| Plan Review Stops For Permit 00070765 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2001-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-04 |
Time |
19:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-04 |
Time |
19:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2001-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-03 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-03 |
Time |
18:33 |
Sent To |
|
|
| Notes |
| 2001-04-03 00:00:00 | **************UNSAT *************** | | | | | | NOTE: PLEASE NOTE THAT SINCE DEC,13,2000 | | | NO ONE HAS COME IN FOR AN ELECTRICAL | | | PERMIT. | | | PLEASE CALL THIS OFFICE TO CLEAR THIS MA | | | TTER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-13 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-13 |
Time |
19:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLANS ARE STILL NOT CORRECT?? | | | SMOKE DETECTORS ARE REQ`D INSIDE AND | | | OUTSIDE ALL SLEEPING ROOM PER NFPA-72 | | | 2-2.1.1.1 NONE SHOWN ON PLANS ???? | | | ALSO ON EACH LEVEL. | | | 2)NOTE: PLEASE SEE E-1 SHOWS ELEVATOR | | | AND NOTES TO RISER? THE RISER SHOWS | | | EL 2P. IS THIS THE SAME THING? ALSO THE | | | PANEL SCHEDULE THAT FEEDS EL-2P DOESNOT | | | SHOW ELEVATOR? PLEASE CLARIFY. | | | | | | 3)NOTE: PLEASE NOTE THAT ON 9/20/00 IT | | | WAS REQ`STED BY THE CONTRACTOR TO THE | | | BLDG PLAN REVIEWER AND MYSELF THAT THE | | | PERMIT BE ISSUED WITHOUT THE ELECTRICAL | | | BEING APPROVED. SEPARATE APPLICATION | | | AND PLANS WERE REQ`D FOR ELEC. | | | ON 11/21/00 A MISC ELEC DEMO PERMIT WAS | | | ISSUED TO ELEC CONTRACTOR BECAUSE HE DID | | | NOT HAVE PLANS. ONLY MISC ELEC DEMO!!! | | | PLEASEHAVE ELECTRICAL CONTRACTOR | | | SUBMIT CORRECTED PLAN WITH HIS PERMIT | | | APPLICATION. | | | | | | 4)NOTE: PLEASE SEE PLANS E-2 SERVICE | | | CALCS SHOW LOAD AT 236AMPS. A NEW GUTTER | | | IS SHOWN BUT NO NEW SERVICE CONDUCTORS?? | | | OR METERCAN AND SIZE. | | | | | | 5)NOTE: PLANS ARE NOW SHOWING THE NEW | | | EQUIPMENT AND NO AIC RATINGS??PER 110-9 | | | AND 215-5 | | | | | | | | | 6)NOTE: PLEASE NOTE THAT COMPLETE AS- | | | -BUILTS AND PANEL SCHEDULES ARE REQ`D | | | BEFORE FINAL ELECTRICAL INSPECTION. | | | | | | 7)NOTE: PLEASE SEE NOTES FORM OTHER | | | REVIEWS. PANEL "B" SHOWN IN CLOSET. | | | THE PANEL WILL HAVE TO BE MOVED OR THIS | | | ROOM WOULD HAVE TO BE DEDICATED FOR | | | ELECTRICAL/ EQUIPMENT. SEE 384-7 | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-20 |
Time |
14:08 |
Rev Time |
0.15 |
| Received By |
dpalmer |
Date |
2000-09-20 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CONTRACTOR TO APPLY FOR A SEPARATE | | | PERMIT. 9-20-00. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-19 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-19 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | | | | 1)NOTE: AS PER CONVERSATION WITH THE | | | ENGINEER MR. CHANE. THE ITEMS WE WENT | | | OVER WERE NOT ADDRESSED AND CHANGES WERE | | | NOT MADE ON THE PLANS. | | | | | | 2)NOTE: PLEASE SEE 384-7 FOR PANEL "B" | | | SHOWN ON E-3 | | | | | | 3)NOTE: UPON REVIEW OF PLANS THE SECOND | | | TIME. MORE THAN 50% OF THE WIRING SHOWN | | | NEW ON PLANS. PLEASE NOTE OUTLET SPACING | | | TO BE BROUGHT UP TO CODE. 210-52 | | | | | | PLEASE HAVE ENGINEER CALL TO SET UP A | | | MEETING WITH PLAN REVIEWERS TO CLEAR UP | | | ALL COMMENTS IN PERSON. | | | PLEASE CALL | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-01 |
