Plan Review Details - Permit 00081069
Plan Review Stops For Permit 00081069
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2001-02-13 Cont ID  
Sent By jwitmer Date 2001-02-13 Time 10:19 Rev Time 4.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-02-13 00:00:00PROVISO: STORM SHUTTERS WILL BE ISSUED
 UNDER A SEPERATE PERMIT, WITH FEES. SITE
 SPECIFIC DATA ON WINDOWS VS. DEFLECTION
 TO BE INCLUDED.
 MARCH 13,01 THE BUILDING OFFICIAL
 REJECTED THE PROPOSED SITE SPECIFIC
 STORM SHUTTER PROPOSAL, THE PRODUCT MUST
 BE TESTED AS THE PROPOSED INSTALLATION
 TO SHOW IT WILL PROTECT THE GLAZED OPEN-
 INGS AS PER CITY ORDINANCE. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-02-02 Cont ID  
Sent By jwitmer Date 2001-02-02 Time 10:59 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-02-02 00:00:00700 S. OLIVE
 EUROPA BUILDING ASSOC.
  
 1) A NEW NOTICE OF COMMENCEMENT REQUIRED
 PERMIT NOT ISSUED AFTER 90 DAYS OF
 BEING RECORDED.
 2) CONTRACTOR TO SIGN ENERGY CALS.
 3) PLANS TO BE REVIEWED BY PALM BEACH CO
 FOR IMPACT FEES, AND STAMP PLANS.
 4) LETTER FROM ENGINEER CERTIFYING THE
 INSTALLTION OF WINDOWS, SIGNED& SEALED
 5) PRODUCT WIWNDOW FORM SEALED BY THE
 ENGINEER OF THE WINDOW MAN. & ENG. OF
 RECORD.
 6) APPROVAL FROM BUILDING OFFICIAL FOR
 PRE EXISTING CONDITION SBC CHAP 34
 EXISTING BUILDINGS.
 7) ZONING APPROVAL JOE MINACOZZI

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-01-18 Cont ID  
Sent By jwitmer Date 2001-01-18 Time 12:52 Rev Time 2.00
Received By jwitmer Date 2001-01-18 Time 12:52 Sent To  
Notes
2001-01-18 00:00:00REVIEWED WITH CONTRACTOR 01/18/01
 ITEM#2 COUNTY IMPACT FEES TO BE ADDRESS-
 ED.
  
 ITEM # 4 ARMOR SCREEN NEEDS SH 1-6 TECH
 DRAWINGS.
  
 ITEM #6 ENGINEER TO CERTIFY THE WINDOW
 INSTALATION THERE WAS NO INSPECTION ON
 THESE TWO PRMITS.
  
 ITEM #8 CONTRACTOR TO PLACE SLAB AT
 STAIRWELL "B" TO BRING IT UP TO THE SAME
 LEVEL.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-09-26 Cont ID  
Sent By lmartine Date 2000-09-26 Time 14:45 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00BUILDING COMMENTS
 -------------------
  
 1] PROVIDE ACCESSIBILITY TO ELEVATOR
 LOBBY.
 2] PLANS SHALL BE REVIEWED BY THE PALM
 BEACH COUNTY IMPACT FEE CORDINATOR.
 3] SPECIFY SINGLE TENANT BUILDING OR
 PROVIDE RATED DOORS AT CORRIDORS.
 4] SUBMIT PRODUCT TEST REPORTS FOR ANY
 NEW EXTERIOR DOORS OR WINDOWS.
 5] PLEASE EXPLAIN COMMENT AT THE BOTTOM
 OF SHEET A2.03,"MISSLE IMPACT STANDARD
 6] THE RESPONSIBILTY OF 2 PREVIOUS
 PERMITS[97002184 AND 00030093]SHALL BE
 ADDRESSED AND COME TO SOME CONCLUSION
 BEFORE THE ISSUANCE OF THIS PERMIT.
 7] SHEET S.2 IS MISSING,PLEASE SUBMIT
 FOR REVIEW,PROVIDE SPECS FOR SPIRAL
 STAIR.
 8] PROVIDE UNOBSTRUCTED LEVEL MEANS OF
 EGRESS AT STAIR "B",SEE 1012.1.3 SBC
 SHOW EXTERIOR AREA OUTSIDE OF STAIR B.
 DOOR#44 SHALL BE RATED,SEE DOOR SCHED.
 9] STATE STATUE 553.895 REQUIRES THE
 BUILDING TO BE FULLY SPRINKLED.
 10] EXISTING STAIR "A" SHALL BE SEPERATE
 AND PROTECTED FROM THE REMAINDER OF
 THE BUILDING,1006.1 SBC.
  
