| Plan Review Stops For Permit 00080930 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-09-20 |
Time |
13:29 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-09-20 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-09-14 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-09-14 |
Time |
08:04 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-09-14 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.SHEET A5, DETAIL C, HAVE STRUCTURAL | | | ENGINEER CERTIFY LOADING OF BOTTOM | | | CORD OF ROOF TRUSSES WITH WOOD BEAM | | | AND CEILING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-09-05 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-09-05 |
Time |
10:37 |
Rev Time |
1.20 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | A. SHEET CS1 | | | 1. CODE REFERENCES, CORRECT THE | | | FOLLOWINF, | | | MECHANICIAL CODE IS 1997 NOT 1994 | | | BUILDING CODE IS 1997 NOT 1999 | | | ELECTRICAL CODE IS 1999 NOT 1996 | | | | | | B. SHEET CS2 | | | 1. NOTE #7 REFERS TO WRONG ACCESSABILITY | | | CODE PROPER REFERENCE IS TO FLORIDA | | | ACCESSABILITY CODE 1997 EDITION | | | | | | C. SHEET A1 | | | 1. SIGNS ARE NOT COVERED BY PRIME PERMIT | | | SUBMIT SEPERATE APPLICATION FOR PERMIT. | | | | | | D. SHEET A3 NOTES INDICATE EXTERIOR STUD | | | 1. NOTES INDICATE EXTERIOR STUD WALLS | | | THIS BUILDING IS IN THE FIRE DISTRICT | | | USE OF WOOD IS A VIOLATION OF 1997 SBC | | | SECTION F102.1, REVISE. | | | 2. NOTE ON STRUCTURAL, ALL STRUCTURAL | | | VERIFICATION IS TO BE PERFORMED BY A | | | FLORIDA LICENSED ENGINEER OR ARCHITECT. | | | | | | E. SHEET A5 | | | 1. DETAIL C, HAVE STRUCTURAL ENGINEER | | | CERTIFY LOADING OF BOTTOM CORD OF ROOF | | | TRUSSES WITH WOOD BEAM AND CELING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-25 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-25 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-09-20 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-09-20 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) PROVIDE PLANS AND PERMIT FOR FIRE | | | SPRINKLER REMODEL. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-08-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-18 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-08-18 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO BUILDING ADDRESS SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS TO | | | COMPLY WITH CITY CODE REQUIREMENTS. | | | 2) ENTRY DOORS MUST SWING IN THE | | | DIRECTION OF EXIT TRAVEL. | | | 3) OCCUPANT LOAD TO BE DETERMINED BY | | | THIS OFFICE. | | | 4) ALL EXIT DOORS SUBJECT TO AN | | | OCCUPANCY OF 100 OR MORE PERSONS ARE | | | TO BE EQUIPPED WITH APPROVED PANIC | | | HARDWARE. NO OTHER LOCKS WILL BE | | | PERMITTED. | | | 5) INTERIOR FINISHES SHALL BE CLASS | | | A OR B IN EXITS. INTERIOR FINISHES IN | | | OTHER AREAS SHALL BE CLASS A,B,OR C. | | | 6) PROVIDE COMPLETE PLANS FOR THE | | | INSTALLATION OF THE HOOD, DUCT, AND | | | EXTINGUISHING SYSTEM. A SEPARATE PERMIT | | | IS REQUIRED. | | | 7) GAS INSTALLATION TO COMPLY WITH | | | NFPA 54. | | | 8) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | 9) NO FIRE SPRINKLER DRAWINGS SUBMITTED | | | WITH PLANS. ACCORDING TO FIRE RESCUE | | | RECORDS, THIS BUILDING HAS AN EXISTING | | | FIRE SPRINKLER SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-10-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-10-06 |
Time |
08:00 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-10-06 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | 1. PROVIDE CFM VALUES AND ALL DUCT SIZES | | | 2. PROVIDE INFORMATION ON EQUIPMENT SCHE | | | DULE INCLUDING SEER AND OUTSIDE AIR | | | 3. FAN SHUT DOWN BY DUCT SMOKE DETECTOR | | | REQUIRED WITH NOTIFICATION BY BLDG ALARM | | | OR HORN AND STROBE PER NFPA 90A 4.4-4. | | | | | | INFORMATION TO BE SUBMITTED PRIOR TO | | | FINAL INSPECTION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-08-28 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-28 |
Time |
09:14 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-08-28 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | 1.FAN SHUT DOWN BY DUCT SMOKE DETECTOR | | | TO BE TESTED | | | 2.SEPARATE PERMITS REQUIRED FOR HOODS, | | | COOLERS, SUPPRESSION SYSTEMS. SUBMIT | | | PLANS AT TIME OF PERMIT APPLICATION FOR | | | THESE SYSTEMS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-20 |
Time |
10:50 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-09-20 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEPARATE PLANS AND PERMIT REQD.FOR GAS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-09-19 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-19 |
Time |
15:05 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-09-19 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)PLANS SHALL BE APPROVED BY THE DEPT.OF | | | BUSINESS REG.PRIOR TO REVIEW BY THIS | | | DEPT.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 101.4.7. | | | | | | 2)INDICATE TYPE OF GAS PIPING USED IN | | | THE GAS SYSTEM.COMPLY W/SGC SEC.305.4. | | | | | | 3)VOID/DELETE ALL OLD SHEETS . | | | | | | 4)COMPLY W/ALL PREVIOUS COMMENTS FOR GAS | | | SYSTEM. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. | | | 561-659-8096,EXT.8377. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-09-13 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-13 |
Time |
15:09 |
Rev Time |
2.50 |
| Received By |
tlarge |
Date |
2000-09-13 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SUBMIT OCCUPANT LOAD BASED ON SQ.FT.OF | | | HABITABLE FLOOR SPACE PER SPC TABLE 407. | | | SEE SPC.SEC.407.1.3 FOR ALLOWED | | | DEDUCTIBLE AREAS. | | | | | | 2)DESIGN OF GREASE TRAP SHALL COMPLY W/ | | | CITY OF WPB BUILDING DEPT.REQS.(SEE | | | ATTACHED).CONTACT ROD COMPO AT | | | (561)835-7423 FOR APPROVAL OF SIZE. | | | SUBMIT APPROVAL FORM FROM UTILITIES DEPT | | | COUNTYWIDE AMENDMENTS TO SPC SEC.101.4.7 | | | | | | 3)SUBMIT A COMPLETE GAS RISER DIAGRAM | | | FOR REVIEW.SHOW ALL EQUIPMENT ON THE GAS | | | RISER DIAGRAM.COMPLY W/ATTACHED GAS REQS | | | | | | 4)VACUUM RELIEF VALVE ON WATER HEATER | | | IS NOT PROPERLY CONNECTED.INSTALLATION | | | SUBJECT TO FIELD INSPECTOR'S APPROVAL. | | | SPC SEC.507.1.2. | | | | | | 5)PLANS SHALL BE ROUTED TO DEPT.OF | | | BUSINESS REGULATION FOR REVIEW AND | | | APPROVAL PRIOR TO APPROVAL BY THIS DEPT. | | | CALL (954)958-5520.COUNTYWIDE AMENDMENTS | | | TO SPC SEC.101.4.7. | | | | | | 6)SHT.K-2 LISTS CONNECTION OF GAS EQUIP. | | | W/GAS HOSE.GAS HOSE IS PROHIBITED PER | | | SGC SEC.403.2.COMPLY W/SGC SEC.403.1.1. | | | | | | 7)RELIEF DRAIN FOR EWH SHALL DISCHARGE | | | INTO A FLOOR SINK,NOT A FLOOR DRAIN PER | | | SPC SEC.804.1.,807.1.3. | | | | | | 8)IF YOUR OCCUPANT LOAD REMAINS AT 120 | | | PERSONS ADDITIONAL PLUMBING FIXTURES | | | WILL BE REQD.PER SPC TABLE 407. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-26 |
Time |
10:04 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-08-26 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)HANDICAP STALLS SHALL COMPLY W/FACBC | | | SEC.4.17.3.(MIN.WIDTH SHALL BE 83"IF | | | LAV.IS ADJACENT TO W.C.)SEE 4.1.6.(B) | | | | | | 2)SUBMIT OCCUPANT LOAD BASED ON SQ.FT.OF | | | HABITABLE FLOOR SPACE PER SPC TABLE 407. | | | SEE SPC SEC.407.1.3.FOR ALLOWED | | | DEDUCTIBLE AREAS. | | | | | | 3)DISHWASHER AND GARBAGE DISPOSAL SHALL | | | BYPASS GREASY WASTE AND CONNECT TO | | | SANITARY SYSTEM PERCITY ORDINANCE. | | | | | | 4)DESIGN OF GREASE TRAP SHALL COMPLY W/ | | | BUILDING DEPT.REQS. (SEE ATTACHED) | | | CONTACT ROD COMPO AT 561-835-7423 FOR | | | APPROVAL OF SIZE.SUBMIT APPROVAL FORM | | | FROM UTILITIES. | | | | | | 5)SHOW ALL EQUIPMENT ON GAS DRAWING.SEE | | | ATTACHED FOR REQS. | | | | | | 6)SHUT-OFF VALVE,AUTOMATIC GAS VALVE( | | | FIRE VALVE)AND UNION SHALL BE INSTALLED | | | BELOW CEILING AND BE ACCESSIBLE.NFPA | | | 5.5.4. | | | | | | 7)GREASY WASTE DESIGN SHALL COMPLY W/ | | | SPC SEC.921. | | | | | | 8)SHT.P-1-BOTTOM FED WATER HEATER SHALL | | | BE EQUIPPED W/VACUUM RELIEF VALVE PER | | | SPC SEC.507.1.2. | | | | | | 9)SHT.P-4-WATER CLOSETS AND FIXTURE | | | BRANCHES NOT PERMITED ON WET VENTS PER | | | COUNTYWIDE AMENDMENTS TO SPC SEC.911.1.1 | | | | | | 10)HUB DRAINS NOT PERMITTED.REVISE TO | | | FLOOR DRAIN. | | | | | | 11)SHT.P-4-FLAT DRY VENT NOT PERMITTED | | | FOR CAN WASH. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|