Time |
16:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-01 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ****************** | | | | | | PLEASE NOTE THAT MORE THAN 50% OF THE | | | ELECTRICAL WORK IS BEING DONE. PLEASE | | | NOTE :ALL ELECTRICAL WILL HAVE TO BE | | | BROUGHT UP TO CODE. | | | | | | 1)NOTE: PLEASE SHOW ALL EXISTING AND | | | NEW MEAMS OF EGRESS LIGHTING PER 210-70 | | | | | | 2)NOTE: SMOKE DETECTORS WILL BE REQ`D | | | PER NFPA-72 2-2.1.1.1 INSIDE AND OUTSIDE | | | ALL SLEEPING ROOMS. AND EACH LEVEL OF | | | MULTI-LEVEL DWELLING. | | | | | | 3)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED. 210-8-A-6 | | | | | | 4)NOTE: PLEASE SUBMIT PANEL SCHEDULES | | | PLEASE SHOW PANEL "D" MCB . YOU SAY IT | | | IS BEING FED BY 100 MCB ?? WHERE IS THIS | | | E-3 SHOWS PANEL B?? WHERE IS THIS ON | | | RISER DIADGRAM. | | | | | | 5)NOTE: PLEASE SHOW LOCATION OF ALL | | | EQUIPMENT/PANELS/MAINS ETC. | | | MAINS MUST BE GROUPED PER 230-72 | | | PLEASE GIVE CLARIFICATION ON SERVICE | | | ENTRANCE CONDUCTORS. COPPER/ALUM? | | | YOU SHOW LOAD AT 222 AMPS AND NO ROOM | | | FOR SPARE LOAD.PLEASE SHOW LOADS ON EACH | | | PANEL. | | | | | | 6)NOTE: PLEASE SHOW EXISTING ELECTRICAL | | | OUTLETS ETC.SPACING SHALL BE BROUGHT UP | | | TO CODE. PER 210-52 | | | 7)NOTE: PLEASE SHOW EXISTING GROUNDING | | | ELECTRODE SYSTEM.215-5 | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-03-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-28 |
Time |
08:44 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-03-28 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2001-03-28 00:00:00 | NO REVISIONS TO MECHANICAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-08 |
Time |
14:51 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-12-08 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-20 |
Time |
14:06 |
Rev Time |
0.15 |
| Received By |
jgomez |
Date |
2000-09-20 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CONTRACTOR WILL APPLY FOR A SEPARATE | | | PERMIT. 9-20-00 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-28 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-28 |
Time |
15:33 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-28 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | CFM VALUE OF EACH SUPPLY DROP TO BE SUB- | | | MITTED BEFORE INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-04-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-04-02 |
Time |
13:54 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-04-02 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-08 |
Time |
14:52 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-12-08 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-20 |
Time |
14:21 |
Rev Time |
0.15 |
| Received By |
jgomez |
Date |
2000-09-20 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CONTRACTOR TO APPLY FOR SEPARATE PERMIT | | | 9-20-00. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-08-01 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-01 |
