Plan Review Details - Permit 00070560
Plan Review Stops For Permit 00070560
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-07-28 Cont ID  
Sent By dpalmer Date 2000-07-28 Time 06:07 Rev Time 0.00
Received By dpalmer Date 2000-07-28 Time 06:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-08-07 Cont ID  
Sent By cthirben Date 2000-08-07 Time 12:56 Rev Time 1.00
Received By cthirben Date 2000-08-07 Time 12:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-07-28 Cont ID  
Sent By cthirben Date 2000-07-28 Time 09:00 Rev Time 1.00
Received By cthirben Date 2000-07-28 Time 09:00 Sent To  
Notes
2001-01-08 00:00:00DENIED:
 ADDITIONAL 190 CFM TO BE SUPPLIED BU AHU
 SUBMIT INFO TO VERIFY.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-07-28 Cont ID  
Sent By tlarge Date 2000-07-28 Time 07:14 Rev Time 0.33
Received By tlarge Date 2000-07-28 Time 07:14 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-08-26 Cont ID  
Sent By jgomez Date 2000-08-26 Time 14:24 Rev Time 1.50
Received By jgomez Date 2000-08-26 Time 14:24 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS:
 -INFORMATION SUBMITTED IS MISSING THE
 APPROVED DRAWINGS REFERENCED IN THE
 PRODUCT APPROVAL.
 -INSTALLATION SCHEDULE AND KEY PLAN
 DON'T MATCH. SEE FLOOR PLAN.
 -INFORMATION GIVEN IN THE INSTALLATION
 SCHEDULE IS NOT CLEAR. EG: SPECIFIC
 ANCHOR TO BE USED ACCORDING TO THE
 STRUCTURE TO BE ATTACHED TO (MASONRY
 OR WOOD). SHUTTER SPAN (VERTICAL OR
 HORIZONTAL.
 2-EGRESS WINDOWS TO HAVE 24" MINIMUM
 CLEAR HEIGHT OPENING AS PER SECTION
 1005.4.4 SBC 1997.
 NOTE: TO BE FIELD VERIFIED AFTER
 WINDOW INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-08-18 Cont ID  
Sent By jgomez Date 2000-08-18 Time 14:40 Rev Time 1.50
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00SECOND CHECKLIST:
 1-BEDROOM WINDOWS DON'T COMPLY WITH THE
 MINIMUM EGRESS REQUIREMENTS OF SECTION
 1005.4.4 OF SBC 1997. A 24 SINGLE HUNG
 WINDOW DOESN'T PROVIDE 24" MINIMUM
 CLEAR HEIGHT OPENING. ALSO,PGT DOESN'T
 HAVE ANY 4'-4" HIGH WINDOW AS SHOWN ON
 ARCHITECT'S DRAWINGS.
 REVISE DRAWINGS AS REQUIRED.
 2-STORM PANELS:
 -PROVIDE KEY PLAN INDICATING WINDOWS OR
 DOORS TO RECEIVE STORM PANELS.
 -CLEARLY INDICATE TYPE OF CONSTRUCTION
 TO RECEIVE STORM PANELS. WOOD OR
 CONCRETE BLOCK BECAUSE ANCHOR TYPE AND
 SPACING IS DIFFERENT.
 -ALSO TAKE INTO CONSIDERATION THAT
 ANCHOR SELECTED IS TO BE EMBEDED INTO
 THE CONCRETE BLOCK OR WOOD. ANCHORS
 ARE NOT GOOD TO BE ATTACHED TO BRICK.
 -CLEARLY SPECIFY ANCHOR TYPE IN THE
 INSTALLATION SCHEDULE. ALSO, REVISE
 THE SHUTTER SPAN.
 -PROVIDE COPIES OF THE APPROVED DWGS AS
 SPECIFIED ON THE PRODUCT APPROVAL
 REPORT AND HIGHLIGHT SPECIFIC MOUNTING
 CONDITIONS AND ANCHOR TYPE AND SPACING
 TO BE USED.
 3-REVISE ENERGY CALCULATIONS:
 -PREDOMINANT EAVE OVERHANG IS NOT 2'-0"
 SEE EXTERIOR ELEVATIONS.
 -COMPLETELY FILL TABLE 6C-2.
 -SEE GENERAL DIRECTIONS AT THE BOTTOM
 OF PAGE TWO.
 -USE THE UPDATED BLANK SHEETS ATTACHED
 -TABLE 6C-3: CHECK ONLY THE ITEMS THAT
 APPLY TO THIS PROJECT.
 -OWNER TO SIGN AND DATE THIS FORM ALSO.
 4-PROVIDE PRODUCT APPROVAL FOR WINDOW
 MULLIONS.
 -PROVIDE PRODUCT APPROVAL WITH LEGIBLE
 DRAWINGS FOR FRENCH DOOR WITH SIDELITE
 AND SINGLE HUNG WINDOWS.
  
