Plan Review Details - Permit 00080964
| Plan Review Stops For Permit 00080964 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-11-06 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-11-06 |
Time |
08:39 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-09-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-09-18 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-03 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-03 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-23 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-23 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | REVISE PLANS FOR CIRCUIT #`S AND PANEL | | | SCHEDULE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-11-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-02 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-02 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-18 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-08-18 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) INTERIOR FINISHES ON NEW WALLS SHALL | | | BE CLASS A, B, OR C. | | | 2) EMERGENCY LIGHTS AND EXIT SIGNS NOT | | | SHOWN ON DRAWINGS. PLEASE ENSURE THAT | | | IF NOT ALREADY EXISTING THAT THEY | | | BE INSTALLED AT EXIT LOCATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-08-24 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-24 |
Time |
15:15 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-08-24 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO MECH PLANS PROVIDE W/ MECH PERMIT APP | | | PRIOR TO ANY MECH WORK COMMENCING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-09-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-29 |
Time |
15:54 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-09-29 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | TOILET ROOM SHALL COMPLY W/FACBC FIG.28. | | | | | | 2)SINK IN TOILET ROOM SHALL COMPLY W/ | | | FACBC SEC.4.24.1-4.24.7. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-21 |
Time |
17:54 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-08-21 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)INDICATE IF TOILET ROOMS ARE NEW OR | | | EXISTING.IF NEW SHOW DIMENSIONS OF | | | TOILET ROOMS. | | | | | | 2)SINK SHALL COMPLY W/FACBC SECS.4.24.1- | | | THRU 4.24.7. | | | | | | 3)SUBMIT WATER AND SANITARY RISER FOR | | | ALL NEW WORK. |
|
|
|