| Plan Review Stops For Permit 00081069 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-02-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-13 |
Time |
10:19 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-13 00:00:00 | PROVISO: STORM SHUTTERS WILL BE ISSUED | | | UNDER A SEPERATE PERMIT, WITH FEES. SITE | | | SPECIFIC DATA ON WINDOWS VS. DEFLECTION | | | TO BE INCLUDED. | | | MARCH 13,01 THE BUILDING OFFICIAL | | | REJECTED THE PROPOSED SITE SPECIFIC | | | STORM SHUTTER PROPOSAL, THE PRODUCT MUST | | | BE TESTED AS THE PROPOSED INSTALLATION | | | TO SHOW IT WILL PROTECT THE GLAZED OPEN- | | | INGS AS PER CITY ORDINANCE. JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2001-02-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-02 |
Time |
10:59 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-02 00:00:00 | 700 S. OLIVE | | | EUROPA BUILDING ASSOC. | | | | | | 1) A NEW NOTICE OF COMMENCEMENT REQUIRED | | | PERMIT NOT ISSUED AFTER 90 DAYS OF | | | BEING RECORDED. | | | 2) CONTRACTOR TO SIGN ENERGY CALS. | | | 3) PLANS TO BE REVIEWED BY PALM BEACH CO | | | FOR IMPACT FEES, AND STAMP PLANS. | | | 4) LETTER FROM ENGINEER CERTIFYING THE | | | INSTALLTION OF WINDOWS, SIGNED& SEALED | | | 5) PRODUCT WIWNDOW FORM SEALED BY THE | | | ENGINEER OF THE WINDOW MAN. & ENG. OF | | | RECORD. | | | 6) APPROVAL FROM BUILDING OFFICIAL FOR | | | PRE EXISTING CONDITION SBC CHAP 34 | | | EXISTING BUILDINGS. | | | 7) ZONING APPROVAL JOE MINACOZZI |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-01-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-01-18 |
Time |
12:52 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2001-01-18 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2001-01-18 00:00:00 | REVIEWED WITH CONTRACTOR 01/18/01 | | | ITEM#2 COUNTY IMPACT FEES TO BE ADDRESS- | | | ED. | | | | | | ITEM # 4 ARMOR SCREEN NEEDS SH 1-6 TECH | | | DRAWINGS. | | | | | | ITEM #6 ENGINEER TO CERTIFY THE WINDOW | | | INSTALATION THERE WAS NO INSPECTION ON | | | THESE TWO PRMITS. | | | | | | ITEM #8 CONTRACTOR TO PLACE SLAB AT | | | STAIRWELL "B" TO BRING IT UP TO THE SAME | | | LEVEL. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-09-26 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-09-26 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING COMMENTS | | | ------------------- | | | | | | 1] PROVIDE ACCESSIBILITY TO ELEVATOR | | | LOBBY. | | | 2] PLANS SHALL BE REVIEWED BY THE PALM | | | BEACH COUNTY IMPACT FEE CORDINATOR. | | | 3] SPECIFY SINGLE TENANT BUILDING OR | | | PROVIDE RATED DOORS AT CORRIDORS. | | | 4] SUBMIT PRODUCT TEST REPORTS FOR ANY | | | NEW EXTERIOR DOORS OR WINDOWS. | | | 5] PLEASE EXPLAIN COMMENT AT THE BOTTOM | | | OF SHEET A2.03,"MISSLE IMPACT STANDARD | | | 6] THE RESPONSIBILTY OF 2 PREVIOUS | | | PERMITS[97002184 AND 00030093]SHALL BE | | | ADDRESSED AND COME TO SOME CONCLUSION | | | BEFORE THE ISSUANCE OF THIS PERMIT. | | | 7] SHEET S.2 IS MISSING,PLEASE SUBMIT | | | FOR REVIEW,PROVIDE SPECS FOR SPIRAL | | | STAIR. | | | 8] PROVIDE UNOBSTRUCTED LEVEL MEANS OF | | | EGRESS AT STAIR "B",SEE 1012.1.3 SBC | | | SHOW EXTERIOR AREA OUTSIDE OF STAIR B. | | | DOOR#44 