  
  
  
  
  
  
 NOTES:
  
 -PLEASE CALL JULIO GOMEZ AT 659-8096 EXT
 8232 IF YOU HAVE ANY QUESTIONS.
 -PLEASE RETURN REVIEWED SET AFTER ALL
 REVISIONS ARE DONE IN THE ORIGINAL
 DRAWINGS IN ORDER TO EXPEDITE THE
 REVIEW PROCESS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-08-09 Cont ID  
Sent By jgomez Date 2000-08-09 Time 18:43 Rev Time 2.50
Received By jgomez Date 2000-08-09 Time 18:43 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 2-SURVEY TO BE SIGNED, SEALED AND DATED,
 FOR PUBLIC RECORD. CHAPTER 471 FLORIDA
 STATUTES.
 3-STORM PANELS:
 -PROVIDE COMPLETE PRODUCT APPROVAL,
 INCLUDING APPROVED DRAWINGS.
 -PROVIDE COMPLETE INSTALLATION SCHEDULE
 AS PER CITY SAMPLE ATTACHED AND KEY
 PLAN.
 -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS
 AND ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO STRUCTURE TO BE ATTACHED
 TO.
 4-ARCHITECT TO PROVIDE FRAMING DETAILS
 FOR DOORS AND WINDOWS SHOWING HOW ARE
 OPENINGS PREPARED TO RECEIVE STORM
 PANELS. SEC. 104.2.2 CITY AMENDMENTS.
 5-PROVIDE ENERGY CALCULATIONS AS PER
 FLORIDA ENERGY CODE FOR BUILDING
 CONSTRUCTION REQUIREMENTS. 1997 ED.
 6-ARCHITECT TO SHOW ON PLANS HOW IS THE
 ADDITION COMPLYING WITH THE FLORIDA
 ENERGY CODE. EG: INSULATION OF ALL
 EXTERIOR WALLS -EXISTING AND NEW. INFO
 MUST MATCH ENERGY CALCULATIONS.
 7-ARCHITECT TO PROVIDE COMPLETE LAYOUT
 IDENTIFYING ALL ROOMS INVOLVED IN THE
 RENOVATION.
 I NEED THIS INFORMATION TO CHECK THAT
 BEDROOMS WILL HAVE WINDOWS THAT COMPLY
 WITH SECTION 1005.4.4 OF SBC 1997 FOR
 EGRESS REQUIREMENTS.
 8-DESIGN CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM:
 -PROVIDE UPDATED FORM. SEE ATTACHED.
 -FILL IN ALL THE NECESSARY INFORMATION
 INCLUDING ADDRESS.
 -WHERE IS BASIC VELOCITY TAKEN FROM?.
 SEE TABLE 1606.2A SBC 1997. SEE
 RELATIONSHIP BETWEEN BASIC VELOCITY
 AND MEAN ROOF HEIGHT.
 -CLARIFY WHY ROOF DEAD LOAD IS 55PSF.
 9-PRODUCT APPROVALS:
 -PROVIDE PRODUCT APPROVAL FOR DOUBLE
 FRENCH DOORS AND FRENCH DOOR WITH
 SIDELITE ASSEMBLY.
 -PROVIDE COMPLETE PRODUCT APPROVAL FOR
 SINGLE HUNG WINDOWS, INCLUDING THE
 APPROVED DRAWINGS.
 SPECIFY WHAT TYPE OF WINDOWS ARE GOING
 TO BE USED, IMPACT OR NON-IMPACT.
 10-SEE PLANS FOR COMMENTS, INCLUDING
 COMMENTS BY THE OTHER TRADES.
  
  
  
  
  
  
 NOTES:
 -PLEASE RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE IN ORIGINAL DWGS
 IN ORDER TO EXPEDITE THE REVIEW PROCESS
 -IF YOU HAVE ANY QUESTIONS OR COMMENTS,
 PLEASE FEEL FREE TO CALL JULIO GOMEZ AT
 659-8096 EXT. 8232.
  
  
 PS: UNABLE TO CALL OWNER. THERE ARE NOT
 TELEPHONE NUMBERS ON APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-07-25 Cont ID  
Sent By gjoyce Date 2000-07-25 Time 07:16 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***