| Plan Review Stops For Permit 00081675 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2001-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-16 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-16 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2001-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-14 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-14 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2001-08-14 00:00:00 | PROVISO FROM PREVIOUS REVIEW STILL | | | STANDS. 11/27/00 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2000-11-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-27 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-27 |
Time |
17:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************* REVISION REQ'STED ******** | | | | | | 1)NOTE: PLEASE SHOW BLDG. STEEL AS PART | | | OF THE GROUNDING ELECTRODE SYSTEM PER | | | 250-50 ON RISER DIAGRAM. | | | | | | 2)NOTE: PLEASE SHOW AIC RATINGS OF MAINS | | | AND PANEL. PER 110-9 AND 215-5 | | | | | | PLEASE SUBMIT AND SHOW ALL THE ABOVE | | | INFORMATION ON PLAN BEFORE ROUGH ELECTR- | | | -ICAL INSPECTION IS CALLED IN. IF THERE | | | ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-16 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-16 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM PRIOR | | | REVIEWS. NOT ALL NOTES WERE ADDRESSED??? | | | | | | 2)NOTE: PLEASE SEE RISER, PANEL SHOWS | | | IT AS MCB? AND PANEL SCHEDULE SHOWS MLO? | | | PLEASE CORRELATE. | | | | | | 3)NOTE: PLEASE SEE THAT NO AIC RATINGS | | | FOR MAIN DISCONNECT OR PANEL WERE SHOWN? | | | MAINS AND PANELS MUST BE RATED FOR THE | | | AVAILABLE FAULT CURRENT. PER 110-9. | | | | | | 4)NOTE: AS ON PRIOR REVIEW PLEASE SHOW | | | NEW BLDG STEEL AS PART OF THE GROUNDING | | | ELECTRODE SYSTEM. PER 250-50 FOR | | | NEW BLDG FOOTERS.!! | | | | | | 5)NOTE: PLEASE SEE NOTES FROM BLDG AND | | | MY REVIEW. SEE F.A.C 61G16 AND 481.221 | | | PLANS ARE SIGNED,SEALED AND DATED. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-10-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-24 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-24 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE 680-6-A-2 FOR NOTE | | | SHOWN FOR POOL AREA. PLEASE ADJUST PLAN | | | NOTE. | | | | | | 2)NOTE: NOW THAT YOU HAVE SUBMITTED A | | | RISER DIAGRAM SHOWING ALL NEW SERVICE | | | BEING INSTALLED, PLEASE SUBMIT AIC | | | RATINGS FOR ALL EQUIPMENT BEING INSTALL- | | | -ED. MIAN DISC/ AND PANEL MUST BE RATED | | | FOR THE AVAIABLE FAULT CURRENT PER 110-9 | | | AND 215-5. | | | | | | 3)NOTE: PLEASE SEE ART 384-7 AND 110-26 | | | OF THE NEC. NEW PANEL SHOWN IN BATHROOM | | | CLOSET MAY NOT BE INSTALLED IN THAT | | | LOCATION. PLEASE ADJUST LOCATION AND | | | MAKE CHANGES TO PLAN. | | | | | | 4)NOTE: PER 250-50 NEW BLDG STEEL MUST | | | BE BONDED TO GROUNDING ELECTRODE CONDUC- | | | -TOR.PLEASE SHOW ON RISER DIAGRAM 215-5 | | | | | | | | | 5)NOTE: PLEASE SEE THE REQ`MENTS PER FL | | | ADMINISTATIVE CODE FOR PLANS TO CONTAIN | | | INFORMATION ON ARCH OF RECORD. PLEASE | | | CLARIFY FRANCIS DIGIOVANI? IS THIS THE | | | FIRM UNDER WHICH PATRICK SEAGRAVES WORKS | | | ?? PLEASEDATE THE SIGNED AND SEALED | | | PLAN. ALL PER 61G16 AND 471.221. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-09-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-14 |
Time |
20:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-14 |
Time |
20:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT CLARIFICATION ON | | | SERVICE CONDUCTOR SIZE. YOU SHOW #1. | | | PLEASE SEE 310-15 AND 310-16 | | | | | | 2)NOTE: MISSING A/C DISC`S PER 440-11 | | | | | | 3)NOTE:PLEASE LIST REQ`D BATH(S) CIRCUIT | | | (S) PER 210-11-C-3 ON PANEL SCHEDULE.. | | | | | | 4)NOTE: PLEASE SEE LOAD CALCUALTIONS. | | | CALCS DO NOT CORRELATE WITH MECHANICAL | | | PLANS OR ELECTRICAL A/C PLAN LAYOUT. | | | 215-5. | | | | | | 5)NOTE: PLEASE SEE SQ FT BEING ADDED ON | | | BLDG PLANS. THIS ALSO DOES NOT CORRELATE | | | WITH LOAD CALCULATIONS FOR SQ FT/GEN LT. | | | PER 220 | | | | | | 6)NOTE: PLEASE SEE SMALL APPLIANCE | | | CALCSSHOWN. YOU SHOW 4.5 KW AND ONLY | | | TWO CIRCUITS. PLEASE CLARIFY. | | | | | | 7)NOTE: PLEASE SEE RISER DIAGRAM AND | | | CORRELATE WITH ELECTRICAL PLAN. WHERE | | | IS THE SECOND PANEL GOING? PLEASE | | | SUBMIT CLARIFICATION ON SERVICE. | | | NOTE ON ELECTRICAL PLAN SAYS CIRCUITS | | | ARE BEING FED TO EXISTING 200 AMP | | | FUSE PANEL.? RISER DIAGRAM DOES NOT | | | SHOW THIS. | | | | | | 8)NOTE: MISSING WP GFI REC FOR A/C CU`S. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-09-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-09-16 |
Time |
07:43 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-09-16 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-09-13 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-13 |
Time |
20:03 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-09-13 |
Time |
19:56 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO****************** | | | SUBMIT REVISED SANITARY RISER PRIOR TO | | | PLBG.INSPECTION.COUNTYWIDE AMENDMENTS TO | | | SPC SEC.104.2.1. | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2000-11-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-11-17 |
Time |
15:53 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO | | | | | | 1)PROVIDE KEY PLAN AND INSTALLATION | | | SCHEDULE WITH SPECIFIC ANCHORS BEING | | | USED FOR STORM PANELS PRIOR TO | | | INSTALLATION. | | | | | | 2)DOUBLE OUTSWING GLAZED METAL DOORS ARE | | | TO BE INSTALLED WITHOUT SIDELITES AS PER | | | PRODUCT APPROVALS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2000-10-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-10-27 |
Time |
10:35 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM BEACH | | | CO.,PLANS STAMPED BY THEM AND RECEIPT | | | SUBMITTED TO CITY OF WPB BUILDING DEPT. | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR EXTERIOR | | | FRENCH DOORS W/SIDELITES AS SHOWN ON | | | PLANS. | | | | | | 3)PROVIDE INSTALLATION SCHEDULE AND KEY | | | PLAN INDICATING WINDOWS AND DOORS THAT | | | WILL RECEIVE STORM PANELS. | | | | | | 4)ARCHITECT TO DATE AND PROVIDE LEGIBLE | | | NAME AND REGISTRATION NUMBER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-09-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-09-28 |
Time |
08:07 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY,PLANS STAMPED BY THEM AND RECEIPT | | | SUBMITTED TO CITY OF WPB BLDG. DEPT. | | | | | | 2)PROVIDE ATTIC ACCESS PER 97 SBC 2309.6 | | | | | | 3)BATHROOM WINDOWS MUST COMPLY WITH | | | SAFETY GLAZING REQUIREMENTS PER 97 SBC | | | 2405.2. | | | | | | 4)PLEASE SPECIFY TRUSS ANCHORS FOR TRUSS | | | -ES AT REAR WITH 705# UPLIFT. | | | | | | 5)NOTE 5 ON SHEET S-1 IS INCORRECT. THE | | | WINDLOAD FOR PALM BEACH CO. IN ASCE7-95 | | | IS 140 MPH,NOT 110 MPH. PLEASE RECHECK | | | YOUR CALCULATIONS. | | | | | | 6)IF STRUCTURE IS NOT DESIGNED BY AN | | | ARCHITECT OR ENGINEER,THE DESIGN MUST | | | CONFORM TO SSTD 10-97,WHICH IS THE | | | PRESCRIPTIVE STANDARD ADOPTED BY THE | | | CITY OF WPB. CITY AMENDMENTS TO 97 SBC. | | | SEC.104.2.3. PLEASE REVIEW PLANS FOR | | | COMPLIANCE WITH SSTD 10-97 AND DO NOT | | | SITE OTHER DESIGN CRITERIA ON PLANS. | | | IF DESIGNED BY ARCHITECT OR ENGINEER | | | PLANS MUST BE SIGNED,SEALED AND DATED. | | | | | | 7)PROVIDE EAST AND WEST ELEVATIONS | | | SHOWING ALL OPENINGS IN NEW AND EXISTING | | | STRUCTURE,SO THAT THE PERCENTAGE OF | | | ALLOWABLE OPENINGS CAN BE DETERMINED PER | | | 97 SBC TABLE 600. | | | | | | 8)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR FRENCH | | | DOORS WITH SIDELITES AS SHOWN ON REAR | | | ELEVATION ON PLANS. IMPACT GLASS OR | | | OTHER IMPACT PROTECTION WILL BE REQUIRED | | | | | | 9)PROVIDE KEY PLAN AND INSTALLATION | | | SCHEDULE,WITH SPECIFIC ANCHORS TO BE | | | USED,FOR STORM PANELS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-09-09 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-09-09 |
Time |
07:50 |
Rev Time |
0.15 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|