  
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 561-659-8096
 EXT:8456

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-11-05 Cont ID  
Sent By dpalmer Date 2001-11-05 Time 18:57 Rev Time 0.00
Received By dpalmer Date 2001-11-05 Time 18:57 Sent To FIRE
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-02-15 Cont ID  
Sent By dpalmer Date 2001-02-15 Time 07:52 Rev Time 0.00
Received By dpalmer Date 2001-02-15 Time 07:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-02-01 Cont ID  
Sent By dpalmer Date 2001-02-01 Time 18:26 Rev Time 0.00
Received By dpalmer Date 2001-02-01 Time 18:26 Sent To  
Notes
2001-02-01 00:00:00*************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT PANEL
 SCHEDULES ARE STILL NOT
 LABELED,,"A"B"C"ETC.
  
 2)NOTE: PLEASE CLARIFY WHERE LOAD
 CALCULATIONS SHOW ALL CONTINUOUS LOADS
 AT 125%??. PLEASE CLARIFY THE NOTE ON
 PANELS
 "LOAD COMPUTERS@125%" ???
 PLEASE SHOW LOAD CALCS PER 220.
  
 3)NOTE: PLEASE NOTE TYPE-O FOR A/C
 RATINGS OF EQUIPMENT.NEEDS TO SHOW
 "AIC"
 ALSO PLEASE NOTE THAT ALL EQUIPMENT IS
 BEING SHOWN AT 100,000 AIC RATED! YET
 THEAVAILABLE FAULT CURRENT IS SHOWN
 LESSTHAN 10,000 AND 22,000 AVAILABLE?
 PLEASENOTE IF PLANS SHOW 100,000 THEN
 100,000 RATED EQUIPMENT WILL HAVE TO BE
 INSATLLED. JUST A NOTE 100,000 RATED
 EQUIPMENT
 CAN BE 4,5,6 TIMES MORE IN PRICE THAN
 WHAT IS BEING NEEDED FROM CALCULATIONS
 ON E2.02. JUST A NOTE.
  
 4)NOTE:PLEASE SHOW ALL BRANCH CIRCUIT
 `SFOR ALL, INCLUDING DETACHED BUILDING
 SHOWN ON E2.00. PLEASE CLARIFY WHERE
 POWER IS COMING FROM AND MEANS OF
 DISCONNECT PER 225-31. GROUNDING PER
 DETACHED BUILDING?
  
 5)NOTE: PLEASE CLARIFY CIRCUITS FOR
 COMMON AREAS COMING FROM TENANT PANELS.
 WHERE IS HOUSE PANEL? WHY ARE CIRCUITS
 ON FIRST FLOOR COMING FROM PANEL/TENANT
 FROM THIRD FLOOR????? SECOND FLOOR ETC??
  
 6) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
  
 7)NOTE: PLEASE SHOW LOCATIONS OF ALL
 SERVICE EQUIPMENT.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. PLEASE CALL IF THERE ARE
 ANYQUESTIONS OR CALL TO SET UP AN
 APPOINTMENT TO CLARIFY ANY ISSUES.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-01-10 Cont ID  
Sent By dpalmer Date 2001-01-10 Time 09:16 Rev Time 0.00
Received By dpalmer Date 2001-01-09 Time 20:00 Sent To  
Notes
2001-01-10 00:00:00***************** UNSAT ****************
  
 1)NOTE: AS ASKED FOR ON PREVIOUS REVIEW,
 PLEASE SHOW ALL BRANCH CIRCUIT#`S ON
 PLANS AND CORRELATE WITH PANEL
 SCHEDULES.
  
 2)NOTE: PLEASE SHOW THE AIC RATINGS OF
 EACH PIECE OF EQUIPMENT ON PLAN. FAULT
 CURRENT IS SHOWN BUT JUST NEEDS TO HAVE
 THE RATINGS SHOWN.
  
 3)NOTE: PLEASE LABEL ALL PANELS IE.
 "A","B", "C" ETC ETC
 ALSO PLEASE SEE PLANS, PLANS SHOW 6
 PANELS AND ONLY 3 PANEL SCHEDULES WERE
 SUBMITTED.? A,B,C SHOWN AND D,E,F IS
 NOT SHOWN. ????
  