Time |
09:48 |
Rev Time |
0.65 |
| Received By |
tlarge |
Date |
2000-08-01 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SHT.M-2-PLANS SHOW GAS WATER HEATER IN | | | CLOSET.GAS WATER HEATER CANNOT BE LOCAT- | | | ED IN CLOSET PER SGC SEC.504.1.SEE | | | "EXCEPTION" FOR INSTALLATION REQS.AND | | | SUBMIT CALCULATIONS FOR COMBUSTION AIR. | | | COMPLY W/SGC SEC.402.4.` |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
7 |
Status |
P |
Date |
2001-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-05-21 |
Time |
18:50 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2001-05-21 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2001-05-21 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-MINIMUM HEADROOM AT STAIRS TO BE | | | 6'-8". SECTION 1007.7 SBC 1997. | | | VERIFY IN FIELD THE HEADROOM BY | | | EXISTING BEAM. | | | | | | 2-PROVIDE COMPLETE SHOP DRAWINGS FOR | | | RAILINGS. | | | -PROFESSIONAL OF RECORD TO REVIEW ALL | | | SHOP DRAWINGS PRIOR TO SUBMITTAL TO | | | THIS OFFICE. | | | | | | 3-NEED TO PROVIDE SMOKE DETECTORS AT | | | EACH STORY AS REQUIRED BY SECTION | | | 905.2.2 SBC 1997. | | | | | | 4-PROVIDE COMPLETE STRUCTURAL BUCK | | | DETAIL TO RESIST THE LOADS IMPOSSED | | | BY THE GARAGE DOOR. SECTION 104.2.2 | | | CITY AMENDMENTS TO SBC 1997. | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 659-8096 EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
6 |
Status |
F |
Date |
2001-04-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-04-12 |
Time |
11:06 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2001-04-11 |
Time |
19:21 |
Sent To |
|
|
| Notes |
| 2001-04-12 00:00:00 | SECOND CHECKLIST TO REVISIONS: | | | 1-PROVIDE REVISED ENERGY CALCULATIONS | | | TO REFLECT REVISIONS (NO DONE FROM | | | CHECKLIST DATED 12-18-00). | | | 2-CEILING FANS: | | | -ENGINEER TO REVIEW TABLE 6-6 FLORIDA | | | ENERGY EFFICIENCY CODE FOR BUILDING | | | CONSTRUCTION, 1997 EDITION AND THEN | | | CLEARLY INDICATE NUMBER, SIZE AND | | | LOCATION OF CEILING FANS (NOT DONE | | | FROM PREVIOUS CHECKLIST). | | | 3-SECTION THRU NEW STAIRS: | | | -IT IS NOT CLEAR IF STAIRS PROVIDE THE | | | 6'-8" HEADROOM CLEARANCE BY EXISTING | | | BEAM AREA. IF DRAWINGS ARE DONE TO | | | SCALE HOW COME HEADROOM MEASURES 6'-4" | | | BUT THE DIMENSION CALLED IS 6'-11". | | | VERIFY IN FIELD ACTUAL HEIGHT OF BOTT. | | | OF BEAM TO VERIFY HEADROOM. | | | -PROVIDE COMPLETE INFORMATION REGARDING | | | RAILINGS AND GUARDRAILS AS REQUIRED ON | | | SECTION 1007 SBC 1997 (THIS INFO. WAS | | | REQUESTED ON PROVISO DATED 9-20-00 BUT | | | WAS NEVER PROVIDED) | | | 4-PROVIDE LANDING AS REQUIRED AT STEPS | | | AT REAR SIDE OF THE HOUSE AS | | | REQUIRED BY SECTION 1012.1.6 SBC 1997. | | | 5-SPECIFY SMOKE DETECTORS AT EACH STORY | | | AS REQUIRED BY SEC. 905.2.2 SBC 1997. | | | 6-PROVIDE PRODUCT APPROVAL FOR GARAGE | | | DOOR. (GARAGE DOOR WAS NOT PART OF THE | | | SCOPE OF WORK ON ORIGINAL APPLICATION) | | | 7-CONTRACTOR NEEDS TO UPDATE INSURANCE. | | | IT EXPIRED ON 2-20-01. | | | 8-PAY $7.50 ADDITIONAL RADON FEE FOR | | | REVISED ADDITIONAL AREA. SEE RECEIPT. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 659-8096 EXT. 8232. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-12-19 |
