Plan Review Details - Permit 00071007
| Plan Review Stops For Permit 00071007 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-09-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-09-11 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-25 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-25 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** PROVISO **************** | | | | | | 1)NOTE:PLEASE SUBMIT LOAD CALCULATIONS | | | SHOWING ALL CONTINUOUS LOADS AT 125% | | | FOR COMMERCIAL BUILD OUT SPACE. | | | | | | 2)NOTE: PLEASE NOTE SMOKE DETECTORS ARE | | | REQ`D INSIDE AND OUTSIDE SLEEPING ROOMS. | | | NFPA-72 2-2.1.1.1 | | | | | | 3)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED. 210-8-A-6 | | | | | | 4)NOTE: PLEASE SEE 210-8 FOR OUTLETS | | | WITHIN AREA OF WET-BAR. | | | | | | 5)NOTE: PLEASE LIST THE REQ`D DEDICATED | | | BATH(S) CIRCUIT(S) 210-11-C-3 ON PANEL | | | SCHEDULES. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW BEFORE FINAL ELECTRICAL | | | INSPECTION IS CALLED IN. IF THERE ARE | | | ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-21 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) ON AUGUST 16, 2000, WRITER MET WITH | | | PETER RUSSO OF METRO DESIGN GROUP. MR. | | | RUSSO RED LINED A SET OF THE DRAWINGS | | | INDICATING THAT SMOKE DETECTORS WILL BE | | | INSTALLED AND THAT ESCAPE WINDOWS ARE | | | PRESENT AT THE SECOND FLOOR LEVEL. | | | PLEASE SEE PLANS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-08-29 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-29 |
Time |
11:24 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-08-29 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | 1. MIN. CLEARANCE OF 18" REQUIRED BETWEE | | | ROOF SURFACE AND BOTTOM OF MAIN SUPPORT | | | STRUCTURE OF STAND | | | 2. BATH EXHAUST TO BE PROVIDED PER 1997 | | | SMC 503.3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-08-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-08-07 |
Time |
13:23 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|