 4)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS
 ATE 125%. (LIGHTING) IF LOADS ON PANEL
 SCHEDULE ARE AT 125% ALREADY THEN PLEASE
 INDICATE THIS.
  
 5)NOTE: PLEASE SHOW OR CLARIFY THE
 GROUNDING ELECTRODE CONDUCTOR, BLDG
 STEEL, COLD WATER. PER 250-50
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS PLEAS
 E CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-09-14 Cont ID  
Sent By dpalmer Date 2000-09-14 Time 12:02 Rev Time 0.00
Received By dpalmer Date 2000-09-14 Time 12:02 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE SUBMIT PLANS SHOWING ALL
 BRANCH CIRCUIT #`S AND CORRELATE WITH
 PANEL SCHEDULES
  
 2)NOTE: PLEASE SHOW DETAIL ON PANELS
 BEING INSTALLED.
  
 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL EQUIPMENT BEING INSTALLED.MAINS/
 PANELS/BREAKERS. 110-9 AND 215-5
  
 4)NOTE:PLEASE SEE BOTTOM OF PANEL/LOAD
 SCHEDULE SHOWN. YOU SHOW SERVICE TO BE
 FURNISHED AS 400AMP. IS THIS GOING TO BE
 BYTWO SEPARATE SERVICES?PLEASE SEE
 NEC FOR TWO SERVICES SERVING ONE SPACE.
  
 5)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS
 AT 125%. LIGHTING ETC.
  
 6)NOTE: PLEASE SHOW WIRE SIZES,BRKR SIZE
 -S ETC FOR PANEL SCHEDULES.
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 5 Status P Date 2001-11-14 Cont ID  
Sent By btrobaug Date 2002-10-30 Time 11:12 Rev Time 0.00
Received By mcarsill Date 2001-11-14 Time 09:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2001-02-13 Cont ID  
Sent By dpalmer Date 2001-11-05 Time 18:58 Rev Time 0.00
Received By mcarsill Date 2001-02-13 Time 11:31 Sent To  
Notes
2001-02-13 00:00:001) PROVIDE COMPLETE FIRE SPRINKLER
 AND FIRE ALARM DRAWINGS PRIOR TO
 STARTING TO INSTALLATION.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-02-05 Cont ID  
Sent By mcarsill Date 2001-02-05 Time 13:34 Rev Time 0.00
Received By mcarsill Date 2001-02-05 Time 13:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-12-28 Cont ID  
Sent By mcarsill Date 2000-12-28 Time 08:02 Rev Time 0.00
Received By mcarsill Date 2000-12-28 Time 08:02 Sent To  
Notes
2001-01-08 00:00:001) BUILDING ADDRESS NOT SHOWN ON
 ELEVATION DRAWINGS. BUILDING ADDRESS TO
 COMPLY WITH CITY CODE REQUIREMENTS.
 2) PLEASE INDICATE IN WRITING IF THE
 EXISTING FIREPLACE WILL BE USED OR IS
 ONLY FOR ORNAMENTAL LOOK.
 3) THE FIRE SPRINKLER SYSTEM
 INSTALLATION IS REQUIRED TO HAVE A
 SEPARATE PLAN AND PERMIT PRIOR TO
 INSTALLATION.
 4) THE FIRE ALARM SYSTEM DRAWING
 INDICATES OPTIONAL CENTRAL STATION
 MONITORING. CENTRAL STATION MONITORING
 IS REQUIRED BY BOTH BUILDING AND FIRE
 CODE REQUIREMENTS.
  
 NOTE: ON DECEMBER 29,2000, THIS WRITER
 ALONG WITH CHEIF BUILDING INSPECTOR
 LOU HATTEN WILL VISIT THE BUILDING TO
 EXAMINE EXISTING ISSUES RELATING TO THE
 BUILDING.
  