Time |
08:57 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2000-12-18 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | | | | 1-ARCHITECT DIDN'T SIGN, SEAL AND DATED | | | THE DRAWINGS. CHAPTER 481 FL. STATUTES | | | | | | 2-PROVIDE REVISED ENERGY CALCULATIONS. | | | | | | 3-NEW ELEVATOR: | | | -PROVIDE COMPLETE SECTION DETAIL THRU | | | ELEVATOR SHAFT. SECTION 104.2.2 OF | | | CITY AMENDMENTS TO SBC 1997. | | | -PROVIDE COMPLETE SPECIFICATIONS FOR | | | ELEVATOR CONFORMING TO ANSI/ASME A17.1 | | | | | | 4-SPECIFY NUMBER OF CEILING FANS AS | | | REQUIRED BY TABLE 6-6 FLORIDA ENERGY | | | EFFICIENCY CODE FOR BUILDING CONST., | | | 1997 EDITION. SEE COMMENTS ON PLANS. | | | | | | 5-CORRECT AREA TABULATIONS AS REQUIRED | | | WITH NEW ENCLOSED AREA. SEE SHEET R1. | | | | | | 6-SECOND FLOOR WINDOWS AT MASTER BEDRM | | | DON'T COMPLY WITH EGRESS REQUIREMENTS | | | SECTION 1005.4.4 SBC 1997. REVISE | | | WINDOW SCHEDULE AS REQUIRED. | | | | | | 7-SEE COMMENTS ON PLANS. INCLUDING | | | COMMENTS BY THE OTHER TRADES. | | | | | | 8-SECTION THRU NEW STAIRS SHOW HEADROOM | | | CLEARANCE OF 6'-3" +/-.IT IS NOT | | | ALLOWED. MIN. HEADROOM CLEARANCE IS | | | 6'-8" AS PER SECTION 1007.7 SBC 1997. | | | REVISE STAIRS AS REQUIRED. | | | | | | 9-NEED TO OBTAIN A PERMIT FOR MECHANICAL | | | WORK. THERE IS NONE APPLIED FOR. | | | | | | 10-ADDITIONAL FEES OF $101.00 ARE DUE | | | FOR REVISION UPGRADES. ADDITIONAL | | | CONSTRUCTION. | | | | | | | | | NOTES: | | | -IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 659-8096 EXT. 8232. | | | -PLEASE RETURN REVIEWED SET AFTER | | | CORRECTIONS ARE DONE TO ORIGINAL DWGS | | | IN ORDER TO EXPEDITE THE REVIEW. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2000-09-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-20 |
Time |
12:09 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2000-09-20 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-STAIRWAY CONSTRUCTION: | | | -REVISE STRUCTURAL DRAWINGS TO MATCH | | | ARCHITECT'S NEW LAYOUT. | | | -PROVIDE COMPLETE INFORMATION REGARDING | | | CONSTRUCTION OF RAILINGS & GUARDRAILS. | | | 2-REVISE ALL ORIGINAL DRAWINGS AS REQ'D. | | | SEE COMMENTS ON PLANS. INCLUDING THOSE | | | BY THE OTHER TRADES. | | | 3-EGRESS WINDOWS AT MASTER BEDROOM NEED | | | TO BE REVISED. (2)17X47 CASEMENT | | | WINDOWS DON'T PROVIDE THE MINIMUM | | | WIDTH REQUIRED. SEC. 1005.4.4 SBC 1997 | | | (THERE'S A MULLION IN BETWEEN). | | | 4-ROOFING, MECHANICAL, ELECTRICAL AND | | | PLUMBING CONTRACTORS NEED TO APPLY FOR | | | THEIR OWN PERMIT. REFERENCE THIS | | | PERMIT APPLICATION NUMBER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2000-09-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-19 |
Time |
