Plan Review Details - Permit 00081579
Plan Review Stops For Permit 00081579
Review Stop FS  
Rev No 1 Status P Date 2000-09-15 Cont ID  
Sent By mcarsill Date 2000-09-15 Time 13:11 Rev Time 0.00
Received By mcarsill Date 2000-09-15 Time 13:11 Sent To  
Notes
2001-01-08 00:00:001) BUILDING #5-D IS TO HAVE A SEPARATE
 FIRE DEPARTMENT CONNECTION.
 2) GARAGE DOORS WHEN OPENED ARE NOT TO
 INTERFERE WITH FIRE SPRINKLER OPERATION
 IN THE GARAGES.
 3) SOFFITS ARE NOT TO INTERFERE WITH
 FIRE SPRINKLER HEAD DISCHARGE.
 4) TOWNHOUSE UNITS ARE TO BE SEPARATED
 FROM ONE ANOTHER BY AT LEAST TWO HOUR
 FIRE WALLS.
 5) FIRE SPRINKLERS CANNOT BE OMITTED
 FROM ENTRY FOYER IF THAT IS THE ONLY
 MEANS OF EGRESS.
 APPROVED PROVISO: