Plan Review Details - Permit 00081655
Plan Review Stops For Permit 00081655
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-10-30 Cont ID  
Sent By dpalmer Date 2000-10-30 Time 12:08 Rev Time 0.00
Received By dpalmer Date 2000-10-30 Time 12:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-09-21 Cont ID  
Sent By dpalmer Date 2000-09-21 Time 22:59 Rev Time 0.00
Received By dpalmer Date 2000-09-21 Time 22:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-06-13 Cont ID  
Sent By pkrauss Date 2001-06-13 Time 14:46 Rev Time 0.45
Received By pkrauss Date 2001-06-13 Time 14:36 Sent To  
Notes
2001-06-13 00:00:00REVISION - EQUIPMENT UPGRADE (3 TON)

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-09-16 Cont ID  
Sent By jleech Date 2000-09-16 Time 08:22 Rev Time 0.33
Received By jleech Date 2000-09-16 Time 08:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-09-10 Cont ID  
Sent By pschmitz Date 2000-09-10 Time 13:38 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-11-20 Cont ID  
Sent By fknapp Date 2000-11-20 Time 14:40 Rev Time 4.00
Received By fknapp Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-10-30 Cont ID  
Sent By jgomez Date 2000-10-30 Time 19:15 Rev Time 2.50
Received By jgomez Date 2000-10-30 Time 19:14 Sent To  
Notes
2001-01-08 00:00:00SECOND CHECKLIST:
 1-IMPACT FEES STILL NOT PAID.
 2-SECOND FLOOR WINDOWS IN BEDROOM #2
 DON'T COMPLY WITH SECTION 1005.4.4 OF
 SBC 1997. MINIMUM CLEAR OPENING TO BE
 5.7 SQ. FT.(26 1/2"BY 31 1/2" WINDOW
 DON'T PROVIDE THE MINIMUM CLEAR
 OPENING)
 -SIZE OF WINDOW SPECIFIED ON DWG A-1.0
 IS NOT CLEAR? WHAT IS (3)1H5 SH.? SEE
 PLANS.
 3-PROVIDE SIGNED AND SEALED SOIL TEST
 REPORT FOR THIS LOT. SEE ORIGINAL SOIL
 TEST REPORT FOR RECOMMENDATIONS.
 -IF ORGANIC MATERIALS ARE PRESENT, THEN
 THEY NEED TO BE REMOVED.SEC 1804.1.8
 OF SBC 1997.
 4-PROVIDE PRODUCT APPROVALS FOR:
 -SKYLIGHT (EXPIRED).
 -FLAT ROOF SYSTEM.
 -ENTRY DOOR WITH SIDELITE ASSEMBLY WITH
 COMPLETE AND LEGIBLE DRAWINGS.
 -WINDOW MULLIONS.
 -ONE HOUR GLASS BLOCK.
 -SLIDING GLASS DOOR WITH TRANSOM ABOVE
 ASSEMBLY.
 5-TRUSS DRAWINGS:
 -TRUSS ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE WHEN SUBMITTING DOCUMENTS
 FOR PUBLIC RECORDS AS PER CHAPTER 471
 OF FLORIDA STATUTES.
 -TRUSS ENGINEER TO UPDATE ALL GENERAL
 DETAILS AND SIGN, SEAL AND DATE THEM.
 DON'T PROVIDE COPIES SIGNED BY ANOTHER
 ENGINEER. DRAWINGS TO BE LEGIBLE ALSO.
 -TRUSS ENGINEER TO REVISE FLOOR TRUSSES
 BY THE FOYER AREA AS PER INSTRUCTIONS
 OF ENGINEER OF RECORD. SEE SHEET S-1.
 -ENGINEER OF RECORD TO REVIEW ALL TRUSS
 DRAWINGS PRIOR TO SUBMITTAL TO THIS
 OFFICE.
 *NOTE: SHOP DRAWINGS REVIEW STAMP
 BY ENGINEER OF RECORD DOESN'T SHOW THE
 NAME OF THE COMPANY REVIEWING THE
 SHOP DRAWINGS.
 6-ENGINEER OF RECORD TO SPECIFY ALL
 CONNECTORS. SEE ROOF FRAMING PLAN FOR
 COMMENTS.
 7-PROVIDE BUCK DETAIL FASTENING FOR A
 2X BUCK. PRODUCTAPPROVAL FOR DOORS
 AND WINDOWS REQUIRE A 2X BUCK. SEE
 PRODUCT APPROVALS.
 8-STORM PANELS:
 -PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS.
 -THIS MAY BE SUBMITTED LATER UNDER A
 SEPARATE PERMIT.
 9-REVISE SIZE OF CEILING FANS. SEE TABLE
 6-6 OF FLORIDA ENERGY EFFICIENCY CODE
 FOR BUILDING CONSTRUCTION. 1997 ED.
 10-SEE COMMENTS ON PLANS, INCLUDING
 COMMENTS BY THE OTHER TRADES AND
 REVISE ORIGINALS AS REQUIRED.
  
