Plan Review Details - Permit 00080910
Plan Review Stops For Permit 00080910
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-11-27 Cont ID  
Sent By dpalmer Date 2000-11-27 Time 19:37 Rev Time 0.00
Received By dpalmer Date 2000-11-27 Time 19:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-11-16 Cont ID  
Sent By dpalmer Date 2000-11-16 Time 19:50 Rev Time 0.00
Received By dpalmer Date 2000-11-16 Time 19:50 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE SEE F.A.C ONLY THE ARCH/
 ENGINEER OF RECORD CAN MAKE CHANGES TO
 SIGNED AND SEALED PLANS. THIS IS STATE
 LAW AND VIOLATES 61G16 AND 481 OF
 F.A.C
  
 ALSO PLEASE NOTE THAT THE COPIES OF THE
 NATIONAL ELECTRIC CODE THAT WERE SUB-
 -MITTED FOR MY REVIEW WERE OUT OF THE
 "96" NEC. WE ARE IN THE "99" NEC AND
 HAVE BEEN SINCE MARCH 1ST OF 2000.
 PLEASE SEE ALL THE CODE ARTS IN THE"99"
 FOR MY REFERENCES.
  
 PLEASE SUBMIT PLANS WITH ALL THE ABOVE
 INFORMATION CORRECTED AND DONE BY THE
 ARCH. OF RECORD. SIGNED, SEALED AND
 DATED PER F.A.C. 481.221.
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 659-8096 EXT 8372
  
  
 ALSO PLEASE NOTE THAT PLANS ARE STAMPED
 BY ARCH. THIS IS UNACCEPTABLE PER FS.
 WET SIGNATURE,RAISED SEALED AND DATED!!
 481.221

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-09-13 Cont ID  
Sent By dpalmer Date 2000-09-13 Time 19:25 Rev Time 0.00
Received By dpalmer Date 2000-09-13 Time 19:25 Sent To  
Notes
2001-01-08 00:00:00****************** UNSAT ***************
  
 1)NOTE: PLEASE SEE 210-8-A-6 FOR OUTLETS
 SERVING KITCHEN COUNTERSPACE.
  
 2)NOTE: PLEASE SEE NFPA-72 2-2.1.1.1.
 FOR SMOKE DETECTORS INSIDE AND OUTSIDE
 BEDROOMS AND IN BEDROOM #3 NOW THAT
 WORK IS BEING DONE IN THERE.
  
 3)NOTE: PLEASE SEE 215-5 FOR ALL THE
 INFORMATION REQ`D ON LOAD CALCULATIONS/
 RISER DIAGRAM ETC.
  
 4)NOTE: PLEASE SEE 230-72 FOR GROUPING
 OF MAINS. MAINS TO BE GROUPED.
  
 5)NOTE: PLEASE SEE THAT YOU SHOW ON
 RISER DIAGRAM PANEL BEING EXISTING AND
 NEW.???? PLEASE CLARIFY.
  
 6)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED. PER
 110-9 AND 215-5.
  
 7)NOTE:PLEASE SEE 210-11-C-3 FOR THE
 REQ`D BATH(S) CIRCUIT(S) TO BE LISTED ON
 PANEL SCHEULE.
  
 8)NOTE: PLEASE SEE PIPE FILL FOR 1 1/4
 SCHED 80 PVC. SEE ALL THE WIRE BEING
 SHOWN.
  
 9)NOTE: PLEASE SEE 250-50 FOR GROUNDING
 ELECTRODE SYSTEM. PLEASE SHOW AND INCL-
 -UDE BLDG.STEEL AND COLD WATER PIPE.
  
 10)NOTE: PLEASE SHOW LOCATION OF NEW
 PANEL BEING INSTALLED FOR THE ADDITION.
  
