Plan Review Details - Permit 00071404
Plan Review Stops For Permit 00071404
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-11-27 Cont ID  
Sent By hpiskura Date 2000-11-27 Time 07:45 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:00LETTER W/APPLICATION

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-09-12 Cont ID  
Sent By hpiskura Date 2000-09-12 Time 15:03 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-11-19 Cont ID  
Sent By dpalmer Date 2001-11-19 Time 21:25 Rev Time 0.00
Received By dpalmer Date 2001-11-19 Time 21:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-11-21 Cont ID  
Sent By dpalmer Date 2000-11-21 Time 20:54 Rev Time 0.00
Received By dpalmer Date 2000-11-21 Time 20:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-08-29 Cont ID  
Sent By dpalmer Date 2000-08-29 Time 19:22 Rev Time 0.00
Received By dpalmer Date 2000-08-29 Time 19:22 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASE SEE PANEL "L1" THIS REQ`S
 A MCB ON THE LOAD SIDE OF TRANSFORMER
 BEING A SEPARATELY DERIVED SYSTEM.
  
 2)NOTE: PLEASE PROVIDE MORE DETAIL ON
 LOAD CALCULAITONS. SQ.FT/CONTINUOUS LOAD
 -S AT 125%.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
  
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2000-11-02 Cont ID  
Sent By csiegber Date 2004-07-01 Time 14:55 Rev Time 1.00
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00PASSED WITH PROVISOS
 1. COMPLETE NEW SIDEWALK ALONG SITE.
 2. BACKFLOWS MUST BELOCATED OUTSIDE OF W
 ALL.
 3. FIRE HYDRANT MUST BE INSTALLED AND LO
 CATED PER CITY OF WEST PALM BEACH STANDA
 RD DETAIL.561-659-8040 EXT. 2303
 4. A HEALTH DEPARTMENT PERMIT IS REQUIRE
 D THROUGH PUBLIC UTILITIES ENGINEERING S
 ERVICES DIVISION.
 MANNY GONZALEZ 561-659-8040 EXT. 2306
 5. MISSING VALVE DETAIL AND SAMPLE POINT
 DETAIL. CALL JANICE A 561 659 8040EX2303
 6. WATERMAIN MUST BE DIP CEMENT-LINED
 CLASS 52.
 7. ANY CURB OR SIDEWALK THAT WILL BE CUT
 OR DAMAGED DURING INSTALLATION OR CONS-
 TRUCTION OF THE WATERMAIN MUST BE REPLAC
 ED TO EQUAL OR BETTER CONDITION.
 8. FIRE HYDRANT LOCATION MUST BE APPROVE
 D BY FIRE DEPARTMENT PRIOR TO FINAL
 APPROVAL OF WATERMAIN.
 9. MUST MAINTAIN 18" MIMIMUM CLEARANCE
 BETWEEN WATER AND SEWER.
 10. TO WHAT ADDRESS DO CHARGES WILL
 APPLY 420 OR 424 HAMPTON.PLEASE
 CONTACT MANNY.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2000-09-19 Cont ID  
Sent By mgonzale Date 2000-09-19 Time 15:47 Rev Time 1.00
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00CONTINUATION...
 EVERY SIX MONTHS AFTER CONSTRUCTION A
 P.E. SHALL CERTIFY THAT THE PERMANENT
 POLLUTION PREVENTION STRUCTURES, DRY-WET
 WATER DETENTION FACILITIES, AND
 EXFILTRATION SYSTEMS ARE WORKING AS
 DESIGNED AND ARE IN GOOD OPERATING
 CONDITION.
  
 ALL CERTIFICATIONS MUST
 BE SUBMITTED TO:
 STORM WATER UTILITY ENGINEER
 CITY OF WEST PALM BEACH PUBLIC UTILITIES
 DEPARTMENT
 P.O. BOX 3366, WEST PALM BEACH, FL 33402
 THE CERTIFICATION MUST INCLUDE THE BUILD
 PERMIT NUMBER, THE ADDRESS OF THE PROPER
 AND THE NAME OF THE ESTABLISHMENT/PROJEC
 CONSTRUCTED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2000-09-19 Cont ID  
Sent By mgonzale Date 2000-09-19 Time 14:51 Rev Time 2.00
Received By mgonzale Date   Time   Sent To  
Notes
2001-01-08 00:00:00UPON REVIEWING THE ABOVE REFERENCED
 PROJECT THE FOLLOWING ITEMS WILL NEED
 TO BE ADDRESSED:
  
 SHEET C2 CALLS OUT REMOVING DRIVEWAY
 ENTRANCES THAT ARE NOT NEEDED, PLACE
 A NOTE THAT CONTRACTOR SHALL REPLACE
 DRIVEWAYS TO BE REMOVED WITH NEW SIDE-
 WALK AND CURB TO MATCH EXISTING (TYP)
  
 SHEET C3.00
 A POLLUTION PREVENTION PLAN MUST BE
 PROVIDED SHOWING A SILT FENCE AROUND
 THE ENTIRE SITE AND A SILT FENCE INSTALL
 ATION DETAIL.THIS PLAN MUST CONTAIN
 THE SITE INFORMATION AS SHOWN ON SHEET
 C-1.00. YOU MAY COMBINE THE SITE PLAN
 AND POLLUTION CONTROL PLAN TOGETHER.
 (SITE PLAN AND POLLUTION CONTROL PLAN)
  
 SHEET C-4.00
 A CLEAN-OUT IS REQUIRED AT THE POINT OF
 SEWER ENTERING THE BUILDING AND AT THE
 BACK OF SIDEWALK. CONTRACTOR SHALL
 VERIFY THE CLEAN-OUT IS IN PLACE OR
 CUT ONE INTO EXISTING SEWER SERVICE.
  
 SHEET C-4.00
 THE CITY OF WEST PALM BEACH DOES NOT
 ALLOW 3" FIRELINES.IT MUST BE A 2"
 WITH A 2" VALVE. THE OTHER OPTION WOULD
 BE TO RUN A NEW 8" WM ALONG HAMPTON OFF
 DIXIE HWY. TO THEN SERVE THIS BUILDING
 WITH A 4" FIRELINE.
  
 SHEET C-4.00
 A VALVE MUST BE PROVIDED TO SEPERATE
 PRIVATE FIRE LINE AND WATER SERVICE LINE
 SO THAT WHEN ONE IS DOWN FOR SERVICE
 THE OTHER WOULD BE IN OPERATION.
  
 SHEET C-4.00
 PLACE METER IN SIDEWALK WITH LOCKING LID
 AND TOUCHREAD OPTION.
  
 GENERAL COMMENT:
 PLEASE LABEL PROPERTY LINE OR SHOWN IN A
 DIFFERENT LINE TYPE.
  
 IN STANDARD DETAIL SHEET PLEASE
 PROVIDE THE FOLLOWING:
 CWPB TYPICAL TRENCH DETAIL OR PAVEMENT
 REPLACEMENT DETAIL.
  
 GENERAL NOTES:
 1.A SEPARATE IRRIGATION METER IS
 SUGGESTED TO SAVE ON THE MONTHLY
 WATER BILL. AN APPROVED BACKFLOW
 PREVENTER WILL NEED TO BE INSTALLED
 ON THIS LINE.
  
 2.NO WATER AND OR SANITARY LINES CAN BE
 LAID, IF PLANS ARE NOT SUBMITTED TO US,
 SEPARATELY AND PRIOR TO SUBMITTAL FOR A
 BUILDING PERMIT FROM BUILDING AND ZONING
 ANDSERVICE WILL NOT BE GRANTED.
 SUBMITT TO MANNY GONZALEZ
 PUBLIC UTILITIES PROJECT SPECIALIST
 1000 45TH STREET
 WEST PALM BEACH, FL 33415
 (561) 659-8040 EXT. 2306
 (2 SETS MINIMUM)
  
 3.ALL BROKEN SIDEWALKS ALONG THE PROPERT
 Y MUST BE REPLACED.
  
 4.ALL DRIVEWAYS THAT WILL NOT BE USED MU
 ST REMOVED AND THE REGULAR CURBS
 (&GUTTERS)MUST BE REPLACED.
  
 5.ALL BROKEN UP CURBS (& GUTTERS)
 MUST BE REPLACED.
  
 6.ALL DRIVEWAY APPROACHES MUST BE (AT A
 MINIMUM) PER CITY STANDARD DETAIL INDEX.
  
 7.ALL GRADES FOR CITY SIDEWALKS WILL BE
 SET BY THE CITY SURVEY CREW, CALL 659-80
 40ASK FOR ED RYAN TO SET UP AN
 APPOINTMENT.
  
 8. NO DUMPSTER IS SHOWN. THIS SITE WILL
 NOT GENERATE TRASH>????
  
 POLLUTION PREVENTION PLAN MUST BE KEPT
 ON SITE AT ALL TIMES DURING CONSTRUCTION
 THE PLAN SHALL BE INSTALLED IN THE FIELD
 PRIOR TO ANY EARTHWORK.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-11-16 Cont ID  
Sent By mcarsill Date 2001-11-16 Time 15:11 Rev Time 0.00
Received By mcarsill Date 2001-11-16 Time 15:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-11-27 Cont ID  
Sent By mcarsill Date 2000-11-27 Time 08:44 Rev Time 0.00
Received By mcarsill Date 2000-11-27 Time 08:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-08-24 Cont ID  
Sent By mcarsill Date 2000-08-24 Time 14:12 Rev Time 0.00
Received By mcarsill Date   Time   Sent To  
Notes
2001-01-08 00:00:001) HOW DOES THE FIRE RESCUE DEPARTMENT
 ENTER THE GATED AREA TO PROVIDE
 SERVICES. FIRE AND PARAMEDICAL UNITS
 MUST BE ABLE TO ENTER THE PARKING AREA.
 2) BUILDING ADDRESS TO MEET CITY CODE
 REQUIREMENTS.
 3) PROVIDE MORE INFORMATION ON THE
 PRE-ACTION FIRE SPRINKLER SYSTEM PLANNED
 FOR USE.
 4) PROVIDE COMPLETE FIRE ALARM SYSTEM
 DRAWINGS. CUT SHEETS ON DEVICES PLANNED
 FOR USE ARE TO BE PROVIDED. A WIRING
 DIAGRAM AND BATTERY CALCULATIONS ARE
 TO BE PROVIDED. A SEPARATE PLAN AND
 PERMIT ARE REQUIRED.
 5) CAN THE EXIT DOORS LOCATED AT THE
 STAIRTOWERS ON LEVEL TWO SWING IN THE
 DIRECTION OF EXIT TRAVEL.
 6) PROVIDE MORE DETAILS ON GENERATOR.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-01 Cont ID  
Sent By csiegber Date 2004-07-01 Time 14:55 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 14:55 Sent To ENG
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-11-21 Cont ID  
Sent By pkrauss Date 2001-11-21 Time 16:51 Rev Time 0.45
Received By pkrauss Date 2001-11-21 Time 16:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-11 Cont ID  
Sent By cthirben Date 2000-08-11 Time 15:39 Rev Time 1.00
Received By cthirben Date 2000-08-11 Time 15:39 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 PROVIDE THE ENERGY EFFICIENCY RATING OF
 SYSTEM AS PER FLORIDA ENERGY EFFICIENCY
 CODE.....
 FAN SHUTDOWN BY SMOKE DETECTOR WITH
 NOTIFICATION BY FIRE ALARM SYSTEM OR
 TIED-IN TO HORN AND STROBE AS PER NFPA
 90A 4.4.4.2. OR 4.4.4.3....
 *SEPERATE PERMIT FOR FIRE SUPPRESSION
 SYSTEM AS PER NFPA.....

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-11-02 Cont ID  
Sent By tlarge Date 2000-11-02 Time 16:51 Rev Time 0.75
Received By tlarge Date 2000-11-02 Time 16:51 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 SUBMIT SIGNED AND SEALED DETAIL FOR
 CONDENSATE PIT.COMPLY W/SMC 1997 ED.
 SEC.304.8.5.
  
 2)A MIN.CLEAR FLOOR SPACE OF 66"X48"
 SHALL BE PROVIDED FOR THE WATER CLOSET.
 UTILITY SINK CANNOT INFRINGE ON THE
 CLEAR FLOOR SPACE.FACBC SEC.4.16.2,
 FIG.28.
  
 CALL IF YOU HAVE QUESTIONS.
 561-659-8096,EXT.8377.
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-08-11 Cont ID  
Sent By tlarge Date 2000-08-11 Time 18:37 Rev Time 2.00
Received By tlarge Date 2000-08-10 Time 23:03 Sent To  
Notes
2001-01-08 00:00:001)A WATER USE PERMIT FOR THE IRRIGATION
 SYSTEM IS REQD.FROM SO.FLA.WATER MNGMT.
 DISTRICT PER FLA.STATUTE 373.219.A WELL
 DRILLING WILL ALSO BE REQD.
  
 2)A PERMIT FOR THE WELL WILL ALSO BE
 REQD.FROM FLA.DEPT.OF HEALTH.COUNTYWIDE
 AMENDMENTS TO SPC SEC.101.4.7.
  
 3)SHT.M-3-CONDENSATE DRAIN CANNOT
 CONNECT DIRECTLY TO THE STORM DRAINAGE
 SYSTEM.CONNECTION SHALL BE MADE BY
 INDIRECT WASTE AND ON EXTERIOR.SPC 804.3
 SMC SEC.304.8.3.
  
 4)HANDICAP DRINKING FOUNTAIN SHALL
 COMPLY W/FACBC SEC.4.1.3.(10)(A).
 PROVISIONS SHALL BE MADE FOR PEOPLE WHO
 HAVE TROUBLE BENDING OR STOOPING.
  
 5)GRAB BAR ALONGSIDE WATER CLOSET SHALL
 BE 42"PER FACBC SEC.4.16.4,4.26,FIG.29.
  
 CALL 561-659-8096 IF YOU HAVE ANY
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-05-11 Cont ID  
Sent By lsmith Date 2001-05-10 Time 13:48 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2001-05-10 00:00:00SITE PLAN DOES NOT MATCH APP SITE PLAN
 SEE RANDALL GRANBERRY 659-8031


Account Summary | Usage Policy | Privacy Policy