| Plan Review Stops For Permit 00080936 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2001-04-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-20 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-20 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2001-04-20 00:00:00 | PLANS ARE TO BE RE-DRAWN BEFORE FINAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-04-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-05 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-05 |
Time |
18:52 |
Sent To |
|
|
| Notes |
| 2001-04-05 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT THE ORIGINAL | | | PLAN WAS SUBMITTED AGAIN WITH | | | HANDWRITTEN CHANGES W/OUT ENGINEER OF | | | RECORD SIGING EACH CHANGE. ALSO, THE | | | COPY OF PLAN IS VERY UNCLEAR. PLEASE | | | NOTE UNDER F.S. | | | F.A.C, COUNTY AND CITYWIDE | | | ADMINISTRATIVE CODE. 104.2, 104.2.1, | | | 471.025 PLANS ARE TO BE CLEAR AND | | | LEGIABLE.PLEASE HAVE ELECTRICAL PART | | | OF PLAN RE-DRAWN . | | | | | | | | | 2)NOTE: PLEASE NOTE THERE ARE NOT ENOUGH | | | CONDUCTORS SHOWN COMING FROM MAIN PANEL | | | AT HOUSE. PLANS SHOW 2-6`S AND 1-#8. | | | WHERE IS NEUTRAL? OR IS #8 NEUTRAL? IF | | | SO THEN WHERE IS EQUIPMENT GROUNDING | | | CONDUCTOR? | | | | | | 3)NOTE: PLEASE NOTE MISSING OUTLET FOR | | | BATH. 210-52D ,#12, 20A. | | | | | | 4)NOTE: PLEASE NOTE THAT PLANS SHOW THAT | | | THERE IS NO ADDED LOAD ? HOW IS THIS | | | POSSIBLE? | | | | | | AS ON PREVIOUS NOTES, PLEASE CALL IF THE | | | RE ARE ANY QUESTIONS, OR CLARIFICATION | | | NEEDED. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2001-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-20 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-20 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2001-03-20 00:00:00 | ******************* UNSAT ************* | | | | | | 1)NOTE: PLEASENOTE THAT PER F.A.C. | | | ALL PLANS THAT ARE SIGNED AND SEALED BY | | | AN ARCH/ENGINEER NEED TO HAVE ALL | | | CHANGES DONE BY THAT PERSONOF RECORD. | | | | | | 2)NOTE: PLEASE NOTE PLANS ARE TO BE RE- | | | DONE TO MEET ALL ORIGINAL NOTES. | | | | | | 3)NOTE: PLEASE NOTE THAT TWO COPIES ARE | | | TO BE SUBMITTED FOR REVIEW. ONE COMES | | | BACK FOR YOUR RECORD ON THE JOB AND THE | | | OTHER IS FOR OUR RECORD. | | | | | | 4)NOTE: PLEASE CLARIFY PLANS SHOWING | | | 3-2/0`S GOING TO A 60A MAIN. PLEASE | | | CLARIFY HOW 2/0 WIRE IS GOING TO FIT | | | INTO A 60A MAIN.?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-16 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-16 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************* REVISION REQUESTED ******* | | | | | | 1)NOTE: PLEASE PROVIDE CLARIFICATION ON | | | PANEL FOR GARAGE. MAIN BRKR? A MAIN | | | MEANS OF DISCONNECT IS REQ`D. | | | | | | 2)NOTE: PLEASE SHOW GROUNDING PER NEC | | | FOR DETACHED GARAGE. COLD WATER,GRND ROD | | | | | | 3)NOTE: PLEASE SEE REQ`MENTS FOR SD`S | | | INSIDE SLEEPING ROOMS! NFPA-72 2-2.1.1.1 | | | | | | 4)NOTE: PLEASE PROVIDE A GFI REC OUTSIDE | | | PER 210-52E | | | | | | THE FOLLOWING ARE NOTES TO QUESTION | | | ANY OTHER ISSUES THAT MAY ARISE. | | | IS THERE GOING TO BE CATV OR TELEPHONE | | | OUTLETS INSTALLED?? | | | WHERE IS THE HOT WATER COMING FROM? | | | PLEASE CLARIFY! | | | IS THERE GOING TO BE CENTRAL A/C OR IS | | | THERE GOING TO BE A WINDOW UNIT? | | | PLEASE PROVIDE CLARIFICATION ON THE | | | ABOVE INFORMATION. | | | | | | ALSO PLEASE NOTE THAT PROVISIONS FOR | | | KITCHEN COOKING EQUIPMENT WILL NOT BE | | | PERMITTED TO BE INSTALLED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE ANY ROUGH ELECTRICAL | | | INSPECTION IS CALLED IN. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-23 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-23 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ********* UNSAT ********************** | | | | | | NO ELECTRICAL PLANS SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-08-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-08-26 |
Time |
08:53 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-08-26 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-16 |
Time |
18:56 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-16 |
Time |
18:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-26 |
Time |
05:30 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-08-26 |
Time |
05:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SUBMIT SANITARY AND WATER ISOMETRICS | | | FOR REVIEW.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.104.2.1.COMPLY W/SPC. | | | | | | 2)SHOWER SHALL BE A MIN.OF 30"WIDE AND | | | MIN.1024 SQ.IN.TOTAL AREA.COUNTYWIDE | | | AMENDMENTS TO SPC SEC.409.8. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-12-04 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-12-04 |
Time |
10:36 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-12-04 |
Time |
10:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-09-18 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-09-18 |
Time |
14:09 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-09-18 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | *************BUILDING UNSAT************* | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 COPIES OF PRODUCT APPROVALS | | | THAT ARE SUPPLIED. | | | | | | 2)PROVIDE STORM PANEL INFORMATION | | | COMPLETE WITH INSTALLATION SCHEDULE AND | | | KEY PLAN WITH SPECIFIC ANCHORS TO BE USE | | | | | | 3)PROVIDE WALL SECTION DETAILS, DETAILS | | | TO BE COMPLETE WITH ALL CONNECTORS AND | | | MATERIALS TO BE USED. | | | | | | 4)PROVIDE DETAILS OF SLAB REPAIR AND | | | JOIST REPAIR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-08-22 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-08-22 |
Time |
10:07 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|