SHALL BE RATED,SEE DOOR SCHED. | | | 9] STATE STATUE 553.895 REQUIRES THE | | | BUILDING TO BE FULLY SPRINKLED. | | | 10] EXISTING STAIR "A" SHALL BE SEPERATE | | | AND PROTECTED FROM THE REMAINDER OF | | | THE BUILDING,1006.1 SBC. | | | | | | | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 561-659-8096 | | | EXT:8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2001-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-05 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-05 |
Time |
18:57 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-15 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-15 |
Time |
07:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2001-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-01 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-01 |
Time |
18:26 |
Sent To |
|
|
| Notes |
| 2001-02-01 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT PANEL | | | SCHEDULES ARE STILL NOT | | | LABELED,,"A"B"C"ETC. | | | | | | 2)NOTE: PLEASE CLARIFY WHERE LOAD | | | CALCULATIONS SHOW ALL CONTINUOUS LOADS | | | AT 125%??. PLEASE CLARIFY THE NOTE ON | | | PANELS | | | "LOAD COMPUTERS@125%" ??? | | | PLEASE SHOW LOAD CALCS PER 220. | | | | | | 3)NOTE: PLEASE NOTE TYPE-O FOR A/C | | | RATINGS OF EQUIPMENT.NEEDS TO SHOW | | | "AIC" | | | ALSO PLEASE NOTE THAT ALL EQUIPMENT IS | | | BEING SHOWN AT 100,000 AIC RATED! YET | | | THEAVAILABLE FAULT CURRENT IS SHOWN | | | LESSTHAN 10,000 AND 22,000 AVAILABLE? | | | PLEASENOTE IF PLANS SHOW 100,000 THEN | | | 100,000 RATED EQUIPMENT WILL HAVE TO BE | | | INSATLLED. JUST A NOTE 100,000 RATED | | | EQUIPMENT | | | CAN BE 4,5,6 TIMES MORE IN PRICE THAN | | | WHAT IS BEING NEEDED FROM CALCULATIONS | | | ON E2.02. JUST A NOTE. | | | | | | 4)NOTE:PLEASE SHOW ALL BRANCH CIRCUIT | | | `SFOR ALL, INCLUDING DETACHED BUILDING | | | SHOWN ON E2.00. PLEASE CLARIFY WHERE | | | POWER IS COMING FROM AND MEANS OF | | | DISCONNECT PER 225-31. GROUNDING PER | | | DETACHED BUILDING? | | | | | | 5)NOTE: PLEASE CLARIFY CIRCUITS FOR | | | COMMON AREAS COMING FROM TENANT PANELS. | | | WHERE IS HOUSE PANEL? WHY ARE CIRCUITS | | | ON FIRST FLOOR COMING FROM PANEL/TENANT | | | FROM THIRD FLOOR????? SECOND FLOOR ETC?? | | | | | | 6) PLEASE NOTE MISSING OUTLET FOR A/C | | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | | MECHANICAL CODE. | | | | | | 7)NOTE: PLEASE SHOW LOCATIONS OF ALL | | | SERVICE EQUIPMENT. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. PLEASE CALL IF THERE ARE | | | ANYQUESTIONS OR CALL TO SET UP AN | | | APPOINTMENT TO CLARIFY ANY ISSUES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-01-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-10 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-09 |
Time |
20:00 |
Sent To |
|
|
| Notes |