 APPROVED PROVISO:
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-08-23 Cont ID  
Sent By mcarsill Date 2000-08-23 Time 11:58 Rev Time 0.00
Received By mcarsill Date 2000-08-23 Time 11:57 Sent To  
Notes
2001-01-08 00:00:001) NO FIRE SPRINKLER DRAWINGS PROVIDED
 WITH PLANS. THE CODE RESEARCH BOX
 INDICATES FIRE SPRINKLERS ARE PRESENT
 IN THE CORRIDORS ONLY.
 2) NO FIRE ALARM SYSTEM SHOWN ON
 DRAWINGS. PLEASE BE ADVISED THAT SINCE
 THE BUILDING IS THREE STORIES HIGH, A
 FIRE ALARM SYSTEM IS REQUIRED. PLEASE
 NOTE THAT THE EXISTING FIRE SPRINKLER
 SYSTEM SHOULD BE SUPERVISED IN
 ACCORDANCE WITH BUILDING AND FIRE CODE
 REQUIREMENTS.
 3) ALL STORAGE, EQUIPMENT, AND
 MECHANICAL ROOMS IF NOT FIRE SPRINKLER
 PROTECTED TO BE AT LEAST ONE HOUR FIRE
 RATED WITH C LABELED FIRE DOORS WITH
 SELF-CLOSING DEVICES.
 4) PLEASE PROVIDE MORE INFORMATION ON
 SIX INCH STEP NEAR STAIR B.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2002-10-30 Cont ID  
Sent By btrobaug Date 2002-10-30 Time 11:12 Rev Time 0.00
Received By btrobaug Date 2002-10-29 Time 11:11 Sent To FIRE
Notes
2002-10-30 00:00:00TO FIRE IN BOX./WRT.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2001-11-05 Cont ID  
Sent By pkrauss Date 2001-11-05 Time 09:49 Rev Time 0.45
Received By pkrauss Date 2001-11-05 Time 09:49 Sent To  
Notes
2001-11-05 00:00:00NOTES ON MECH PERMIT 00090058

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-01-18 Cont ID  
Sent By ndenmark Date 2001-01-18 Time 10:48 Rev Time 0.50
Received By ndenmark Date 2001-01-18 Time 10:48 Sent To  
Notes
2001-01-18 00:00:00PROVISO:
 OUTSIDE AIR INTAKE FROMHEAT WHEEL
 TO BE MIN. 10 FT FROMEXHAUST OUTLET
 PER 1997 SMC 406 OR EXHAUST OUTLET
 SHALL BE MIN. TWO FT ABOVE AIR INTAKE.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-09-06 Cont ID  
Sent By ndenmark Date 2000-09-06 Time 09:16 Rev Time 1.00
Received By ndenmark Date 2000-09-06 Time 09:16 Sent To  
Notes
2001-01-08 00:00:00**************DENIED********************
 1. PROVIDE INFORMATION ON LOCATION AND
 OPERATION OF HEAT WHEEL
 2. PROVIDE INFORMATION ON CONDENSATE
 DRAIN INSTALLATION
 3. PROVIDE INFORMATION ON SEQUENCE OF
 OPERATION ESP. O/A DAMPER. DAMPER SHALL
 NOT REDUCE QUANTITY OF OUTSIDE AIR BELOW
 ASHRAE 62-89 REQUIRED VALUES DURING
 OCCUPIED TIMES
 4. FIRE DAMPERS NOT SHOWN AT ALL RATED
 WALL PENETRATIONS. 1997 SMC 610.6
 REQUIRES LOCATION AND INSTALLATION
 DETAILS ON THE BUILDING PLANS
 5.NO VENTILATION SHOWN FOR COMMON AREAS
 6. PROVIDE DETAILS ON SHAFTS SHOWING
 COMPLIANCE WITH 1997 SMC 610.4
 7. FAN SHUT DOWN BY DUCT SMOKE DETECTORS
 REQUIRED PER 1997 SMC 406.
 8. NOTE: CONDENSING UNITS ARE TO BE
 MOUNTED ON SOLID CONCRETE PADS MINIMUM
 3" ABOVE FINISHED GRADE. SERVICE ACCESS
 AND ELECTRICAL ACCESS TO COMPLY WITH SMC
 AND THE NATIONAL ELECTRIC CODE.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-01-30 Cont ID  
Sent By jleech Date 2001-01-30 Time 15:10 Rev Time 1.00
Received By pschmitz Date 2001-01-30 Time 15:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-01-08 Cont ID  
Sent By jleech Date 2001-01-08 Time 11:50 Rev Time 2.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED;
  
 1.NOTE 20. CONDENSATE OVER 3 TONS MUST
 GO TO DRYWELL OR STORM SMC 304.8.3.
  
