| Plan Review Stops For Permit 00080584 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2001-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-08-24 |
Time |
08:48 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2001-08-24 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2001-08-24 00:00:00 | REVISION #2/3 8/24/01JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-06-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-06-04 |
Time |
14:12 |
Rev Time |
1.25 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-04 00:00:00 | REVISION # 1 MAY 30/01 JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-08 |
Time |
13:35 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2001-02-08 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2001-02-08 00:00:00 | PROVISO: | | | 1)- THE 2ND FLOOR WILL BE USED FOR | | | "STORAGE" TAKING EXCEPTION TO #2 FOR | | | STORAGE UNDER FL SS 553.509, CHANGE OF | | | OCCUPANCY WILL REQUIRE VERTICAL ACCESS- | | | IBILTY. | | | 2)- SBC 709.5.2.2 STRUCTURAL STEEL | | | BEAMS & GIRDERS REQUIRE FIRE RESISTANT | | | MATERIALS, PROVIDE PRODUCT INFORMATION. | | | 3)- PAY COUNTY IMPACT FEES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-01-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-01-19 |
Time |
15:13 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-19 00:00:00 | BUILDING PLAN REVIEW: | | | 1)- SBC 104.2.2- ADDITIONAL INFO | | | SHEET A-1 SHOWS A STAIRWAY AT THE BACK | | | OF THE EXISTING BUILDING ON THE SECOND | | | FLOOR PLAN, IS THIS STAIR BEING DELETED? | | | IF NOT IT BLOCKS THE EGRESS ON THE | | | EGRESS ON THE FIRST FLOOR CORRIDOR. THE | | | SAME STAIRWAY SHOWS UP ON VARIOUS PLANS. | | | 2)- SHEET A-3 SECTION "CC" SHOWS AN | | | ADJACACEENT 2 STORY EXISTING WALL. THE | | | DETAIL CALLS OUT FOR FOR UL DES U473 TO | | | BE INSTALLED ATOP OF A STEEL BEAM. HOW | | | WILL THE CEMENTITIOUS BACKER BOARD BE AT | | | TACHED? THE SECOND QUESTION IS HOW WILL | | | THE BOTTOM OF THE CEMENTITIOUS BOARD BE | | | SEALED FOR FIRE PROOFING? THE THIRD ITEM | | | IN THIS DETAIL IS A NOTE ON INSTALLING | | | FIRE MASTER BOARD UL 723 IN THE UL LIST- | | | ING BOOK X723 LIST A SPRAY TYPE OF INSUL | | | ATION, WE NEED MORE INFORMATION FOR THIS | | | 2 HR RATING? | | | 3)- SHEET RA-6 SHOWS A DETAIL ON THE | | | 1-HR RATED ACOUSTIC TILE CEILING, PLEASE | | | PROVIDE INFORMATION ON THE TILE, FRAME | | | AND TILE LOCKING OR HOLD DOWN. | | | 4)- NOTE: THE PLANS INDICATE THAT THE | | | SECOND FLOOR WILL BE USED FOR STORAGE | | | PURPOSES ONLY, TAKING THE EXCEPTION OF | | | NO ELEVATOR REQUIRED BY THE FL. ACCESS- | | | IBILITY CODE. IF THE TENANT OCCUPANCY | | | USAGE CHANGES TO A HABITABLE SPACE A | | | ELEVATOR WOULD BE REQUIRED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-11-07 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-07 |
Time |
08:43 |
Rev Time |
3.00 |
| Received By |
drunnels |
Date |
2000-11-06 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.SUBMIT DETAILS SHOWING ELECTRICAL | | | ROOM COMPLYING TO SECTION 1006&1007 | | | SBC 1997 EDITION | | | 2.SUBMIT DETAILS SHOWING STAIR TO WORK/ | | | LOFT COMPLYING TO SECTION 1007 1997 SBC | | | 3.SUBMIT DRAWING SHOWING BUILDING | | | COMPLYING TO THE 1997 FLORIDA | | | ACCESSIBILITY CODE FOR BUILDING | | | CONSTRUCTION. | | | 4.SUBMIT UL LISTING OF 1-HR RATED | | | DEMISING PARITION. | | | 5.SUBMIT DRAWING SHOWING ARRANGEMENT AND | | | NUMBER OF EXITS TO COMPLY WITH SECTION | | | 1004 1997 SBC | | | 6.SUBMIT PRODUCT APPROVALS FOR WINDOWS, | | | DOORS AND ROOF COVERINGS/METRO DADE CO./ | | | OR SBCCI. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2001-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-12 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-12 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2001-02-12 00:00:00 | 02/12/01 ARCH LETTER ELEC TO BE REVIEWED | | | UNDER A SEPERATE PLANS, PERMIT & FEES. | | | J. WITMER | | | LETTER FROM ARCH. ELEC PERMIT TO BE | | | ISSUED UNDER A SEPERATE PLANS, PERMIT | | | & FEES. J. WITMER | | | ELETRICAL PULLED FROM PLANS BY ARCH OF | | | RECORD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2001-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-22 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-22 |
Time |
19:11 |
Sent To |
|
|
| Notes |
| 2001-01-22 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRNET PER 110-9. | | | THIS INFORMATION WAS GIVEN ON SHEET E-4 | | | ON LAST SUBMITTAL BUT IS NOT SHOWN ON | | | SHEET RE-4A ON THIS SUBMITTAL. PLEASE DO | | | SO. | | | | | | 2)NOTE: PLEASE NOTE THAT UNDER F.A.C, | | | SEC 481-.221 ALL HAND WRITTEN CHANGES ON | | | PLANS ARE TO BE SIGNED AND DATED BY | | | THEARCH/OF RECORD. PLEASE SEE E- SHEETS | | | WITH BRANCH CIRCUIT #`S HAND WRITTEN | | | IN. PLEASE REDRAW PLANS BEFORE | | | RE-SUBMITTAL | | | PER COUNTY-WIDE ADMINISTRATIVE CODE SEC | | | 104.2.1 AND 104.2.7 | | | | | | 3)NOTE: PLEASE TRANSFER ATTACHED SHEETS | | | CONTAINING LOAD CALCULATIONS AND PANEL | | | SCHEDULES OF PANELS "A" AND "B". PLEASE | | | HAVE THESE DRAWN ON PLANS AS ATTACHED | | | SHEETS SEEM TO GET TORN OFF DURING | | | CONSTRUCTION. IF THOSE ATTACHED SHEETS | | | ARE PREPARED BY SOMEONE ELSE THEN UNDER | | | C.A.C THEY ARE TO BE SIGNED ALSO. SEC | | | 104.2.1. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-80096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2001-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-02 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-02 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE PROVIDE BRANCH CIRCUIT | | | #`S ON PLANS AND CORRELATE WITH PANEL | | | SCHEDULES. | | | | | | 2)NOTE:PLEASE SEE RISER THIS SHOWS PANEL | | | "A" FEEDING PANEL "B" YET PANEL SCHEDULE | | | -S SHOW MDP FEEDING PANELS A&B ??? | | | PLEASE CLARIFY. | | | PLEASE SEE THAT YOU SHOW A 100A MAIN ON | | | RISER FUSED AT 100AMPS? YET YOU SHOW A | | | PANEL SCHEDULE?? PLEASE CLARIFY. | | | | | | 3)NOTE; PLEASE SEE PLAN PANEL"A" | | | DOESN'T SHOW FEEDING PANEL "B". | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-22 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2001-08-22 00:00:00 | 1) PLEASE BE ADVISED THAT THIS LOCATION | | | IS LOCATED WITHIN THE CITY FIRE LIMITS. | | | CERTAIN RESTRICTIONS APPLY. | | | 2) BALCONY GUARDS AND HANDRAIL TO | | | COMPLY WITH THE REQUIREMENTS OF NFPA | | | 101, THE LIFE SAFETY CODE, 1985 EDITION. | | | A) GUARDS MUST BE AT LEAST 42" HIGH | | | B) MUST RESIST A 4" SPHERE SINCE THE | | | STANDARD BUILDING CODE, 1997 EDITION IS | | | MORE RESTRICTIVE THAN THE 1985 EDITION | | | OF THE LIFE SAFETY CODE. | | | C) MUST BE CONSTRUCTED FOR PRESCRIPTIVE | | | REQUIREMENTS OF HORIZONTAL LOADS. | | | 3) HANDRAILS REQUIRED ON BOTH SIDES OF | | | STAIR. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-02-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-08 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-08 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-01-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-01-30 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-01-30 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2001-01-30 00:00:00 | 1) BUILDING ADDRESS REQUIRED ON BUILDING | | | IN ACCORDANCE WITH CITY CODE | | | REQUIREMENTS. | | | 2) PLEASE INDICATE MAXIMUM TRAVEL | | | DISTANCES TO REACH EXITS. IT IS PRESUMED | | | THAT THE BUILDING DOES NOT CONTAIN FIRE | | | SPRINKLER PROTECTION. | | | 3) PLEASE PROVIDE INTERIOR FINISH | | | INFORMATION ON WALLS AND CEILINGS. | | | 4) NO DOOR SCHEDULE COULD BE LOCATED | | | IN PLANS. | | | 5) ALL STAIRS TO COMPLY WITH NFPA 101, | | | THE LIFE SAFETY CODE, 1985 EDITION. | | | 6) SEVERAL VOIDED SHEETS CONTAINED IN | | | PLANS. ALSO NOTES MADE TO PLANS THAT ARE | | | NOT DATED OR SIGNED. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2000-11-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-07 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-07 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) PLEASE PROVIDE MORE DETAILS FOR THE | | | WORK/LOFT AREA. | | | 2) PLEASE PROVIDE A LIFE SAFETY PLAN TO | | | EXPLAIN THE EXITING ARRANGEMENT. | | | OCCUPANT LOAD CALCULATIONS ARE TO BE | | | PROVIDED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-10-25 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-10-25 |
Time |
15:42 |
Rev Time |
1.00 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. THE TRAVEL DISTANCE FROM THE MOST | | | REMOTE LOCATION OF THE 2ND FLOOR EXCEED | | | THE TRAVEL DISTANCE REQUIREMENTS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2001-02-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-02-06 |
Time |
12:02 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2001-02-06 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2001-02-06 00:00:00 | ARCHITECT J. SAUNDERS SAID VOID | | | MECHANICAL PERMIT. OWNERS MECH | | | CONTRACTOR WILL SUBMIT PLANS AT TIME OF | | | NEW MECHANICAL PERMIT APPLICATION AND | | | OWNER IS AWARE THAT ADDITIONAL FEES | | | WILL BE DUE AT THAT TIME. GENERAL | | | CONTRACTOR NOTIFIED THAT MECHANICAL WAS | | | BEING PULLED FROM THIS PERMIT AT THIS | | | TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-01-29 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-01-29 |
Time |
14:34 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2001-01-29 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2001-01-29 00:00:00 | *************DENIED********************* | | | 1. SUBMIT DRAWINGS WHERE THE MECHANICAL | | | ELECTRICAL AND ARCHITECTURAL MATCH IN | | | USE AND LAYOUT. UNABLE TO REVIEW UNTIL | | | DRAWINGS MATCH. | | | 2. PROVIDE INFORMATION ON EQUIPMENT | | | INDICATING LOCATION AND TYPE. PROVIDE | | | CURB INFO IF RTU OR PROVIDE PENETRATION | | | INFO IF PACKAGE EQUIPMENT. | | | PROVIDE INFO ON LOCATION OF | | | CONDENSING UNITS FOR SPLIT SYSTEMS. | | | MECHANICAL EQUIPMENT ON ROOF REQUIRES | | | MINIMUM 18" OF CLEARANCE BETWEEN ROOF | | | SURFACE AND BOTTOM OF EQUIPMENT STAND | | | SUPPORT. | | | 3. PROVIDE INFO ON INSTALLATION OF AHU | | | EQUIPMENT, CONDENSATE DRAIN, OVERFLOW | | | PROTECTION, RETURN DUCT OR PLENUM, ETC. | | | 4. DOES DUCT RUN BETWEEN OLD TRUSSES OR | | | NEW FLOOR ASSEMBLY. | | | 5. NEED INFORMATION ON FIRE PROTECTION | | | OF ALL DUCTS PENETRATING RATED FLOORS, | | | CEILING , OR WALLS. | | | 6. PROVIDE INFORMATION ON EXHAUST FANS | | | REQUIRED FOR ALL BATHROOMS TO BE | | | INSTALLED. | | | 7. PROVIDE OUTSIDE AIR SCHEDULE PER | | | ASHRAE 62-89. | | | 8. PROVIDE AIR BALANCE SCHEDULE PER | | | 1997SMC 501.2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-11-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-06 |