| 2001-01-10 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: AS ASKED FOR ON PREVIOUS REVIEW, | | | PLEASE SHOW ALL BRANCH CIRCUIT#`S ON | | | PLANS AND CORRELATE WITH PANEL | | | SCHEDULES. | | | | | | 2)NOTE: PLEASE SHOW THE AIC RATINGS OF | | | EACH PIECE OF EQUIPMENT ON PLAN. FAULT | | | CURRENT IS SHOWN BUT JUST NEEDS TO HAVE | | | THE RATINGS SHOWN. | | | | | | 3)NOTE: PLEASE LABEL ALL PANELS IE. | | | "A","B", "C" ETC ETC | | | ALSO PLEASE SEE PLANS, PLANS SHOW 6 | | | PANELS AND ONLY 3 PANEL SCHEDULES WERE | | | SUBMITTED.? A,B,C SHOWN AND D,E,F IS | | | NOT SHOWN. ???? | | | | | | 4)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | ATE 125%. (LIGHTING) IF LOADS ON PANEL | | | SCHEDULE ARE AT 125% ALREADY THEN PLEASE | | | INDICATE THIS. | | | | | | 5)NOTE: PLEASE SHOW OR CLARIFY THE | | | GROUNDING ELECTRODE CONDUCTOR, BLDG | | | STEEL, COLD WATER. PER 250-50 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS PLEAS | | | E CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-09-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-14 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-14 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT PLANS SHOWING ALL | | | BRANCH CIRCUIT #`S AND CORRELATE WITH | | | PANEL SCHEDULES | | | | | | 2)NOTE: PLEASE SHOW DETAIL ON PANELS | | | BEING INSTALLED. | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL EQUIPMENT BEING INSTALLED.MAINS/ | | | PANELS/BREAKERS. 110-9 AND 215-5 | | | | | | 4)NOTE:PLEASE SEE BOTTOM OF PANEL/LOAD | | | SCHEDULE SHOWN. YOU SHOW SERVICE TO BE | | | FURNISHED AS 400AMP. IS THIS GOING TO BE | | | BYTWO SEPARATE SERVICES?PLEASE SEE | | | NEC FOR TWO SERVICES SERVING ONE SPACE. | | | | | | 5)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. LIGHTING ETC. | | | | | | 6)NOTE: PLEASE SHOW WIRE SIZES,BRKR SIZE | | | -S ETC FOR PANEL SCHEDULES. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-30 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-14 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-02-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-05 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-13 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2001-02-13 00:00:00 | 1) PROVIDE COMPLETE FIRE SPRINKLER | | | AND FIRE ALARM DRAWINGS PRIOR TO | | | STARTING TO INSTALLATION. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-02-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-05 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-05 |
Time |
13:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-12-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-12-28 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-12-28 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS TO | | | COMPLY WITH CITY CODE REQUIREMENTS. | | | 2) PLEASE INDICATE IN WRITING IF THE | | | EXISTING FIREPLACE WILL BE USED OR IS | | | ONLY FOR ORNAMENTAL LOOK. | | | 3) THE FIRE SPRINKLER SYSTEM | | | INSTALLATION IS REQUIRED TO HAVE A | | | SEPARATE PLAN AND PERMIT PRIOR TO | | | INSTALLATION. | | | 4) THE FIRE ALARM SYSTEM DRAWING | | | INDICATES OPTIONAL CENTRAL STATION | | | MONITORING. CENTRAL STATION MONITORING | | | IS REQUIRED BY BOTH BUILDING AND FIRE | | | CODE REQUIREMENTS. | | | | | | NOTE: ON DECEMBER 29,2000, THIS WRITER | | | ALONG WITH CHEIF BUILDING INSPECTOR | | | LOU HATTEN WILL VISIT THE BUILDING TO | | | EXAMINE EXISTING ISSUES RELATING TO THE | | | BUILDING. | | | | | | APPROVED PROVISO: | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-23 