Plan Review Details - Permit 00061786
Plan Review Stops For Permit 00061786
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-08-02 Cont ID  
Sent By drunnels Date 2000-08-02 Time 18:03 Rev Time 1.00
Received By drunnels Date   Time   Sent To  
Notes
2001-01-08 00:00:00 
 PRODUCT APPROVAL FOR IMPACT RESISTANT
 WINDOW SYSTEM RECEIVED 8-2-00
 WINDOW PROVISO REMOVED FROM THIS PERMIT

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-08-02 Cont ID  
Sent By drunnels Date 2000-08-02 Time 12:30 Rev Time 1.00
Received By drunnels Date   Time   Sent To  
Notes
2001-01-08 00:00:00 
 "POVISO"
  
 PROVIDE PRODUCT APPROVAL FOR WINDOW
 GLAZING PER METRO DADE COUNTY OR SBCCI
 SSTD12-97
 STOREFRONT REQUIRES SEPERATE PERMIT.
  
 NOTE: ALL 1 HOUR FIRE RATED TENANT
 ASSEMBLIES (UL# U465) SHALL BE COMPLETED
 PRIOR TO C.O. BEING ISSUED.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-10-24 Cont ID  
Sent By dpalmer Date 2000-10-24 Time 18:34 Rev Time 0.00
Received By dpalmer Date 2000-10-24 Time 18:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2000-09-28 Cont ID  
Sent By dpalmer Date 2000-09-28 Time 20:15 Rev Time 0.00
Received By dpalmer Date 2000-09-28 Time 20:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-09-22 Cont ID  
Sent By dpalmer Date 2000-09-22 Time 14:16 Rev Time 0.00
Received By dpalmer Date 2000-09-22 Time 14:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-07-31 Cont ID  
Sent By dpalmer Date 2000-07-31 Time 20:16 Rev Time 0.00
Received By dpalmer Date 2000-07-31 Time 20:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-08-02 Cont ID  
Sent By drunnels Date 2000-08-02 Time 15:23 Rev Time 0.00
Received By drunnels Date   Time   Sent To  
Notes
2001-01-08 00:00:001) PROVIDE FIRE ALARM SYSTEM SHOP
 DRAWINGS FOR FIRE ALARM EQUIPMENT
 SHOWN ON POWER PLAN.
 2) EXITING THROUGH STOCKROOM PERMITTED
 IF THE FOLLOWING CONDITIONS EXIST, NOT
 MORE THAN 50 PERCENT OF EXIT ACCESS
 IS PROVIDED THROUGH STOCKROOM, AN AISLE
 OF AT 44" WIDE TO BE PRESENT THROUGH
 STOCKROOM, THE 44" AISLE IS TO BE
 MAINTAINED, AND THE STOCKROOM CANNOT
 BE LOCKED.
 3) AN ADDITIONAL EXIT SIGN MAY BE NEEDED
 TO DIRECT PERSONS TO REAR EXIT DOOR IN
 STOCKROOM.
 FIRE PLAN REVIEW CONDUCTED BY ASST.
 FIRE MARSHAL MIKE CARSILLO

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-01 Cont ID  
Sent By cthirben Date 2000-08-01 Time 12:28 Rev Time 1.00
Received By cthirben Date 2000-08-01 Time 12:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-09-22 Cont ID  
Sent By tlarge Date 2000-09-22 Time 12:42 Rev Time 0.30
Received By tlarge Date 2000-09-22 Time 12:42 Sent To  
Notes
2001-01-08 00:00:00INSTALL POINT OF USE WATER HEATER.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-08-01 Cont ID  
Sent By tlarge Date 2000-08-01 Time 20:11 Rev Time 0.65
Received By tlarge Date 2000-08-01 Time 20:04 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 1)SHT.A1-DRESSING ROOM SHALL COMPLY W/
 FACBC SEC.4.35.4.BENCH SHALL BE LOCATED
 ALONG THE LONGER DIMENSION WALL.
  
 2)WATER CLOSETS NOT PERMITTED WET VENTS
 PER COUNTYWIDE AMENDMENTS TO SPC SEC.
 911.1.1.SUBMIT REVISED SANITARY RISER
 PRIOR TO PLUMBING INSPECTION.
  
 3)POINT OF USE WATER HEATER SHALL BE
 LISTED PER SPC 503.3.
  
 4.)HANDICAP ACESSIBLE TOILET ROOMS SHALL
 BE INDELIBLY POSTED FOR THE INTENDED
 USE,BE ON AN ACCESSIBLE ROUTE,AND
 AVAILABLE TO PATRONS DURING NORMAL
 OPERATING HOURS.ACCESSIBLE ROUTE SHALL
 BE CLEARLY DEFINED ON THE PLANS.
 FACBC SECS.4.1.2(7),4.1.3.(16),4.1.3(11)
 4.2.1.,4.3.1,4.3.2(3),4.3.3.
 SPC SEC.407.2.2.