Plan Review Details - Permit 00070798
Plan Review Stops For Permit 00070798
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-09-01 Cont ID  
Sent By dpalmer Date 2000-09-01 Time 11:45 Rev Time 0.00
Received By dpalmer Date 2000-09-01 Time 11:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-08-16 Cont ID  
Sent By lsmith Date 2000-08-16 Time 09:40 Rev Time 0.50
Received By dpalmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00PER DVP 7/28/00

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-07-22 Cont ID  
Sent By cthirben Date 2000-07-22 Time 09:00 Rev Time 1.00
Received By cthirben Date 2000-07-22 Time 09:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-07-28 Cont ID  
Sent By jleech Date 2000-07-22 Time 10:54 Rev Time 0.25
Received By jleech Date 2000-07-28 Time 07:31 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 8 Status F Date 2001-01-11 Cont ID  
Sent By jgomez Date 2001-01-11 Time 11:32 Rev Time 1.00
Received By jgomez Date 2001-01-11 Time 11:32 Sent To  
Notes
2001-01-11 00:00:00SET OF DRAWINGS WAS SUBMITTED FOR
 RE-STAMPING SO CONTRACTOR CAN CALL FOR
 FINAL INSPECTION FOR C.O. BUT THERE ARE
 SOME ITEMS THAT WERE REQUESTED ON
 PROVISO DATED 8-31-00 WHICH WERE NOT
 DONE.SEE COPY OF PROVISO.
  
 NOTE:
 THERE IS A CHANGE ON THE DESIGN
 PRESSURES FOR GARAGE DOORS. ARCHITECT
 TO SIGN, SEAL AND DATE SUCH REVISION.

Review Stop R ROOF PLAN REVIEW
Rev No 7 Status P Date 2000-10-20 Cont ID  
Sent By jgomez Date 2000-10-20 Time 18:43 Rev Time 0.50
Received By jgomez Date 2000-10-20 Time 18:43 Sent To  
Notes
2001-01-08 00:00:00REVISED ARCHITECT'S ROOF FRAMING PLAN.

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status F Date 2000-10-06 Cont ID  
Sent By jgomez Date 2000-10-05 Time 19:42 Rev Time 1.00
Received By jgomez Date 2000-10-06 Time 10:34 Sent To  
Notes
2001-01-08 00:00:00ARCHITECT'S ROOF FRAMING PLAN REVISION:
  
 1-CONNECTORS SPECIFIED FOR TRUSSES HG-10
 AND SDR-A DON'T WORK. SEE PROFILES OF
 TRUSSES. CLARIFY HOW IS THE SIMPSOM
 HGT2 CONNECTOR SUPPOSED TO BE
 INSTALLED.
 2-SEE TRUSS TGD-1 PROFILE AND CLARIFY
 INSTALLATION OF CONNECTOR SPECIFIED
 ON DETAIL 28/A6.
  
  
  
  
  
 NOTE:
  
 -IF YOU HAVE ANY QUESTIONS PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2000-09-23 Cont ID  
Sent By jgomez Date 2000-09-23 Time 16:14 Rev Time 0.50
Received By jgomez Date 2000-09-23 Time 16:14 Sent To  
Notes
2001-01-08 00:00:00PRODUCT APPROVALS FOR SGD AND FRENCH
 DOORS ARE OK.
  
  
  
 NOTE:
  
 -PLEASE PROVIDE ITEMS REQUESTED ON
 PROVISO DATED 8-31-00 PRIOR TO
 CONSTRUCTION OR INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2000-09-21 Cont ID  
Sent By jgomez Date 2000-09-21 Time 19:21 Rev Time 0.75
Received By jgomez Date 2000-09-21 Time 18:58 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-SHEET A-5 WAS REVISED TO SHOW MISSING
 CONNECTORS AS REQUESTED ON 9-8-00
 CHECKLIST. BUT, NOW THE REVISED SHEET
 DOESN'T SHOW THE CONNECTORS THAT WERE
 ADDED ON 8-23-00. WHY?.
 NOW WE GO BACK TO STEP ONE AGAIN WHERE
 CONNECTORS WERE MISSING. PLEASE AVOID
 UNNECESSARY RETURNS AND DELAYS BY
 CHECKING YOUR MATERIAL PRIOR TO
 SUBMITTAL.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2000-09-08 Cont ID  
Sent By jgomez Date 2000-09-08 Time 10:22 Rev Time 0.75
Received By jgomez Date 2000-09-08 Time 10:22 Sent To  
Notes
2001-01-08 00:00:00ROOF TRUSSES CHECKLIST:
 1-ARCHITECT NEEDS TO REVIEW ALL TRUSS
 DRAWINGS PRIOR TO SUBMITTAL TO THIS
 OFFICE.
 2-ARCHITECT TO SPECIFY CONNECTOR FOR
 GIRDER TRUSS SDR-A AT EAVE END.
 -ARCHITECT TO REVIEW ENGINEERED ROOF
 TRUSSES TO VERIFY THAT CONNECTORS
 SPECIFIED WILL RESIST THE UPLIFT LOADS
 CALCULATED.
  
  
  
 NOTE:
 -IF YOU HAVE ANY QUESTIONS PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-08-31 Cont ID  
Sent By jgomez Date 2000-08-31 Time 14:48 Rev Time 2.50
Received By jgomez Date 2000-08-31 Time 14:47 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE PRODUCT APPROVAL FOR:
 -BUTT GLAZING SYSTEM.
 -CUSTOM MADE KITCHEN WINDOW ASSEMBLY.
 -ENTRY DOORS W/ TRANSOM ABOVE ASSEMBLY.
 -FRENCH DOORS W/ TRANSOM ABOVE ASSEMBLY
 (SEE COMMENTS ON SUBMITTAL).
 -S.G.D. WITH TRANSOM ABOVE ASSEMBLY.
 (SEE COMMENTS ON SUBMITTAL).
 -GARAGE DOORS PRODUCT APPROVALS THAT
 MEET THE DESIGN PRESSURES CALCULATED
 BY THE ARCHITECT.
 2-COMPLETELY SPECIFY CEILING CONSTRUCT'N
 AT ENTRY AND REAR PORCHES, INCLUDING
 FASTENER TYPES AND SPACING. SECTION
 2504 SBC 1997.
 3-STORM PANELS TO BE UNDER A SEPARATE
 PERMIT. (NO INFO. GIVEN AT THIS TIME).
 4-TRUSS DRAWINGS:
 -PROVIDE COMPLETE SET OF ENG'D TRUSS
 DRAWINGS.
 -ENGINEER TO SIGN, SEAL AND DATE TRUSS
 LAYOUT AS WELL.
 -ARCHITECT TO REVIEW ALL TRUSS DRAWINGS
 PRIOR TO SUBMITTAL TO THIS OFFICE.
  
  
  