 2.NOTE 25. CLEANOUTS MUST BE NOT MORE
 THAN 80' FOR FOUR INCH. PIPE SPC 710.1
  
 3.PLUMBING RISER DIAGRAM NOT TO CODE;
 A.MAIN VENT SHOULD COMPLY WITH SPC
 918.
 B.VENT STACK SHOULD TIE INTO WASTE
 STACK 6" ABOVE HIGHEST FIXTURE AS
 MAIN VENT.
 C.WHERE DOES WASTE GO FROM W/C AND
 LAV. LEFT SIDE OF DIAGRAM ALL
 THREE FLOORS?
  
 4.(WATER RISER) COLD WATER MAIN GOES
 FROM 1 1/2 TO 1 1/4 BACK TO 1 1/2
 PLEASE RE-SIZE.
  
 5.SHOW HOT WATER RISER FROM FIRST FLOOR
 TO THIRD FLOOR.
  
 6.AIR CHAMBERS TO COMPLY WITH SPC
 607.8.3.
  
 7.SHOW SIZE AND TYPE OF WATER HEATER.
  
 8.DRINKING FOUNTAINS SHALL COMPLY WITH
 FACBC 4.1.3(10) (A) 415. PROVIISIONS
 SHALL BE MADE FOR PEOPLE WHO HAVE
 TROUBE BENDING OR STOOPING.
  
 9.HANDICAP STALLS (MENS ROOM) ALL THREE
 FLOORS MUST BE 66" WIDE FOR CLEAR
 FLOOR SPACE 36" FOR W/C AND 30" FOR
 LAVITORYS.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-08-26 Cont ID  
Sent By tlarge Date 2000-08-26 Time 11:48 Rev Time 0.85
Received By pschmitz Date 2000-08-26 Time 11:25 Sent To  
Notes
2001-01-08 00:00:001)ACCESSIBLE TOILET ROOMS WITHIN THE
 RESTROOM SHALL COMPLY W/FACBC SEC.4.17.3
 MIN.WIDTH SHALL BE 83"IF LAV.IS ADJACENT
 TO W.C.IF YOU DISAGREE CALL THE DEPT.OF
 COMMUNITY AFFAIRS AT 850-487-1824 FOR
 AN INTERPRETATION.
  
 2)BREAK ROOM COUNTERS AND SINK SHALL
 COMPLY W/FACBC SEC.4.24.1-4.24.7.
  
 3)DRINKING FOUNTAINS ARE REQD.ON EACH
 FLOOR PER TABLE 407 OF SPC.FOUNTAINS
 SHALL COMPLY W/FACBC SECS.4.1.3.(10)(A).
 4.15.PROVISIONS SHALL BE MADE FOR PEOPLE
 WHO HAVE TROUBLE BENDING OR STOOPING.
  
 4)FLOOR DRAINS ARE REQD.IN THE TOILET
 ROOMS PER SPC SEC.409.4.1.1.DRAINS SHALL
 BE EQUIPPED W/TRAP PRIMERS.
  
 5)ALL EXPOSED PIPES AND SURFACES SHALL
 BE INSULATED PER FACBC SEC.4.19.4.(SEE
 SHT.A5).
  
 6)SHT.A5-FIXTURE COUNT SHALL BE BASED ON
 THE 1994 STANDARD PLUMBING CODE,NOT 1997
  
 7)SUBMIT A WATER ISOMETRIC FOR REVIEW
 THAT COMPLIES W/SPC 1994 EDITION IN ALL
 RESPECTS.
  
 8)SUBMIT A NEW SANITARY ISOMETRIC FOR
 REVIEW.THE ONE SUBMITTED HAS FAR TOO
 MANY VIOLATIONS TO LIST.COMPLY W/SPC.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop Z ZONING
Rev No 2 Status P Date 2001-02-16 Cont ID  
Sent By jwitmer Date 2001-02-16 Time 09:04 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-02-16 00:00:00PASSED PER A.G.

Review Stop Z ZONING
Rev No 1 Status F Date 2000-10-02 Cont ID  
Sent By lmartine Date 2000-10-02 Time 11:10 Rev Time 0.00
Received By lmartine Date 2000-09-27 Time 11:23 Sent To  
Notes
2001-01-08 00:00:00NOTES PER MINICOZZI
  
 PLEASE SCREEN MECHANICAL EQUIPMENT PER
 ZONING CODE