17:20 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2000-09-19 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST | | | 1-STAIRWAY CONSTRUCTION: | | | -REVISE STRUCTURAL DRAWINGS TO MATCH | | | ARCHITECT'S NEW LAYOUT, WHICH COMPLIES | | | WITH SECTION 1007 SBC 1997. | | | -PROVIDE COMPLETE INFORMATION REGARDING | | | RAILINGS AND GUARDRAILS CONSTRUCTION | | | AND DESIGN. | | | 2-REVISE ALL ORIGINAL DRAWINGS AS REQ'D | | | SEE COMMENTS ON PLANS. INCLUDING THOSE | | | BY THE OTHER TRADES. | | | 3-EGRESS WINDOWS AT MASTER BEDROOM NEED | | | TO BE REVISED. (2)17X47 CASEMENT | | | WINDOWS DON'T PROVIDE THE MINIMUM | | | WITH REQUIRED. SEC. 1005.4.4 SBC 1997. | | | (THERE IS A MULLION IN BETWEEN WIND'S) | | | | | | | | | | | | NOTES: | | | -CONTRACTOR NEEDS TO UPDATE LICENSE. | | | -ELECTRICAL, MECHANICAL, PLUMBING AND | | | ROOFING CONTRACTORS DIDN'T SIGN THE | | | PERMIT APPLICATION. THEREFORE, THEY | | | NEED TO APPLY FOR THEIR OWN PERMIT. | | | -BUILDING REVIEW WAS APPROVED WITH A | | | PROVISO. BUT, SINCE NOT REVISIONS WERE | | | DONE TO THE ELECTRICAL AND PLUMBING | | | PLANS, THEN, THEY WERE DENIED AGAIN. | | | SO, IN ORDER TO EXPEDITE AND FACILITATE | | | THE REVIEW PROCESS, IT IS RECOMMENDED | | | TO REVISE ALL ORIGINAL DRAWINGS AND | | | RE-SUBMIT A COMPLETE PACKAGE FOR ALL | | | THE TRADES INVOLVED. | | | | | | -IMPORTANT: PLEASE RETURN REVIEWED SETS | | | AFTER CORRECTIONS ARE DONE IN ORDER TO | | | EXPEDITE THE REVIEW PROCESS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-09-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-09-14 |
Time |
21:17 |
Rev Time |
3.50 |
| Received By |
jgomez |
Date |
2000-09-14 |
Time |
21:16 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | | | | 1-STAIRWAY CONSTRUCTION: | | | -REVISE STRUCTURAL DRAWINGS TO MATCH | | | ARCHITECT'S LAYOUT. | | | -PROVIDE COMPLETE CONSTRUCTION INFO. | | | REGARDING THE RAILINGS AND GUARDRAILS. | | | | | | 2-REVISE ALL ORIGINAL DRAWINGS AS REQ'D | | | SEE COOMENTS ON PLANS. | | | 3-EGRESS WINDOWS AT MASTER BEDROOM NEED | | | TO BE REVISED. (2)17X47 WINDOWS DON'T | | | PROVIDE THE MIN. WIDTH. SEC 1005.4.4. | | | | | | NOTES: | | | -PROVIDE INFORMATION REQUESTED PRIOR TO | | | ANY INSPECTIONS. | | | -CONTRACTOR NEEDS TO UPDATE LICENSE. | | | -ELECTRICAL, MECHANICAL, PLUMBING AND | | | ROOFING CONTRACTORS DIDN'T SIGN THE | | | APPLICATION. THEREFORE, THEY NEED TO | | | APPLY FOR THEIR OWN PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-08-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2000-08-16 |
Time |
16:54 |
Rev Time |
3.50 |
| Received By |
jgomez |
Date |
2000-08-16 |
Time |
16:54 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CHECKLIST: | | | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. | | | BRING STAMPED DRAWINGS AND RECEIPT. | | | 2-SITE PLAN INDICATES SOME WORK TO BE | | | DONE ON THE SIDEWALK. COORDINATE WITH | | | THE ENGINEERING DEPT. FOR SPECIFIC | | | REQUIREMENTS PRIOR TO ANY CONSTRUCTION | | | AT 659-8040. BET. 7:00 AM TO 3:00 PM. | | | 3-CLEARLY INDICATE ON PLANS WHAT'S NEW, | | | WHAT IS EXISTING. WHAT IS GOING TO BE | | | REPLACED, ETC. | | | -PROVIDE MORE DIMENSIONS. EG OPENING | | | DIMENSIONS, ETC | | | -PROVIDE COMPLETE DOOR AND WINDOW SCHED | | | 4-REVISE ENERGY CALCULATIONS AS REQUIRED | | | -SCOPE OF WORK IS NOT ONLY THE ADDITION | | | ON SECOND FLOOR, BUT THE WHOLE HOUSE | | | IS GOING TO BE CONSIDERABLY RENOVATED. | | | SEC. 600.1.C.1 AND 600.1.C.2 FLORIDA | | | ENERGY EFFICIENCY