Plan Review Details - Permit 00080127
Plan Review Stops For Permit 00080127
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-09-22 Cont ID  
Sent By dpalmer Date 2000-09-22 Time 11:35 Rev Time 0.00
Received By dpalmer Date 2000-09-22 Time 11:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-09-13 Cont ID  
Sent By dpalmer Date 2000-09-13 Time 12:10 Rev Time 0.00
Received By dpalmer Date 2000-09-13 Time 12:10 Sent To  
Notes
2001-01-08 00:00:00NOTES FROM FIRST REVIEW NOT CLARIFIED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-08-30 Cont ID  
Sent By dpalmer Date 2000-08-30 Time 07:04 Rev Time 0.00
Received By dpalmer Date 2000-08-30 Time 07:04 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: NOT ENOUGH INFORMATION SUBMITTED
 FOR REVIEW. ONLY ELECTRICAL SHOWN IS A
 RISER DIAGRAM?? THIS IS FOR??
 ALSO, UNLESS APPROVED BY ZOING, NO
 SECOND METER WILL BE ALLOWED. IF IT IS
 APPROVED ONLY ONE SERVICE DROP TO HOUSE
 AND MAINS MUST BE GROUPED. PLEASE
 SUBMIT MOER DETAIL ON SERVICE AND HOUSE
 ELECTRICAL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-08-26 Cont ID  
Sent By jleech Date 2000-08-26 Time 09:14 Rev Time 0.33
Received By jleech Date 2000-08-26 Time 09:14 Sent To  
Notes
2001-01-08 00:00:00NO A/C PLANS
 PLANS MUST BE SUBMITED WITH A/C
 APPLICATION.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-09-18 Cont ID  
Sent By tlarge Date 2000-09-18 Time 08:22 Rev Time 0.33
Received By tlarge Date 2000-09-18 Time 08:22 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 1)FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE VENTED.SPC SEC.913.2.
  
 2)SINKS ARE NOT PROPERELY VENTED.SPC SEC
 901.2.
  
 3)SUBMIT REVISED SANITARY RISER DIAGRAM
 PRIOR TO PLUMBING INSPECTION.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-09-02 Cont ID  
Sent By tlarge Date 2000-09-02 Time 07:00 Rev Time 0.33
Received By tlarge Date 2000-09-02 Time 07:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-08-30 Cont ID  
Sent By tlarge Date 2000-08-30 Time 08:33 Rev Time 0.33
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:001)OWNER CANNOT INSTALL GAS PER NFPA 54
 SEC.1.4.INSTALLATION SHALL BE DONE BY
 QUALIFIED PERSONNEL.
  
 2)CLARIFY PSI NOTED ONPLANS.5.0 & 5.8
 PSI EXCEEDS THE NORMAL 1/4 & 1/2 PSI
 DELIVERY PRESSURE TO STRUCTURES.
 SEE SGC SEC.305.4(A).
  
 3)COMPLY W/ATTACHED REQS.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-08-22 Cont ID  
Sent By tlarge Date 2000-08-22 Time 07:40 Rev Time 0.50
Received By tlarge Date 2000-08-22 Time 07:04 Sent To  
Notes
2001-01-08 00:00:00FIXTURES DOWNSTREAM OF WATER CLOSETS
 SHALL BE VENTED.SPC SEC 913.2.
  
 VENT FOR WASHING MACHINE SHALL CONNECT
 TO STACK ABOVE HIGHEST FIXTURE.SPC
 904.2.1.
  
 KITCHEN SHALL CONNECT TO STACK ABOVE
 BATHROOM GROUP.
  
 FIXTURE DRAIN FOR LAVS TO CONNECT TO
 STACK.SPC SEC.901.2.SHOW BOTH LAVS ON
 RISER.
  
 KITCHEN SINK CANNOT BE INSTALLED AS
 DRAWN.COMPLY W/SPC.
  
 SUBMIT REVISED DRAWING FOR REVIEW.
  
 SUBMIT GAS DRAWING FOR REVIEW.SEE
 ATTACHED FOR GAS REQS.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-09-22 Cont ID  
Sent By rmcdouga Date 2000-09-22 Time 15:41 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)IF MARVIN WINDOWS OR DOORS ARE USED,
 2 CURRENT COPIES OF METRO-DADE OR SBCCI
 PRODUCT APPROVALS MUST BE SUBMITTED
 PRIOR TO INSTALLATION.
  
 2)IF IMPACT RESISTANT GLAZING IS NOT
 USED,PRODUCT APPROVALS FOR STORM PANELS
 (IMPACT PROTECTION) MUST BE SUBMITTED
 WITH APPLICATION UNDER A SEPARATE PERMIT

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-09-19 Cont ID  
Sent By rmcdouga Date 2000-09-19 Time 07:20 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)IF MARVIN WINDOWS OR DOORS ARE USED,
 THE ACTUAL METRO-DADE OR SBCCI PRODUCT
 APPROVALS MUST BE SUBMITTED PRIOR TO
 INSTALLATION. THE MEMORANDUM FROM THE
 MANUFACTURER THAT WAS SUBMITTED IS NOT
 ACCEPTABLE.
  
 2)IF USING ROLL-UPS,ACCORDION OR OTHER
 STORM PANELS FOR MISSLE IMPACT
 PROTECTION,THE ACTUAL METRO-DADE OR
 SBCCI PRODUCT APPROVALS MUST BE
 SUBMITTED BEFORE MAIN PERMIT IS ISSUED
 OR SUBMITTED LATER UNDER A SEPARATE
 PERMIT PRIOR TO INSTALLATION. THE
 BROCHURE FROM THE MANUFACTURER IS NOT
 ACCEPTABLE.
  
 3)OWNER OR AGENT MUST SIGN AND DATE THE
 FLORIDA ENERGY EFFICIENCY CODE FORM
 600A-97.
  
 4)IMPACT FEES MUST BE PAID TO PALMCO.
 PLANS STAMPED BY THEM AND COPY OF
 RECEIPT SUBMITTED TO CITY OF WPB BLDG.
 DEPT. BEFORE A PERMIT TO CONSTRUCT WILL
 BE ISSUED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-09-13 Cont ID  
Sent By rmcdouga Date 2000-09-13 Time 08:49 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR ALL
 EXTERIOR WINDOW AND DOOR OPENINGS,
 INCLUDING OVERHEAD GARAGE DOOR.
  
 2)PROVIDE PRODUCT APPROVALS FOR IMPACT
 RESISTANT GLASS OR STORM PANELS.
  
 3)SAFETY GLASS REQUIRED IN BATHROOM
 WINDOW AND WINDOW ADJACENT TO FRONT DOOR
 SEC.2405.2,97 SBC
  
 4)DRAWING A-1 SITES SSTD 10-93. THE
 DESIGN CRITERIA MUST COMPLY WITH SEC.
 1606 97 SBC OR SSTD 10-97.PLEASE CORRECT
  
 5)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY,PLANS STAMPED BY THEM AND COPY OF
 THE RECEIPT SUBMITTED TO CITY OF W.P.B.
 BUILDING DEPT. BEFORE A PERMIT TO
 CONSTRUCT WILL BE ISSUED.
  
 6)COPY OF SOIL REPORT RETAINED FOR
 PUBLIC RECORD MUST BE SIGNED,SEALED AND
 DATED (WET SIGNATURE) BY THE ENGINEER.
  
 7)SHEET S-1 MUST BE SIGNED,SEALED AND
 DATED (WET SIGNATURE) BY THE ENGINEER.
  
 8)INSERT ON SHEET S-1 IS OUT-OF-DATE.
 THE CORRECT CODE EDITION IS 1997 SBC OR
 ASCE 7-95. PLEASE CORRECT.
  
 9)MEAN ROOF HEIGHT LISTED ON SHEET S-1
 AND ONE ON DESIGN COMPLIANCE DO NOT
 AGREE.PLEASE CORRECT.
  
 10)WALL SECTION SHOWN ON SHEET S-1 DOES
 NOT CORRESPOND WITH SECTION SHOWN ON
 DRAWING A-7. PLEASE CORRECT.
  
 11)PROVIDE POSITIVE AND NEGATIVE DESIGN
 PRESSURES FOR COMPONENTS AND CLADDING
 WITH RESPECT TO APPROPRIATE WIND LOAD
 ZONES.(WINDOWS,DOORS,ETC.)
  
 12)PROVIDE ENERGY CODE CALCULATIONS
 INCLUDING MANUAL "J" CALCS. PER 1997 FL
 ENERGY EFFICIENCY CODE.
  
 13)PROVIDE WINDOW AND DOOR DIMENSIONS
 AND TYPES (SINGLE HUNG,FIXED,ETC.)
  
 14)PROVIDE EGRESS WINDOW IN SLEEPING
 ROOMS. SEC.1005.4.1 97 SBC
  
 15)PROVIDE ATTIC ACCESS.SEC.2309.6 97SBC
  
 16)PROVIDE STAIR DETAIL WITH TREAD AND
 RISER DIMENSIONS SHOWN.
  
 17)EXTERIOR EXIT STAIRS; PORCHES AND
 STAIRWAYS SHALL BE LOCATED AT LEAST 10FT
 FROM ADJACENT PROPERTY LINES AND FROM
 OTHER BUILDINGS ON THE SAME LOT,UNLESS
 OPENINGS IN SUCH BUILDINGS ARE PROTECTED
 BY 3/4-HOUR FIRE RESISTANT DOORS OR
 WINDOWS. SEC.1006.2 97 SBC. PLEASE
 CLARIFY COMPLIANCE WITH THIS CODE.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-09-15 Cont ID  
Sent By gjoyce Date 2000-08-17 Time 11:31 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***