Time |
14:01 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-11-06 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************DENIED********************* | | | 1. INSUFFICIENT INFORMATION PROVIDED | | | FOR REVIEW. PROVIDE INFORMATION ON | | | MECHANICAL SYSTEM FOR BOTH FLOORS INCL. | | | ANY REQUIRED FIRE PROTECTION OF RATED | | | PENETRATIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-02-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-02-11 |
Time |
11:17 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-01-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-26 |
Time |
13:10 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
2001-01-26 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-10-22 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-22 |
Time |
07:43 |
Rev Time |
3.75 |
| Received By |
pschmitz |
Date |
2000-10-22 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SHT.SP-1-WATER CLOSETS AND FIXTURE | | | BRANCHES ARE NNOT PERMITTED ON WET VENTS | | | PER COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 911.1.1. | | | | | | 2)RELIEF LINE AND PAN DRAIN FOR WATER | | | HEATER SHALL DISCHARGE TO EXTERIOR PER | | | COUNTYWIDE AMENDMENTS TO SPC SEC.507.6.1 | | | 507.8.3. | | | | | | 3)PAN DRAIN AND PAN SHALL COMPLY W/SPC | | | SEC.507.8.2. | | | | | | 4)SHT.SP-1- SANITARY RISER SHOWS 2 LAVS | | | ON 2ND FLOOR AND SHT.A-2 SHOWS FULL BATH | | | SHOW ALL NEW PLUMBING ON THE SANITARY | | | RISER.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. | | | | | | 5)SHT.A-5-PLANS SHOW 8"STORM DRAIN | | | DISCHARGING INTO 6"LINE.SPC SEC.307.5. | | | | | | 6)INDICATE SLOPE OF STORM DRAIN PIPING | | | ON PLANS.COMPLY W/SPC TABLE 1108.1, | | | 1108.2. | | | | | | 7)SHOW SQ.FT.AREA OF ROOF DRAINED BY EA. | | | ROOF DRAIN.COMPLY W/SPC TABLE 1108.1, | | | 1108.2.INCLUDE 1/2 AREA OF PARAPET WALLS | | | PER SPC SEC.1108.3. | | | | | | 8)SUBMIT CALCULATIONS FOR SECONDARY | | | DRAINAGE.COMPLY W/SPC SEC.1109.2,1109.3, | | | APPENDIX "A"& TABLE A101.2. | | | | | | 9)CLEARLY SHOW DIMENSIONS OF OVERFLOW | | | SCUPPER AND LOCATION OF SCUPPERS ON ROOF | | | PLAN.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. | | | | | | 10)SUBMIT A WATER RISER DIAGRAM FOR | | | REVIEW.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 104.2.1. | | | | | | 11)DRINKING FOUNTAIN SHALL COMPLY W/ | | | FACBC SEC.4.1.3(10)(A).PROVISIONS SHALL | | | BE MADE FOR PEOPLE WHO HAVE TROUBLE | | | BENDING OR STOOPING. | | | | | | 12)2ND.FLOOR BATH SHALL BE FULLY ACCESS- | | | IBLE PER FACBC 4.1.3(11). | | | | | | 13)VERTICAL ACCESSIBILITY SHALL BE | | | PROVIDED TO THE 2ND FLR.PER FACBC SEC. | | | 4.1.3.,FLA.STATUTE 553.509. | | | | | | 14)A DRINKING FOUNTAIN IS REQD.ON THE | | | 2ND.FLOOR PER SPC TABLE 407.DRINKING | | | FOUNTAIN SHALL COMPLY W/FACBC SEC.4.1.3 | | | (10)(A). | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2000-10-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-10-23 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-19 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-08-17 |
Time |
10:52 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DID NOT MEET DMP REQUIREMENTS |
|
|