CODE FOR BUILDING | | | CONSTRUCTION. | | | -OWNER TO SIGN AND DATE THIS FORM TOO. | | | 5-REVISE DESIGN CERTIFICATION FOR BLDG | | | CODE COMPLIANCE FORM:(STRUCTUR'L ENGR) | | | -THIS IS A TWO STORY HOUSE. MEAN ROOF | | | HEIGHT IS 24'-8" PLUS OR MINUS. REVISE | | | THE BASIC VELOCITY PRESSURE AS REQ'D | | | 6-MASTER BEDROOM AND BEDROOMS #1 AND #2: | | | -MUST MEET EGRESS REQUIREMENTS AS PER | | | SECTION 1005.4.4 SBC 1997. | | | 7-AT LEAST ONE COMPLETE BATHROOM ON 1ST | | | FLOOR MUST HAVE A DOOR THAT PROVIDES | | | 29" MINIMUM CLEAR OPENING. SECTION 11 | | | FLORIDA ACCESSIBILITY CODE FOR BLDG. | | | CONSTRUCTION, 1997 EDITION. | | | 8-STORM PANELS: | | | -PROVIDE A COMPLETE INSTALLATION SCHED. | | | AS PER CITY SAMPLE ATTACHED AND A | | | COMPLETE KEY PLAN. | | | -PROVIDE A COMPLETE CURRENT PRODUCT | | | APPROVAL REPORT AND DRAWINGS AND | | | HIGHLIGHT SPECIFIC MOUNTING CONDITIONS | | | AND ANCHORS TO BE USED ACCORDING TO | | | THE MEAN ROOF HEIGHT,DESIGN PRESSURES, | | | PANEL SPAN, EDGE DISTANCE AND | | | STRUCTURE TO BE ATTACHED TO (CONCRETE | | | OR CONCRETE BLOCK). | | | 9-SPECIFY THE DESIGN PRESSURES THAT | | | WERE CALCULATED AT ALL EXTERIOR | | | OPENINGS. SECTION 1606 SBC 1997. | | | 10-NEW STAIR CONSTRUCTION: | | | -NEED MORE INFORMATION LIKE DIMENSIONS, | | | RISER TREAD RATIO, RAILINGS ECT. | | | SEE SECTION 1007 SBC 1997. | | | -STAIRS NEED TO BE REVISE TO COMPLY W/ | | | THE FOLLOWING SECTIONS: 1007.6.2 - | | | 1007.6.3 - 1007.7 - 1007.8.1 OF SBC/97 | | | 11-PROVIDE SAFETY GLASS AT LIVING ROOM | | | AND MASTER BATHRM. SEC 2405.2 SBC 1997 | | | 12-PROVIDE CURRENT PRODUCT APPROVALS FOR | | | FLAT ROOF SYSTEM AND BARREL TILE | | | (CLEARLY INDICATE SYSTEM AND FASTENING | | | TO BE USED). | | | 13-WINDOWS & DOORS SITE SPECIFIC PRODUCT | | | APPROVALS: | | | -ENGINEER WHO SIGNED ITEM #10 IS NOT | | | THE PROFESSIONAL ENGINEER OF RECORD. | | | -ITEMS #9 AND #10: ENGINEERS TO CLEARLY | | | PROVIDE NAME, LICENSE NUMBER AND | | | ADDRESS AS PER CHAPTER 471 OF FLORIDA | | | STATUTES. | | | -CLARIFY WHY ITEM #4.1.E.IV DOES NOT | | | CONSIDER THE BUCK TO BE STRUCTURAL IF | | | THE SPECIFIC INSTALLATION REQUIREMENTS | | | SPECIFIES ATTACHMENT OF WINDOW OR DOOR | | | TO THIS BUCK. | | | -CLEARLY SPECIFY MODEL | | | 14-PROVIDE HANDRAILS AT STEPS LEADING | | | TO POOL DECK. SEC 1007.5 SBC 1997. | | | 15-CLEARLY SPECIFY SIZES OF CEILING FANS | | | AS PER TABLE 6-6 OF FLORIDA ENERGY | | | EFFICIENCY CODE FOR BUILDING | | | CONSTRUCTION, 1997 EDITION. | | | 16-SEE PLANS FOR ADDITIONAL COMMENTS, | | | INCLUDING THOSE BY THE OTHER TRADES. | | | 17-UPDATE SOIL TEST REPORT. WE ADOPTED | | | THE 1997 SBC. SEE SHEET #1 OF REPORT. | | | | | | | | | | | | | | | NOTE: | | | | | | PLEASE RETURN REVIEWED SETS AFTER ALL | | | REVISIONS/CORRECTIONS ARE DONE IN ORDER | | | TO EXPEDITE THE REVIEW PROCESS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-04-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-04-11 |
Time |
14:43 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-09-18 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-07-25 |
Time |
07:50 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 12' WALL NOT ALLOWED |
|
|