| Plan Review Stops For Permit 00070350 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2000-09-11 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-09-11 |
Time |
09:50 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-09-11 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2000-09-06 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-09-06 |
Time |
12:57 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-09-06 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. SUBMIT FIRE SPRINKLER PLANS AND | | | PERMIT APPLICATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-08-18 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-08-18 |
Time |
10:43 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-08-18 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | | | | | | | 1.PROVIDE PRODUCT APPROVAL SHEETS ON | | | HURRICANE SHUTTERS THAT ARE LEGIBLE, | | | PROVIDE DETAIL SHOWING HOW SHUTTERS ARE | | | TO BE SECURED IN STORAGE AND THAT WALLS | | | ARE CAPABLE OF CARRYING THE LOADS | | | IMPOSED, ALSO NEED MORE DETAILS ON | | | INSTULATION (HOW & WHO) FOR APPROVAL | | | BY BUILDING OFFICIAL | | | 2.PROVIDE FLORIDA ENERGY SHEETS SIGNED | | | AND SEALED BY ENG. & OWNER/AGENT | | | 3.SUBMIT FIRE SPRINKLER PLANS AND | | | APPLICATION FOR PERMIT. | | | 4.SUBMIT LETTER FROM SPECIAL INSPECTOR | | | RELEASING SPACE. | | | | | | NOTE: SIGNS UNDER SERPERATE PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-07-28 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-07-28 |
Time |
11:07 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | | | | | | | 1. PROVIDE SIGNED AND SEALED FLORIDA | | | ENERGY SHEETS, 1997 EDITION | | | 2. FIRE SPRINKLER PERMIT REQUIRED PRIOR | | | TO ISSURANCE OF BUILDING PERMIT. | | | 3. EXTERIOR SIGNS REQUIRE SEPRATE PERMIT | | | 4. SUBMIT APPROVAL FROM SPECIAL | | | INSPECTOR. | | | 5. EXTERIOR GLAZING: PROVIDE PRODUCT | | | APPROVAL SHEETS, METRO DADE COUNTY | | | OR SBC 1997 SSTD 12-97 | | | 6. ALL WOOD FRAMING TO BE FIRE RETARDANT | | | LUMBER AS PER SBC 1997 CHAPTERS 6&7 | | | 7. HANDICAP FITTING ROOM: DOOR SHALL NOT | | | SWING INTO TURNING RADIUS, FLORIDA | | | ADA SECTION 4.35.2 | | | 8. PAGE 1: PROJECT DATA CODE REQUIREMENT | | | REVISE NEC 1996 TO NEC 1999. | | | 9. TENTANT SEPERATION TO MEET SBC 1997 | | | TABLE 704.1 OCCUPANCY SEPERATION | | | REQUIREMENTS.( BOTH SIDES MUST BE | | | COMPLETED PRIOR TO C.O.) | | | 10. SHUTTERS ARE INDICATED ON DETAIL14 | | | SHEET 7, PROVIDE PRODUCT APPROVAL | | | INFORMATION SHEETS,INDICATE AREA OF | | | STORAGE, SHOULD SHUTTERS BE STORED ON | | | END SHUTTERS SHALL BE DESIGNED FOR | | | ADDITIONAL LOADING; PROVIDE LETTER | | | FROM TENTANT AS WHO WILL INSTALL AND | | | TIME NEED TO INSTALL FOR APPROVAL OF | | | BUILDING OFFICAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-28 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-28 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-21 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-21 |
Time |
18:37 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *********** UNSAT ************ | | | | | | AS PER CONVERSATION WITH ENGINEER PLANS | | | FOR ELECTRICAL WILL BE CHANGING AGAIN | | | PER LANDLORD.8/21 DV PALMER |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-07-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-25 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-21 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************ UNSAT ******************** | | | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | SHOWING ALL CONTINUOUS LOADS AT 125% | | | (LIGHTING) AND INCULDE SHOW WINDOW AND | | | TRACK LIGHTING LOADS PER 220-12(A,B) | | | | | | 2)NOTE:PLEASE NOTE THAT YOU SHOW GROUND- | | | -ING ELECTRODE REF. ART 250-26, PLEASE | | | SIZE PER ART 250-66 | | | | | | 3)NOTE: PLEASE SUBMIT SOME CLARIFICATION | | | ON HVAC UNIT LOAD? YOU SHOW 2992VA WHERE | | | IS THIS LOAD COMING FROM.? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTION | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2000-09-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-09-12 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-09-12 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2000-08-17 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-17 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO FIRE ALARM EQUIPMENT SHOWN ON | | | PLANS. HOW IS THE BASE BUILDING FIRE | | | ALARM SYSTEM HEARD WITHIN THE SPACE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-07-27 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) SPRINKLER HEADS SHOWN BUT NO PIPING | | | OR HYDRAULIC CALCULATIONS PROVIDED. SOME | | | AREAS APPEAR TO BE NOT PROPERLY | | | PROTECTED BY FIRE SPRINKLERS. | | | 2) TRANSFORMER IN REAR OF STORE SHOULD | | | BE RELOCATED. ALTHOUGH 44" WIDTH IS | | | CODE ALLOWABLE, THE TRANSFORMER BECOMES | | | A PERMANENT OBSTACLE. | | | 3) HOW IS THE BASE BUILDING FIRE ALARM | | | SYSTEM HEARD IN TENANT SPACE WHEN | | | ACTIVATED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-08-21 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-08-21 |
Time |
14:12 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-08-21 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO:::::::: | | | | | | 1. FAN SHUT DOWN BY DUCT SMOKE DETECTOR | | | TO BE TIED TO BUILDING FIRE ALARM OR | | | HORN AND STROBE PER NFPA 90A 4-4.4 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-07-24 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-24 |
Time |
09:40 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-24 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | 1.PROVIDE OUTSIDE AIR SCHEDULE PER | | | ASHRAE 62-89. | | | 2.PROVIDE ENERGY EFFICIENCY RATING OF | | | THE AIR AHU AS PER FLORIDA ENERGY | | | EFFICIENCY CODE. | | | 3.PROVIDE AN AIR BALANCE SCHEDULE AS PER | | | 1997 SMC 501.2.. | | | 4.REQUIRED FIRE AT RATED WALLS WHERE | | | APPLICABLE. | | | 5.REQUIRED AHU , DUCTWORK AND DIFFUSER | | | MOUNTING DETAIL ON PLANS. | | | 6.PROVIDE DUCT MATERIAL SCHEDULE. | | | 7.EXHAUST FANS SCHEDULE REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-08-17 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-17 |
Time |
18:22 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-08-17 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO****************** | | | THE BENCH IN THE HANDICAP FITTING ROOM | | | SHALL BE FIXED ALONG THE WALL WITH THE | | | LONGER DIMENSION PER FACBC SEC.4.35.4. | | | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE | | | P[LUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-07-26 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-07-26 |
Time |
12:59 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|