Plan Review Details - Permit 00080012
Plan Review Stops For Permit 00080012
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-01-16 Cont ID  
Sent By btrobaug Date 2002-01-16 Time 10:28 Rev Time 0.50
Received By btrobaug Date 2002-01-16 Time 09:53 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-08-01 Cont ID  
Sent By dpalmer Date 2000-08-01 Time 19:09 Rev Time 0.00
Received By btrobaug Date 2000-08-01 Time 19:09 Sent To  
Notes
2001-01-08 00:00:00*************** PROVISO ***************
  
 1)NOTE: PLEASE SUBMIT REVISED PANEL
 SCHEDULE/LOAD CALCULATION. LIST THE REQ`
 BATH(S) CIRCUIT PER 210-11-C-3
  
 2)NOTE: PLEASE NOTE ARTS: 210-52-C-1,2,3
 4,5 OF NEC FOR KITCHEN REQ`MENTS OF
 OUTLETS.
  
 3)NOTE: PLEASE SHOW EXISTING SERVICE
 SIZE.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW BEFORE ANY ROUGH ELECTRICAL
 INSPECTION IS CALLED IN. IF THERE ARE
 ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-01-16 Cont ID  
Sent By hmoser Date 2002-01-16 Time 18:46 Rev Time 0.33
Received By pkrauss Date 2002-01-16 Time 18:46 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-03-08 Cont ID  
Sent By btrobaug Date 2002-01-16 Time 10:29 Rev Time 0.25
Received By pkrauss Date 2001-03-08 Time 12:05 Sent To  
Notes
2001-03-08 00:00:00NOTE:NEW BATHROOM MUST COMPLY WITH
 1997 SMC 503.3.1, SHALL HAVE AN
 OPERABLE WINDOW OR EXHAUST FAN.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-08-03 Cont ID  
Sent By cthirben Date 2000-08-03 Time 08:17 Rev Time 1.00
Received By cthirben Date 2000-08-03 Time 08:17 Sent To  
Notes
2001-01-08 00:00:00NO MECHANICAL PLANS SUBMITTED AT THIS
 TIME FOR REVIEW, MECHANICAL CONTRACTOR
 WILL APPLY FOR SEPERATE MECH. PERMIT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-01-26 Cont ID  
Sent By pschmitz Date 2002-01-26 Time 08:58 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2002-01-26 00:00:00PROVISO: ON DWV ISOMETRIC, PER CODE.
 SEPERATE PLANS & PERMIT FOR GAS.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 7

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-10-31 Cont ID  
Sent By pkrauss Date 2002-01-22 Time 12:21 Rev Time 0.33
Received By kstevens Date 2001-10-31 Time 09:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-08-02 Cont ID  
Sent By tlarge Date 2000-08-02 Time 09:13 Rev Time 0.33
Received By tlarge Date 2000-08-02 Time 09:13 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY RISER PRIOR TO PLUMBING
 INSPECTION.

Review Stop R ROOF PLAN REVIEW
Rev No 10 Status P Date 2002-01-29 Cont ID  
Sent By rmcdouga Date 2002-01-29 Time 08:53 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 9 Status P Date 2001-12-18 Cont ID  
Sent By rmcdouga Date 2001-12-18 Time 16:00 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 8 Status P Date 2001-12-15 Cont ID  
Sent By rmcdouga Date 2001-12-15 Time 08:35 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-15 00:00:00OK WITH LETTER FROM ENGINEER.RM

Review Stop R ROOF PLAN REVIEW
Rev No 7 Status F Date 2001-12-12 Cont ID  
Sent By rmcdouga Date 2001-12-12 Time 09:25 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-12 00:00:00*************BUILDING UNSAT*************
  
 1) PROVIDE ENGINEERING ANALYSIS OF WIND
 AND GRAVITY LOADS FOR PROPOSED ROOF
 OVERHANG EXTENSION.
  
 2) INDICATE THE FRAMING CONNECTOR THAT
 WILL BE USED TO ATTACH THE LOOKOUT
 RAFTERS TO THE DOUBLE 2"X 12" JOIST/
 RAFTER.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status P Date 2001-12-03 Cont ID  
Sent By rmcdouga Date 2001-12-03 Time 12:36 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-12-03 00:00:00PROVISO
 1) EXTERIOR DOOR INSTALLATION MUST
 COMPLY WITH REQUIREMENTS OF PRODUCT
 APPROVAL.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2001-12-03 Cont ID  
Sent By rmcdouga Date 2001-12-03 Time 12:36 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2001-11-06 Cont ID  
Sent By rmcdouga Date 2001-11-06 Time 17:25 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-11-13 00:00:00REVISION OK

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-11-03 Cont ID  
Sent By rmcdouga Date 2001-11-03 Time 09:21 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-11-03 00:00:00*************BUILDING UNSAT*************
  
 1) THE GLAZING IN THE RELOCATED BATHROOM
 WINDOW IS REQUIRED TO BE SAFETY GLASS
 PER 97 SBC SEC.2405.2.1 (3), WHEN
 LOCATED WITHIN A 24-INCH RADIUS OF A
 DOOR IN THE CLOSED POSITION. PLEASE
 INDICATE ON PLANS.
  
 2) PROVIDE MANUFACTURERS SPECIFICATIONS
 FOR GLASS BLOCK (2 COPIES). PROVIDE (2)
 DRAWINGS INDICATING STRUCTURAL DETAILS
 OF GLASS BLOCK WALL INSTALLATIONS WHICH
 SHOW STRUCTURAL SUPPORTS, JOINT
 REINFORCEMENT, ETC. THE GLASS BLOCK
 SHALL HAVE A MINIMUM THICKNESS OF 3" AT
 THE MORTAR JOINT AND ALL THE MORTAR-
 BEARING SURFACES SHALL BE TREATED FOR
 MORTAR BONDING. 97SBC SEC.2112. WHEN
 INSTALLED IN HAZARDOUS LOCATIONS GLASS
 BLOCK IS REQUIRED TO HAVE A UNIFORM FACE
 THICKNESS OF 0.25 INCH PER 97SBC SECTION
 2405.2.2 (5). PLEASE INDICATE SPECIFIC
 TYPE OF GLASS BLOCK THAT IS TO BE
 INSTALLED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-03-08 Cont ID  
Sent By fknapp Date 2001-03-08 Time 12:54 Rev Time 4.00
Received By fknapp Date 2001-03-08 Time 12:54 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-09-13 Cont ID  
Sent By fknapp Date 2000-09-13 Time 12:13 Rev Time 4.00
Received By fknapp Date 2000-09-13 Time 12:09 Sent To  
Notes
2001-01-08 00:00:00 
  
 *************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1)PROVIDE 2 COMPLETE CURRENT COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 A)ALL NEW EXTERIOR DOORS AND WINDOWS
 B)ROOF COVERING UNDER SEPARATE
 C)STORM PANELS INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN
 WITH SPECIFIC ANCHORS TO BE USED
  
 2)PROVIDE SOIL REPORT
  
 3)PROVIDE RAISE SEAL OF ENGINEER ON
 SHEETS THAT ENGINEERS NAME IS ON
  
 4)PROVIDE REVISED PLANS TO COMPLY WITH
 1997 SBC TABLE 600 FOR OPENINGS ON NORTH
 WALL OF BUILDING
  
 5)PROVIDE ENERGY CALCULATIONS
  
 6)PROVIDE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE
  
 7)PROVIDE WINDOW AND DOOR BUCK
 CONNECTION DETAILS FOR WINDLOAD
 RESISTANCE 1997 SBC 1606
  
 8)PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE WITH FINISH FLOOR ELEVATION
 OF ADDITION MIN 7.5' OR GREATER
  
 9)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO., THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-08-15 Cont ID  
Sent By gjoyce Date 2000-08-15 Time 09:12 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***