  
  
  
 NOTES:
 -PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO ORIGINALS IN
 ORDER TO EXPEDITE THE REVIEW PROCESS.
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.
  
  
 ****CONTRACTOR TO RENEW LICENSE.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-09-27 Cont ID  
Sent By jgomez Date 2000-09-27 Time 18:59 Rev Time 5.00
Received By jgomez Date 2000-09-27 Time 18:58 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-PROVIDE SAFETY GLASS AT BREAKFAST
 WINDOW. SEE PLANS. SEC. 2405.2 SBC/97.
 3-EGRESS WINDOWS AT BEDROOM #2 DON'T
 COMPLY WITH SECTION 1005.4.4 SBC 1997.
 -SIZE OF WINDOW SPECIFIED FOR BEDROOM
 #2 IS NOT CLEAR.
 4-STRUCTURAL ENGINEER TO SEE SOIL TEST
 REPORT FOUNDATION RECOMMENDATIONS. IT
 SAYS THAT "EXTERIOR FOUNDATIONS SHOULD
 BEAR AT LEAST 18 INCHES BELOW ADJACENT
 OUTSIDE FINAL GRADES". REVISE FOOTINGS
 SIZE AS RECOMMENDED OR PROVIDE LETTER
 CERTIFYING THAT HE READ THE SOIL TEST
 REPORT AND HIS DESIGN IS ADEQUATE TO
 THE SITE CONDITIONS.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 5-PROVIDE SIGNED, SEALED AND DATED SOIL
 TEST REPORT. CHAPTER 471 FL. STATUTES.
 6-PROVIDE ATTIC ACCESS AT GARAGE AREA.
 SECTION 2309.6 SBC 1997.
 7-PROVIDE PRODUCT APPROVALS FOR:
 -SKYLIGHT (EXPIRED)
 -FLAT ROOF SYSTEM.
 -ENTRY DOOR WITH SIDELITE ASSEMBLY AND
 APPROVED DWGS TO BE LEGIBLE & COMPLETE
 -WINDOW MULLIONS
 -ONE HOUR GLASS BLOCK.
 -SLIDING GLASS DOOR WITH TRANSOM ABOVE
 ASSEMBLY.
 8-PROVIDE COMPLETE SECTION AT GABLE END
 WALLS. SPECIFY ALL FASTENERS. SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 9-TRUSS DRAWINGS:
 -TRUSS ENGINEER TO PROVIDE ORIGINAL
 SIGNATURE AT ALL DOCUMENTS SUBMITTED
 FOR PUBLIC RECORDS. CHAPTER 471 FL. ST
 -TRUSS ENGINEER TO UPDATE ALL GENERAL
 DETAILS AND SIGN, SEAL AND DATE THEM.
 ALSO, MAKE THEM LEGIBLE.
 -TRUSS ENGINEER TO REVISE FLOOR TRUSSES
 BY THE FOYER AREA AS PER INSTRUCTIONS
 OF ENGINEER OF RECORD ON SHEET S-1.
 -ENGINEER OF RECORD TO REVIEW TRUSS
 LAYOUT AND ENGINEERED DRAWINGS PRIOR
 TO SUBMITTAL TO THIS OFFICE.
 *NOTE: SHOP DRAWING REVIEW STAMP NEEDS
 TO SPECIFY WHO OR WHAT FIRM REVIEWED.
 10-PROVIDE BUCK DETAIL FASTENING FOR A
 2X BUCK. PRODUCT APPROVALS FOR DOORS
 AND WINDOWS SUBMITTED CALL FOR
 ATTACHMENT TO 2X BUCKS.
 11-STORM PANELS:
 -INSTALLATION SCHEDULE SUBMITTED IS FOR
 ANOTHER MODEL. ALSO: USE CITY SAMPLE
 ATTACHED AND FILL IN ALL INFORMATION
 CORRECTLY.Y PLAN
 -PROVIDE KEY PLAN.
 12-SEE COMMENTS ON PLANS, INCLUDING
 COMMENTS BY THE OTHER TRADES AND
 REVISE ORIGINALS AS REQUIRED.
  
  
 NOTES:
 -CONTRACTOR TO UPDATE THE LICENSE.
 -RETURN REVIEWED AFTER ALL CORRECTIONS
 ARE DONE TO ORIGINAL DRAWINGS IN ORDER
 TO EXPEDITE THE REVIEW PROCESS.
 -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-09-09 Cont ID  
Sent By gjoyce Date 2000-09-09 Time 07:42 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy