Plan Review Details - Permit 00071134
| Plan Review Stops For Permit 00071134 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-09-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-09-06 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-12-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-21 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-21 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-23 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-23 |
Time |
06:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************* PROVISO ****************** | | | | | | 1)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. | | | | | | 2)NOTE: PLEASE SUBMIT ALL AIC RATINGS | | | FOR ALL EQUIPMENT. THIS IS TO BE SUBMIT- | | | -TED ON E-SHEET AND BY ENGINEER OF RE- | | | -CORD.THIS IS TO BE SHOWN ON PLANS. | | | A MIN.RATING IS REQ`D. IF A HIGHER AIC | | | RATING IS INSTALLED THEN THAT WILL BE | | | ACCEPTED. PER 110-9/215-5 OF NEC. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW BEFORE ANY ELECTRICAL | | | INSPECTION IS CALLED IN. IF THERE ARE | | | ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-08-29 |
Time |
15:40 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED WITH PROVISO | | | CONTRACTOR MUST USE THE SILT SCREEN | | | FENCE ALONG THE PERIMETER OF SITE TO | | | CONTAIN ALL CONSTRUCTION DEBRIS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-18 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-08-18 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO BUILDING ADDRESS SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS | | | IS TO COMPLY WITH CITY CODE REQUIREMENTS | | | 2) HOW DOES FIRE RESCUE ENTER SITE | | | THROUGH PROPOSED DOUBLE SWING GATE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-08-24 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-24 |
Time |
15:29 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-08-24 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | FAN SHUT DOWN BY DUCT SMOKE DETECTOR | | | REQUIRED PER 1997 SMC -406 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-08-20 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-20 |
Time |
06:22 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-08-20 |
Time |
06:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ******************PROVISO*************** | | | SCUPPERS SHALL BE SIZED PER SPC 1109.3, | | | FIGURE 1109.3.INCLUDE 1/2 AREA OF ANY | | | VERTICAL WALLS PER SPC SEC.1108.3. | | | SEE SPC APPENDIX"A",TABLE A101.2. | | | SUBMIT DIMENSIONS OF SCUPPERS.DETAILS | | | SHALL BE SIGNED AND SEALED BY DESIGN | | | PROFESSIONAL. | | | | | | 2)SCUPPERS SHALL COMPLY W/SBC SEC. | | | 1517.6.4. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-08-17 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-08-10 |
Time |
08:27 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |