Plan Review Details - Permit 00070919
| Plan Review Stops For Permit 00070919 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-08-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-19 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING COMMENTS | | | ------------------- | | | | | | 1]PROVIDE ACCESSIBLE TRANSACTION COUNTER | | | AT NEW ADMINISTRATION AREA,[SECT.7.2 | | | 1997 FAC]. | | | 2]SUBMIT PRODUCT TESTING FOR NEW STORE | | | FRONTS. | | | 3]SUBMIT ENERGY CALCULATIONS. | | | 4]PAY COUNTY IMPACT FEES,CITY RADON FEES | | | | | | | | | REVIEWED BY; | | | LUIS MARTINEZ | | | 659-8096#8456 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-11 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-11 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE:PLEASE SEE LOCAL AMENDMENTS FOR | | | OUTLET SPACING ALONG WALL/FIXED GLASS | | | PANELS. FLOOR BOXES MAY BE INSTALLED FOR | | | THIS REQ`MENT. 210-50 | | | | | | 2)NOTE:PLEASE SEE ART 210-62 OF NEC FOR | | | SHOW WINDOW OUTLETS REQ`D. LOAD CALCS | | | PER 220-12-A | | | | | | 3)NOTE: PLEASE SUBMIT REVISED PANEL | | | SCHEDULE WITH BRANCH CIRCUITS THAT | | | CORRELATE WITH PLAN LAYOUT. | | | | | | 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | OF EXISTING BLDG AND NEW AREA BEING ADD- | | | -ED. ALL CONTINUOUS LOADS TO BE FIGURED | | | AT 125%. LIGHTING ETC. IF CIRCUITS #`S | | | 41,42 ARE BEING USED THEN IS PANEL FULL? | | | IF SO IT WILL BE REQD TO PLACE SUB PANEL | | | TO MAINTAIN TWO SPARE LOCATIONS. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-08-19 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED BY RHETT ON 8/2/00LM |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-28 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-28 |
Time |
15:46 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-28 |
Time |
15:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-22 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-08-22 |
Time |
10:17 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS LEVEL 1 SITE PLAN REVIEW |
|
|
|