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-08-23 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. THE CODE RESEARCH BOX | | | INDICATES FIRE SPRINKLERS ARE PRESENT | | | IN THE CORRIDORS ONLY. | | | 2) NO FIRE ALARM SYSTEM SHOWN ON | | | DRAWINGS. PLEASE BE ADVISED THAT SINCE | | | THE BUILDING IS THREE STORIES HIGH, A | | | FIRE ALARM SYSTEM IS REQUIRED. PLEASE | | | NOTE THAT THE EXISTING FIRE SPRINKLER | | | SYSTEM SHOULD BE SUPERVISED IN | | | ACCORDANCE WITH BUILDING AND FIRE CODE | | | REQUIREMENTS. | | | 3) ALL STORAGE, EQUIPMENT, AND | | | MECHANICAL ROOMS IF NOT FIRE SPRINKLER | | | PROTECTED TO BE AT LEAST ONE HOUR FIRE | | | RATED WITH C LABELED FIRE DOORS WITH | | | SELF-CLOSING DEVICES. | | | 4) PLEASE PROVIDE MORE INFORMATION ON | | | SIX INCH STEP NEAR STAIR B. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2002-10-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-10-30 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-10-29 |
Time |
11:11 |
Sent To |
FIRE |
|
| Notes |
| 2002-10-30 00:00:00 | TO FIRE IN BOX./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2001-11-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-05 |
Time |
09:49 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-11-05 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2001-11-05 00:00:00 | NOTES ON MECH PERMIT 00090058 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-18 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-01-18 |
Time |
10:48 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2001-01-18 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2001-01-18 00:00:00 | PROVISO: | | | OUTSIDE AIR INTAKE FROMHEAT WHEEL | | | TO BE MIN. 10 FT FROMEXHAUST OUTLET | | | PER 1997 SMC 406 OR EXHAUST OUTLET | | | SHALL BE MIN. TWO FT ABOVE AIR INTAKE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-09-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-06 |
Time |
09:16 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-09-06 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************DENIED******************** | | | 1. PROVIDE INFORMATION ON LOCATION AND | | | OPERATION OF HEAT WHEEL | | | 2. PROVIDE INFORMATION ON CONDENSATE | | | DRAIN INSTALLATION | | | 3. PROVIDE INFORMATION ON SEQUENCE OF | | | OPERATION ESP. O/A DAMPER. DAMPER SHALL | | | NOT REDUCE QUANTITY OF OUTSIDE AIR BELOW | | | ASHRAE 62-89 REQUIRED VALUES DURING | | | OCCUPIED TIMES | | | 4. FIRE DAMPERS NOT SHOWN AT ALL RATED | | | WALL PENETRATIONS. 1997 SMC 610.6 | | | REQUIRES LOCATION AND INSTALLATION | | | DETAILS ON THE BUILDING PLANS | | | 5.NO VENTILATION SHOWN FOR COMMON AREAS | | | 6. PROVIDE DETAILS ON SHAFTS SHOWING | | | COMPLIANCE WITH 1997 SMC 610.4 | | | 7. FAN SHUT DOWN BY DUCT SMOKE DETECTORS | | | REQUIRED PER 1997 SMC 406. | | | 8. NOTE: CONDENSING UNITS ARE TO BE | | | MOUNTED ON SOLID CONCRETE PADS MINIMUM | | | 3" ABOVE FINISHED GRADE. SERVICE ACCESS | | | AND ELECTRICAL ACCESS TO COMPLY WITH SMC | | | AND THE NATIONAL ELECTRIC CODE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-01-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-30 |
Time |
15:10 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
2001-01-30 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-08 |
Time |
11:50 |
Rev Time |
2.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED; | | | | | | 1.NOTE 20. CONDENSATE OVER 3 TONS MUST | | | GO TO DRYWELL OR STORM SMC 304.8.3. | | | | | | 2.NOTE 25. CLEANOUTS MUST BE NOT MORE | | | THAN 80' FOR FOUR INCH. PIPE SPC 710.1 | | | | | | 3.PLUMBING RISER DIAGRAM NOT TO CODE; | | | A.MAIN VENT SHOULD COMPLY WITH SPC | | | 918. | | | B.VENT STACK SHOULD TIE INTO WASTE | | | STACK 6" ABOVE HIGHEST FIXTURE AS | | | MAIN VENT. | | | C.WHERE DOES WASTE GO FROM W/C AND | | | LAV. LEFT SIDE OF DIAGRAM ALL | | | THREE FLOORS? | | | | | | 4.(WATER RISER) COLD WATER MAIN GOES | | | FROM 1 1/2 TO 1 1/4 BACK TO 1 1/2 | | | PLEASE RE-SIZE. | | | | | | 5.SHOW HOT WATER RISER FROM FIRST FLOOR | | | TO THIRD FLOOR. | | | | | | 6.AIR CHAMBERS TO COMPLY WITH SPC | | | 607.8.3. | | | | | | 7.SHOW SIZE AND TYPE OF WATER HEATER. | | | | | | 8.DRINKING FOUNTAINS SHALL COMPLY WITH | | | FACBC 4.1.3(10) (A) 415. PROVIISIONS | | | SHALL BE MADE FOR PEOPLE WHO HAVE | | | TROUBE BENDING OR STOOPING. | | | | | | 9.HANDICAP STALLS (MENS ROOM) ALL THREE | | | FLOORS MUST BE 66" WIDE FOR CLEAR | | | FLOOR SPACE 36" FOR W/C AND 30" FOR | | | LAVITORYS. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-26 |
Time |
11:48 |
Rev Time |
0.85 |
| Received By |
pschmitz |
Date |
2000-08-26 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)ACCESSIBLE TOILET ROOMS WITHIN THE | | | RESTROOM SHALL COMPLY W/FACBC SEC.4.17.3 | | | MIN.WIDTH SHALL BE 83"IF LAV.IS ADJACENT | | | TO W.C.IF YOU DISAGREE CALL THE DEPT.OF | | | COMMUNITY AFFAIRS AT 850-487-1824 FOR | | | AN INTERPRETATION. | | | | | | 2)BREAK ROOM COUNTERS AND SINK SHALL | | | COMPLY W/FACBC SEC.4.24.1-4.24.7. | | | | | | 3)DRINKING FOUNTAINS ARE REQD.ON EACH | | | FLOOR PER TABLE 407 OF SPC.FOUNTAINS | | | SHALL COMPLY W/FACBC SECS.4.1.3.(10)(A). | | | 4.15.PROVISIONS SHALL BE MADE FOR PEOPLE | | | WHO HAVE TROUBLE BENDING OR STOOPING. | | | | | | 4)FLOOR DRAINS ARE REQD.IN THE TOILET | | | ROOMS PER SPC SEC.409.4.1.1.DRAINS SHALL | | | BE EQUIPPED W/TRAP PRIMERS. | | | | | | 5)ALL EXPOSED PIPES AND SURFACES SHALL | | | BE INSULATED PER FACBC SEC.4.19.4.(SEE | | | SHT.A5). | | | | | | 6)SHT.A5-FIXTURE COUNT SHALL BE BASED ON | | | THE 1994 STANDARD PLUMBING CODE,NOT 1997 | | | | | | 7)SUBMIT A WATER ISOMETRIC FOR REVIEW | | | THAT COMPLIES W/SPC 1994 EDITION IN ALL | | | RESPECTS. | | | | | | 8)SUBMIT A NEW SANITARY ISOMETRIC FOR | | | REVIEW.THE ONE SUBMITTED HAS FAR TOO | | | MANY VIOLATIONS TO LIST.COMPLY W/SPC. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-02-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-16 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-16 00:00:00 | PASSED PER A.G. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2000-10-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-10-02 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2000-09-27 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTES PER MINICOZZI | | | | | | PLEASE SCREEN MECHANICAL EQUIPMENT PER | | | ZONING CODE |
|
|