| Plan Review Stops For Permit 00070819 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-11 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-08-11 |
Time |
12:34 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-08-11 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-08-04 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-08-04 |
Time |
09:05 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-08-04 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | 1. SIGN TO BE PERMITED SEPERATLY | | | 2. FIRE SPRINKLER PERMIT TO BE ISSUED | | | PRIOR TO BUILDING PERMIT BEING ISSUED. | | | 3. SUBMIT LETTER FROM SPECIAL INSPECTOR | | | RELEASEING SUITE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-10 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-10 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-31 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-31 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT******************* | | | | | | 1)NOTE:PLEASE SUBMIT PANEL "D" WITH | | | COMPLETE INFORMATION ON PANEL LIKE PANEL | | | 'A'. | | | | | | 2)NOTE: PLEASE COMPLETE LOAD CALCULATION | | | -S SHOWING ALL CONTINUOUS LOADS AT 125% | | | (LIGHTING, SHOW WINDOW REC AND ALL LOADS | | | FOR TRACK LIGHTING PER 210-62 AND 220-12 | | | -B. PLEASE ADJUST. | | | | | | 3)NOTE: PLEASE PROVIDE AIC RATINGS FOR | | | ALL EQUIPMENT MAINS AND PANELS. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-08-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-09 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) WRONG LIFE SAFETY CODE REFERENCED | | | ON PLANS. SHOULD READ THE 1985 LIFE | | | SAFETY CODE INSTEAD OF 1997 LIFE SAFETY | | | CODE. | | | 2) FIRE SPRINKLER PLAN ALREADY SUBMITTED | | | AND REVIEWED BY FIRE RESCUE, SEE PERMIT | | | 70570. | | | 3) SUBMIT COMPLETE FIRE ALARM SYSTEM | | | PLANS AND PERMIT TO BUILDING DEPARTMENT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-11 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-08-11 |
Time |
11:22 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-08-11 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-07-21 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-21 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-07-21 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2.. | | | FIRE/SMOKE DAMPER DETAIL AND LOCATION IS | | | REQUIRES AT RATED WALLS. | | | DUCT MATERIAL SCHEDULE REQUIRED. | | | PROVIDE EXHAUST FANS DETAIL. | | | ENERGY EFFICIENCY RATING REQUIRED PER | | | FLORIDA ENERGY EFFICIENCY CODE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-08-09 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-09 |
Time |
18:08 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-08-09 |
Time |
18:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-07-22 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-07-22 |
Time |
10:11 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW | | | (1A) SHT A-1,H/C REST RM #2 DOOR SWING, | | | IN TURNING RADIUS OF WHEEL CHAIR, | | | COMPLY FACBC 4.15.5,CLEAR FLR SPACE. | | | (B) DRINKING FOUNTAIN, CLEAR FLR SPACE, | | | COMPLY W/FACBC 4.15.5 | | | (2) SHT P-1 WATER ISOMETRIC,SPC 94 CNTY | | | WIDE AMD. SEC 607.7 NO MORE THAN 2 | | | FIXTURES SHALL BE SUPPLIED WITH 1/2" | | | COLD WATER SUPPLY. | | | END OF COMMENTS |
|
|