 11)NOTE: PLEASE SEE 110-26 FOR CLEARENCE
 REQ`MENTS IN CLOSET IN MASTER/ALCOVE
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. PLEASE NOTE THAT IF THERE
 ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-11-28 Cont ID  
Sent By jleech Date 2000-11-28 Time 16:29 Rev Time 0.25
Received By jleech Date 2000-11-28 Time 16:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2000-11-15 Cont ID  
Sent By jleech Date 2000-11-15 Time 17:28 Rev Time 0.33
Received By jleech Date 2000-11-15 Time 17:27 Sent To  
Notes
2001-01-08 00:00:00DENIED;
 1.SIZE ALL DUCT ROUND AND DUCTBOARD.
 2.SHOW CFM'S FOR EACH DROP.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-08-30 Cont ID  
Sent By jleech Date 2000-08-30 Time 16:41 Rev Time 0.33
Received By jleech Date 2000-08-30 Time 16:40 Sent To  
Notes
2001-01-08 00:00:00DENIED
 1.SIZE ALL DUCTS ROUND AND DUCTBOARD.
 2.SHOW CFM'S FOR EACH DROP.
 3.EXHAUST FAN REQUIRED IN TUB AREA ALSO
 BOTH FANS TO VENT TO OUTSIDE.
 4.SHOW C/U LOCATION.
 5.FREON LINES UNDER SLAB OR OVERHEAD?

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-11-28 Cont ID  
Sent By jleech Date 2000-11-28 Time 16:29 Rev Time 0.25
Received By jleech Date 2000-11-28 Time 16:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-09-05 Cont ID  
Sent By tlarge Date 2000-09-05 Time 06:54 Rev Time 0.30
Received By tlarge Date 2000-09-05 Time 06:42 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-11-29 Cont ID  
Sent By rmcdouga Date 2000-11-29 Time 12:26 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 WINDOWS AND DOORS PRIOR TO INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-11-17 Cont ID  
Sent By rmcdouga Date 2000-11-17 Time 12:04 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
 RESUB
  
 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR ROOF
 COVERING MATERIAL, EXTERIOR DOORS AND
 WINDOWS THAT WILL BE INSTALLED ON NEW
 ADDITION.
  
 2)PROVIDE PRODUCT APPROVALS, KEY PLAN
 AND INSTALLATION SCHEDULE WITH TYPE OF
 ANCHORS BEING USED OR APPLY UNDER A
 SEPARATE PERMIT.
  
 3)HAVE OWNER OR THEIR AGENT (CONTRACTOR)
 SIGN THE ENERGY FORMS.
  
 4)HAVE THE ARCHITECT HAND SIGN EACH PAGE
 OF THE PLANS.
  
 5)PROVIDE SAFETY GLASS IN BATHROOM
 WINDOWS.97SBC 2405.2
  
 6)HAVE ARCHITECT CORRECT CHECK HELTA 20
 ON SHEET S-1.
  
 7)HAVE DESIGNER OF RECORD PROVIDE
 ADDITIONAL INFORMATION DETAILING THE
 CONNECTION OF THE NEW ADDITION TO THE
 EXISTING STRUCTURE AT FOOTINGS, WALL
 AND TIE BEAM.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-09-27 Cont ID  
Sent By rmcdouga Date 2000-09-27 Time 07:50 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 WINDOWS THAT WILL BE INSTALLED.
  
 2)PROVIDE PRODUCT APPROVALS FOR ROOFING
 MATERIALS.
  
 3)PROVIDE NEGATIVE AND POSITIVE DESIGN
 PRESSURES FOR ADDITION WINDOWS.
  
 4)PROVIDE PRODUCT APPROVALS,KEY PLAN AND
 INSTALLATION SCHEDULE FOR STORM PANELS
 OR PRODUCT APPROVALS FOR IMPACT
 RESISTANT WINDOWS. IMPACT PROTECTION IS
 REQUIRED FOR ALL EXTERIOR GLAZED
 OPENINGS.CITY AMENDMENTS SEC.1606.4
  
 5)PROVIDE ENERGY CODE CALCULATIONS
 INCLUDING MANUAL "J" PER 97 FL ENERGY
 EFFICIENCY CODE.
  
 6)WET SIGNATURE OF ARCHITECT IS REQUIRED
 ON DRAWINGS. SIGNATURE STAMP IS NOT
 ACCEPTABLE.
  
 7)SAFETY GLASS IS REQUIRED IN BATHROOM
 PER 97SBC SEC 2405.2.
  
 8)PLEASE INDICATE THE LENGTH OF 5/8"
 ANCHOR BOLTS @ 24"O.C. ON SHEET S-1.
  
 9)SHEET S-1 SHOWS HELTA 20 TRUSS ANCHORS
 SHOULD THESE BE HETAL 20? PLEASE RECHECK
  
 10)PLEASE PROVIDE CONNECTION DETAILS OF
 ADDITION TO EXISTING STRUCTURE FOR WALLS
 FOOTINGS,AND TIE BEAMS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-08-22 Cont ID  
Sent By gjoyce Date 2000-08-22 Time 10:01 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***