESSIONAL ENGINEER SHALL LEGIBLY | | | INDICATE THEIR NAME,ADDRESS AND NUMBER | | | ON EACH SHEET PER FLA.ADMIN.CODE | | | 61G15-23.002. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|