  
 NOTES:
 -PLEASE SUBMITINFORMATION REQUIRED ON
 PROVISO PRIOR TO CONSTRUCTION OR
 INSTALLATION TO AVOID DELAYS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-08-21 Cont ID  
Sent By jgomez Date 2000-08-21 Time 17:17 Rev Time 4.00
Received By jgomez Date 2000-08-21 Time 17:17 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 PLEASE BRING RECEIPT AND STAMPED DWGS.
 2-PROVIDE TWO COPIES OF SIGNED, SEALED
 AND DATED SURVEY SHOWING THE BUILDING
 LAYOUT.
 3-PROVIDE SAFETY GLASS AS REQUIRED.
 SEE PLANS FOR COMMENTS. SECTION
 2405.2 SBC 1997.
 4-PROVIDE COMPLETE AIR HANDLING UNITS
 HANGING DETAILS.SPECIFY ALL FASTENERS.
 SECTION 104.2.2 CITY AMENDMENTS.
 5-PROVIDE PRODUCT APPROVALS FOR: BUTT
 GLAZING SYSTEM, CUSTOM MADE KITCHEN
 WINDOW, ENTRY DOORS WITH TRANSOM ABOVE
 ASSEMBLY, REAR FRENCH DOORS WITH SIDE-
 LITES AND TRANSOM ABOVE ASSEMBLY,
 SLIDING GLASS DOORS WITH TRANSOM ABOVE
 ASSEMBLY.
 -NOTE: RESUBMIT GARAGE DOORS PRODUCT
 APPROVAL. DOORS DON'T MEET THE DESIGN
 PRESSURES CALCULATED BY ARCHITECT.
 6-REVISE DESIGN CERTIFICATION FOR BLDG
 CODE COMPLIANCE FORM:
 -MEAN ROOF HEIGHT IS + 21'-6", NOT 16"-
 0". MEAN ROOF HEIGHT IS TAKEN FROM
 GRADE, NOT FROM FINISH FLOOR, TO THE
 AVERAGE POINT OF THE HIGHEST ROOF.
 -REVISE THE BASIC VELOCITY PRESSURE
 ACCORDING TO THE MEAN ROOF HEIGHT.
 -CLARIFY WHICH CRITERIA IS USED: ASCE
 7-95 OR SBC 1997. THIS FORM SAYS ASCE
 BUT DRAWING T-1 SAYS SBC 1997.
 -WHERE IS THE IMPORTANCE FACTOR OF
 1.048 TAKEN FROM?.
 -USE CITY FORM ATTACHED.
 7-FOOTING TF88A DOESN'T APPLY TO THE
 SHOWER RECESS. REVISE AS REQUIRED.
 -COLUMN CC824 AT FAMILY ROOM CORNER BET
 SLIDING GLASS DOORS AND BUTT GLAZING
 DOESN'T APPLY. REVISE AS REQUIRED.
 8-COMPLETELY SPECIFY CEILING CONSTRUCT'N
 AT ENTRY AND REAR PORCHES. INCLUDING
 FASTENER TYPES AND SPACING. SECTION
 2504 SBC 1997.
 9-STORM PANELS TO BE SUBMITTED UNDER A
 SEPARATE PERMIT.
 10-TRUSS DRAWINGS:
 -PROVIDECOMPLETE SET OF ENGINEERED
 TRUSS DRAWINGS PRIOR TO MANUFACTURING.
 -ENGINEER TO SIGN, SEAL AND DATE TRUSS
 LAYOUT AS WELL.
 -ARCHITECT TO REVIEW ALL TRUSS DRAWINGS
 PRIOR TO SUBMITTAL TO THIS OFFICE.
 -NOTE: COORDINATE DESIGN CRITERIA AS
 REQUIRED. ARCHITECT IS USING ASCE 7-95
 WITH 145MPH WIND LOAD, WHILE TRUSS
 LAYOUT CALLS FOR SBC 1997 WITH 110 MPH
 WIND LOAD.
 11-SEE PLANS FOR COMMENTS, INCLUDING
 SHEET T-1. ALSO, SEE COMMENTS BY THE
 OTHER TRADES AND REVISE ORIGINAL
 DRAWINGS AS REQUIRED.
 12-WORKERS COMP. IS EXPIRED. PLEASE
 CHECK WITH PEOPLE AT FRONT COUNTER TO
 UPDATE ALL INSURANCE AND LICENSE INFO.
  
 NOTES:
 -PLEASE RETURN REVIEWED SET AFTER ALL
 CORRECTIONS ARE DONE TO ORIGINAL DWGS
 IN ORDER TO EXPEDITE THE REVIEW PROCESS
 -IF YOU HAVE ANY QUESTIONS, PLEASE FEEL
 FREE TO CALL JULIO GOMEZ AT 659-8096
 EXT. 8232.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-07-21 Cont ID  
Sent By gjoyce Date 2000-07-21 Time 08:33 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***