Plan Review Details - Permit 00070029
Plan Review Stops For Permit 00070029
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-08-09 Cont ID  
Sent By lmartine Date 2000-08-09 Time 10:10 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-07-29 Cont ID  
Sent By lmartine Date 2000-07-29 Time 10:28 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00BUILDING REVIEW COMMENTS
 --------------------------
  
 1]ENERGY CALCULATIONS SHALL BE DONE TO
 COMMERCIAL STANDARDS NOT RESIDENTIAL.
 2]ENTIRE PROJECT SHALL COMPLY WITH THE
 PROVISIONS OF THE 1997 FL.ACC.CODE.
 3]SHEET A-5 HAS NOTED THE INSULATION FOR
 THE NEW ROOF TO BE R-20,PLEASE EXPLAIN
 4]PROVIDE CERTIFICATION FOR MASONRY
 HEADERS ABOVE NEW WINDOWS A&B SIGNED &
 SEALED BY STRUCTURAL ENGINEER.
 5]SUBMIT COUNTY IMPACT FEE RECEIPT FOR
 NEW ADDITION.
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 561-659-8096#8456

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-07-12 Cont ID  
Sent By dpalmer Date 2000-07-12 Time 07:48 Rev Time 0.00
Received By dpalmer Date 2000-07-12 Time 07:48 Sent To  
Notes
2001-01-08 00:00:00**************** PROVISO **************
  
 1)NOTE: PLEASE SUBMIT PLANS SHOWING ALL
 NEW BRANCH CIRCUITS WITH CORRELATING
 #`S TO REVISED PANEL SCHEDULE.
  
 2)NOTE: PLEASE SUBMIT A REVISED LOAD
 CALCULATION. CONTINUOUS LOADS TO BE FIG.
 AT 125% (LIGHTING ETC. ) ART:220
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW BEFORE ROUGH ELECTRICAL
 INSPECTION IS CALLED IN. IF THERE ARE
 ANY QUESTIONS PLEASE CALL 659-8096 EXT.
 8372.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-07-13 Cont ID  
Sent By rturnque Date 2000-07-13 Time 09:59 Rev Time 0.20
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-07 Cont ID  
Sent By cthirben Date 2000-08-07 Time 13:53 Rev Time 1.00
Received By cthirben Date 2000-08-07 Time 13:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2000-07-15 Cont ID  
Sent By jleech Date 2000-07-15 Time 11:56 Rev Time 0.25
Received By jleech Date 2000-07-15 Time 11:57 Sent To  
Notes
2001-01-08 00:00:00NO PLUMBING SHOWN.

Review Stop Z ZONING
Rev No 2 Status P Date 2000-08-10 Cont ID  
Sent By lmartine Date 2000-08-10 Time 09:54 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY ANGELLA 8/10/00
 SEE APPLICATION

Review Stop Z ZONING
Rev No 1 Status F Date 2000-07-07 Cont ID  
Sent By gjoyce Date 2000-07-07 Time 15:49 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEEDS A CLASS B