Plan Review Details - Permit 00080474
Plan Review Stops For Permit 00080474
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-08-22 Cont ID  
Sent By dpalmer Date 2000-08-22 Time 18:14 Rev Time 0.00
Received By dpalmer Date 2000-08-22 Time 18:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-17 Cont ID  
Sent By cthirben Date 2000-08-17 Time 09:38 Rev Time 1.00
Received By cthirben Date 2000-08-17 Time 09:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-11-02 Cont ID  
Sent By tlarge Date 2000-11-02 Time 08:14 Rev Time 0.30
Received By tlarge Date 2000-11-02 Time 08:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-08-16 Cont ID  
Sent By tlarge Date 2000-08-16 Time 06:56 Rev Time 0.33
Received By tlarge Date 2000-08-16 Time 06:38 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-11-08 Cont ID  
Sent By jgomez Date 2000-11-08 Time 09:04 Rev Time 1.00
Received By jgomez Date 2000-11-08 Time 09:04 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE ATTIC ACCESS AT FRONT OF
 GARAGE AREA. SEC. 2309.6 SBC 1997.
 2-GENERAL NOTES SHEET TO BE UPDATED AS
 REQUIRED. WE USE SBC 1997 AND FLORIDA
 ENERGY EFFICIENCY CODE FOR BUILDING
 CONSTRUCTION, 1997 EDITION. SEE
 COMMENTS ON PLANS.
 3-PROVIDE STRUCTURAL BUCK DETAIL USING
 A 2X BUCK AS REQUIRED BY THE PRODUCT
 APPROVAL SUBMITTED.
 4-PROVIDE BBQ UL LISTING AND INSTALLAT'N
 SPECIFICATIONS.
 5-PROVIDE PRODUCT APPROVAL FOR FIXED
 TRANSOM WINDOW WITH THE SIZE SHOWN AS
 SHOWN AT FAMILY ROOM.
 6-PROVIDE PRODUCT APPROVAL FOR SLIDING
 GLASS DOORS WITH THREE PANELS AND THE
 SIZE SHOWN AT FAMILY ROOM. PRODUCT
 APPROVAL SUBMITTED DOESN'T COVER THREE
 PANELS WITH THE SIZE SHOWN ON PLANS.
 7-PROVIDE STRUCTURAL BUCK DETAIL USING
 A 2X BUCK FOR FIXED AND ARCHED WINDOWS
 AS REQUIRED BY THE PRODUCT APPROVAL.
 8-SEE PLANS FOR ADDITIONAL COMMENTS.
 INCLUDING THOSE BY THE OTHER TRADES.
  
  
  
 NOTES:
 -IF YOU HAVE ANY QUESTIONS PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.
 -PLEASE UPDATE ALL PLANS AS REQUIRED TO
 AVOID UNNECESSARY RETURNS ON FUTURE
 SUBMITTALS.
 -PROVIDE INFORMATION REQUESTED ON THIS
 PROVISO PRIOR TO INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-11-02 Cont ID  
Sent By jgomez Date 2000-11-02 Time 13:06 Rev Time 3.00
Received By jgomez Date 2000-11-02 Time 13:06 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-IMPACT FEES STILL NOT PAID.
 PAY IMPACT FEES, GET DRAWINGS STAMPED
 AND BRING PAID RECEIPT.
 2-THERE ARE SOME ITEMS THAT CAN BE UNDER
 A PROVISO IF CONTRACTOR AGREES TO
 PROVIDE THEM BEFORE INSTALLATION OR
 CONSTRUCTION.
 3-THERE IS AN ADDITIONAL FEE OF $189.66
 FOR BUILDING VALUATION AND RADON FEES.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-09-12 Cont ID  
Sent By jgomez Date 2000-09-12 Time 17:30 Rev Time 3.00
Received By jgomez Date 2000-09-12 Time 17:30 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY
 AND BRING STAMPED DRAWINGS AND RECEIPT
 2-LEFT SIDE ELEVATION EXCEEDS THE MAX.
 PERCENTAGE OF OPENINGS ALLOWED BY
 TABLE 600 OF SBC 1997.
 3-PROVIDE ONE HOUR FIRE RATED ASSEMBLY
 AT ZERO LOT LINE. INCLUDING AREA AT
 TRANSITION FROM CONCRETE BLOCK TO WOOD
 FRAMING. THE FIRE RESISTANCE FOR
 EXTERIOR WALLS AT ZERO LOT LINE SHALL
 BE UPON BOTH INTERIOR & EXTERIOR FIRE
 EXPOSURE. TABLE 600, NOTE I. SBC/97
 ALSO, SEE SECTION 709.6.2.2 SBC 1997.
 4-SURVEY TO BE SIGNED, SEALED AND DATED
 CHAPTER 471 FLORIDA STATUTES.
 5-PROVIDE SOIL TEST REPORT PERFORMED AS
 PER SECTION 1804.2.7.2 OF CITY
 AMENDMENTS.
 6-ARCHITECTURAL DRAWINGS NEED ORIGINAL
 SIGNATURE. CHAPTER 481 FL. STATUTES.
 7-GENERAL NOTES SHEET TO BE UPDATE AS
 REQUIRED. CITY OF WEST PALM BEACH HAS
 ADOPTED THE SBC 1997 AND FLORIDA
 ENERGY EFFICIENCY CODE FOR BUILDING
 CONSTRUCTION, 1997 EDITION. REVIEW ALL
 DIVISIONS (EG: CONCRETE, MASONRY, ETC)
 AND REFERENCE THE APPROPRIATE STANDARD
 ACCORDING TO SBC AND THE ENERGY CODE
 RESPECTIVELY.
 8-COMPLETELY SPECIFY CEILING CONSTRUCT'N
 AT ENTRY AND REAR PORCHES. INCLUDING
 FASTENERS TYPE AND SPACING. SECTION
 2504.2 SBC 1997.
 9-ATTIC ACCESS IN MASTER BEDROOM CLOSET
 TO BE 22"X36" MIN. SEC. 2309.6 SBC/97.
 SPECIFY SIZE FOR SECOND FLOOR ROOF.
 10-PROVIDE DRAFSTOPPING AT SECOND FLOOR
 FRAMING PLAN. SPECIFY LOCATION AND
 TYPE OF MATERIAL. SEC. 2305.2.2 SBC/97
 11-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM:
 -IMPORTANCE FACTOR IS INCORRECT. SEE
 TABLE 1606 SBC 1997.
 -BASIC VELOCITY PRESSURE IS INCORRECT.
 SEE TABLE 1606.2A SBC 1997.
 -FORM IS NOT LEGIBLE.
 12-PROVIDE PRODUCT APPROVAL FOR:
 -ENTRY DOUBLE DOORS.
 -HORIZONTAL SLIDERS (MISSING DRAWINGS).
 -SLIDING GLASS DOORS (LEGIBLE DRAWINGS)
 -ARCHED WINDOWS (LEGIBLE DRAWINGS).
 -WINDOW MULLIONS (NOTE: TO BE USED WITH
 WINDOWS W/ CURRENT PRODUCT APPROVAL).
 -ONE HOUR FIRE RATED GLASS BLOCK.
 13-PROVIDE BUCK DETAILS SHOWING 2X SIZE
 OF BUCK. SEE PRODUCT APPROVAL FOR
 FIXED AND ARCHED WINDOWS.
 14-SEE PLANS FOR ADDITIONAL COMMENTS.
 INCLUDING THOSE BY THE OTHER TRADES.
 15-STORM PANELS:
 -SPECIFY ANCHORS FOR WOOD FRAMING.
 -WHAT'S AN ANCHOR D?.
 -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS
 ON PAGE 2 OF 5.
  
 NOTES:
  
 1-CONTRACTOR NEEDS TO UPDATE LICENSE.
 PLEASE CONTACT MICHELLE MCLEAN AT
 659-8096 EXT. 8242 OR ANGIE NEIL AT
 EXT. 8289 FOR INFORMATION REQUIRED.
 2-VALUE DECLARED ON THE APPLICATION WAS
 TOO LOW. THIS VALUE WILL BE ADJUSTED
 AND ADDITIONAL FEES WILL BE DUE,
 INCLUDING RADON FEES.
 3-PLEASE RETURN REVIEWED SET OF DRAWINGS
 IN ORDER TO EXPEDITE THE REVIEW
 PROCESS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-08-15 Cont ID  
Sent By gjoyce Date 2000-08-15 Time 12:27 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***