Plan Review Details - Permit 00070781
Plan Review Stops For Permit 00070781
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-09-25 Cont ID  
Sent By hpiskura Date 2000-09-25 Time 08:59 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-08-10 Cont ID  
Sent By hpiskura Date 2000-08-10 Time 14:33 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-09-13 Cont ID  
Sent By dpalmer Date 2000-09-13 Time 20:40 Rev Time 0.00
Received By dpalmer Date 2000-09-13 Time 20:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-08-02 Cont ID  
Sent By dpalmer Date 2000-08-02 Time 20:29 Rev Time 0.00
Received By dpalmer Date 2000-08-02 Time 20:29 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT **************
  
 1)NOTE: PLEASE PROVIDE LOAD CALULATIONS
 SHOWING ALL CONTINUOUS LOADS AT 125%
  
  
 2)NOTE: PLEASE SHOW BATH RECEPTS AS GFI/
 GFI PROTECTED PER 210-8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-10-23 Cont ID  
Sent By mcarsill Date 2000-10-23 Time 08:26 Rev Time 0.00
Received By mcarsill Date 2000-10-23 Time 08:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-08-01 Cont ID  
Sent By mcarsill Date 2000-08-01 Time 10:41 Rev Time 0.00
Received By mcarsill Date   Time   Sent To  
Notes
2001-01-08 00:00:001) DEMOLITION OPERATIONS TO COMPLY WITH
 NFPA 241, THE STANDARD FOR BUILDINGS
 UNDERGOING CONSTRUCTION, ALTERATION AND
 DEMOLITION OPERATIONS.
 2) INTERIOR FINISH ON WALLS AND CEILINGS
 SHALL BE CLASS A OR B.
 3) PROVIDE ILLUMINATED EXIT SIGN AT
 ENTRY LOCATION.
 4) NO FIRE SPRINKLER DRAWINGS INCLUDED
 IN PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-09-06 Cont ID  
Sent By ndenmark Date 2000-09-06 Time 10:38 Rev Time 0.50
Received By ndenmark Date 2000-09-06 Time 10:38 Sent To  
Notes
2001-01-08 00:00:00PRIOR COMMENTS ADDRESSED BY REVISION
 PROVISO: INSULATE TOP OF DIFFUSERS PER
 FLA ENERGY CODE 410.1 ABCD 2.1
 DUCT SMOKE DETECTOR TO BE IN RETURN AIR
 PRIOR TO ANY MIXING OF OUTSIDE AIR

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-07-27 Cont ID  
Sent By ndenmark Date 2000-07-27 Time 11:08 Rev Time 0.33
Received By ndenmark Date 2000-07-27 Time 11:08 Sent To  
Notes
2001-01-08 00:00:00*************DENIED*********************
 1) PROVIDE AIR BALANCE SCHEDULE SHOWING
 COMPLIANCE W/ 1997 SMC 501.2
 2) OUTSIDE AIR APPEARS TO BE 371 CFM,
 EXHAUST AIR IS 900 CFM. SPACE WOULD BE
 529 CFM NEG. PROVIDE SOURCE FOR ADDITION
 TO MAKE UP DIFFERENCE

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-10-18 Cont ID  
Sent By tlarge Date 2000-10-18 Time 13:47 Rev Time 1.50
Received By tlarge Date 2000-10-18 Time 12:03 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
 1)DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).PROVISIONS SHALL BE
 MADE FOR PEOPLE WHO HAVE TROUBLE BENDING
 OR STOOPING.
  
 2)FLOORS AND WALLS IN TOILET ROOMS SHALL
 BE NON ABSORBENT TO A HEIGHT OF 4' PER
 SBC SEC.1204.2.
  
 CALL IF YOU HAVE QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER
 561-659-8096,EXT.8377.

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-09-27 Cont ID  
Sent By tlarge Date 2000-09-27 Time 16:19 Rev Time 1.25
Received By tlarge Date 2000-09-27 Time 16:19 Sent To  
Notes
2001-01-08 00:00:001)WALL FINISH IN TOILET ROOM SHALL BE
 NONABSORBENT TO A HEIGHT OF 4"PER SBC
 SEC.1204.2.
  
 2)PROVISIONS SHALL BE MADE AT THE DRINK-
 ING FOUNTAIN FOR PEOPLE WHO HAVE TROUBLE
 BENDING OR STOOPING.FACBC SEC.4.1.3.(10)
 (A).
  
 3)SUBMIT INFORMATION/MANUF.SHEETS FOR
 THE SILVER RECOVERY SYSTEM.DATA IS REQD.
 REGARDING THE PH OF THE EFFLUENT AND THE
 DISCHARGE OF THE WASTE.CLEARLY SHOW HOW
 WASTE IS REMOVED.IF TO THE SANITARY A
 NEUTRALIZATION TANK MAY BE REQD.
 ADDITIONAL REQS.MAY BE MANDATED BY CITY
 OF WPB UTILITIES DEPT.CONTACT ROD COMPO
 AT 561-835-7423.
  
 4)SHT.E-2-EWH STILL NOTED AS "SUSPENDED
 FROM STRUCTURE."SUPPLY SHIP'S LADDER
 AND PLATFORM OR RELOCATE TO FLOOR.SPC
 SEC.501.7.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-08-27 Cont ID  
Sent By tlarge Date 2000-08-27 Time 09:35 Rev Time 1.00
Received By tlarge Date 2000-08-27 Time 09:03 Sent To  
Notes
2001-01-08 00:00:001)WALL FINISH IN TOILET ROOM SHALL BE
 NONABSORBENT TO A HEIGHT OF 4'PER SBC
 SEC.1204.2.(INDICATE TYPE OF PAINT)
  
 2)A DRINKING FOUNTAIN IS REQD.PER SPC
 TABLE 407.FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).PROVISIONS SHALL BE
 MADE FOR PEOPLE WHO HAVE TROUBLE BENDING
 OR STOOPING.
  
 3)SHT.M-2 NOTES RELIEF AND PAN DRAIN TO
 FLOOR SINK.SINK IS ON RISER BUT NOT ON
 FLOOR PLAN.CLARIFY.
  
 4)HEATER SHALL BE EQUIPPED W/HEAT TRAPS
 PER FLA.ENERGY CODE.
  
 5)HUB DRAINS NOT PERMITTED.FLOOR SINK
 REQD.PER SPC SEC.807.1.
  
 6)SUBMIT INFORMATION /MANUF.SHEETS FOR
 THE SILVER RECOVERY SYSTEM.DATA REQD.
 REGARDING THE PH OF THE EFFLUENT AND
 THE DISCHARGE OF THE WASTE.CLEARLY SHOW
 HOW WASTE IS REMOVED.IF TO THE SANITARY
 A NEUTRALIZATION TANK MAY BE REQD.
 CONTACT R.COMPO AT CITY OF WPB WASTE-
 WATER TREATMENT FACILITY FOR APPROVAL.
 561-835-7423.
  
 7)SHT.M02 AND E-2 STILL NOTE THE EWH AS
 BEING IN THE CEILING.COMPLY W/SPC 501.7.
  
 CALL(561)659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-08-05 Cont ID  
Sent By pschmitz Date 2000-08-05 Time 11:34 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLUMBING PLAN PROVISO:
 SEE SHT M-2 FOR CONDITIONS OF APPROVAL.
 END OF COMMENTS, PES