| Plan Review Stops For Permit 00080502 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-09-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-09-18 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-10-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-25 |
Time |
00:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-25 |
Time |
00:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-29 |
Time |
19:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-29 |
Time |
19:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | | | 1)NOTE: PLEASE SEE 450-13-B OF THE NEC | | | FOR THE INSTALLATION REQ`MENTS OF TRANS- | | | -FORMER. | | | | | | 2)NOTE: PLEASE SHOW LOAD CALCULATIONS TO | | | INCLUDE SQ FT | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-09-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-09-18 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-09-18 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-11 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ON AUGUST 10, 2000, WRITER SPOKE BY | | | TELEPHONE TO SONG AND ASSOCIATES. A | | | LETTER WAS REQUESTED ON THE FLAME SPREAD | | | RATINGS FOR THE INTERIOR FINISHES | | | PLANNED FOR USE. ALSO INFORMATION ON | | | THE MAXIMUM AMOUNT OF OCCUPANTS USING | | | THE SPACE IS NEEDED. THE CODE ALLOWS | | | A SINGLE MEANS OF EGRESS IF OCCUPANT | | | LOADS ARE LESS THAN 100 BUSINESS OR | | | LESS THAN 50 IF ASSEMBLY. WRITER ALSO | | | ADVISED THAT IF ANY REMODEL WORK IS | | | NECESSARY TO THE EXISTING FIRE SPRINKLER | | | SYSTEM, THEN A PLAN AND PERMIT IS | | | REQUIRED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-08-14 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-08-14 |
Time |
14:30 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-08-14 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-16 |
Time |
14:23 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-11-16 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2000-10-28 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-28 |
Time |
04:53 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
2000-10-28 |
Time |
04:56 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)A DRINKING FOUNTAIN IS REQD.PER SPC | | | TABLE 407.FOUNTAIN SHALL COMPLY W/ | | | FACBC SEC.4.15.PROVISIONS SHALL BE MADE | | | FOR PEOPLE WHO HAVE TROUBLE BENDING OR | | | STOOPING PER FACBC SEC.4.1.3.(10)(A). | | | | | | 2)SUBMIT REVISED SANITARY AND WATER | | | RISER DIAGRAMS SHOWING DRINKING FOUNTAIN | | | CONNECTIONS.COUNTYWIDE AMENDMENTS TO | | | SPC SEC.104.2.1. | | | | | | CALL IF YOU HAVE QUESTIONS. | | | 561-659-8096,EXT.8377. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-10-14 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-10-14 |
Time |
11:22 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLBG PLAN REVIEW RESUBMIT | | | (1) APPR AS REVISED. PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-14 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-20 |
Time |
09:20 |
Rev Time |
0.33 |
| Received By |
pschmitz |
Date |
2000-08-20 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SUBMIT OCCUPANT LOAD BASED ON SQ.FEET | | | OF HABITABLE FLOOR SPACE.SEE SPC SEC. | | | 407.1.3. FOR ALLOWED DEDUCTIBLE AREAS. | | | ADDITIONAL PLBG.FIXTURES MAY BE REQD. | | | | | | 2)A DRINKING FOUNTAIN IS REQD.PER SPC | | | TABLE 407.DRINKING FOUNTAIN SHALL COMPLY | | | W/FACBC SECS.4.1.3,4.15.PROVISIONS SHALL | | | BE MADE FOR PEOPLE WHO HAVE TROUBLE | | | BENDING OR STOOPING. | | | | | | 3)SINK IN LOUNGE SHALL COMPLY W/FACBC | | | SEC.4.24.1-4.24.7.MAX.HEIGHT OF CABINET | | | SHALL BE 34"AT CLEAR FLOOR ACCESS AREA. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|