Plan Review Details - Permit 00061733
Plan Review Stops For Permit 00061733
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-07-05 Cont ID  
Sent By dpalmer Date 2000-07-05 Time 20:33 Rev Time 0.00
Received By dpalmer Date 2000-07-05 Time 20:33 Sent To  
Notes
2001-01-08 00:00:00************* NOTES ON PLANS **********
  
 1)NOTE: MISSING SMOKE DETECTORS IN
 BEDROOM AND CABANA. TO BE WIRED INLINE.
  
 2)NOTE: GFI PROTECTION REQ`D FOR WHIRL-
 -POOL TUB.
  
 3)NOTE: MISSING REQ`D DEDICATED BATH(S)
 CIRCUIT(S) 210-11-3-C
  
 AS-BUILTS TO BE SUBMITTED BEFORE FINAL.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-07-03 Cont ID  
Sent By cthirben Date 2000-07-03 Time 08:51 Rev Time 1.00
Received By cthirben Date 2000-07-03 Time 08:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-02-21 Cont ID  
Sent By jleech Date 2001-02-21 Time 19:46 Rev Time 0.25
Received By jleech Date 2001-02-21 Time 19:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-07-06 Cont ID  
Sent By tlarge Date 2000-07-06 Time 08:51 Rev Time 0.33
Received By tlarge Date 2000-07-06 Time 08:50 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-07-17 Cont ID  
Sent By jgomez Date 2000-07-15 Time 16:38 Rev Time 3.50
Received By jgomez Date 2000-07-17 Time 13:36 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-MISSING SHEET A-1.
 2-ENTRY DOORS TO HAVE 32" CLEAR OPENING
 EACH LEAF. TABLE 1004 SBC 1997.
 3-PROVIDE ATTIC ACCESS AT GUEST AREA.
 SECTION 2309.6 SBC 1997.
 4-SHEET #GN OF ARCHITECTURAL DRAWINGS
 SPECIFIES CERTAIN BRAND NAMES FOR
 ROOF TILE AND DOORS AND WINDOWS.
 ARCHITECT TO APPROVE PRODUCT APPROVALS
 SUBMITTED.
 5-UPDATE/REVISE ALL ORIGINAL DRAWINGS AS
 REQUIRED. SEE COMMENTS ON PLANS,
 INCLUDING COMMENTS BY THE OTHER TRADES
 6-PROVIDE 6 MIL MINIMUM VAPOR BARRIER IN
 CONCRETE SLAB. SECTION 1909.2 SBC 1997
 7-PROVIDE CURRENT PRODUCT APPROVALS FOR:
 -ENTRY DOORS WITH SIDELITES ASSEMBLY.
 -FRENCH DOORS. SINGLE AND DOUBLE.
 -BUTT GLAZING ASSEMBLY.
 -SLIDING GLASS DOORS OF SIZE SHOWN ON
 ARCHITECT'S PLANS.
 -FIXED GLASS WINDOWS OF THE SIZE SHOWN
 AT LIVING AND DINIG AREAS.
 -ARCHITECTURAL WINDOW AT GUEST CLOSET.
 -WINDOW MULLIONS.
 8-PROVIDE DETAILS OF CONCRETE COLUMNS
 SHOWING LOCATION OF STEEL REINFORCING.
 SEE COMMENTS ON FOUNDATION PLAN.
 SECTION 104.2.2 CITY AMENDMENTS.
 9-PROVIDE COMPLETE DETAIL/SPECIFICATIONS
 FOR CEILING CONSTRUCTION AT FRONT AND
 BACK PORCHES. INCLUDING FASTENERS TYPE
 AND SPACING. SECTION 2504 SBC 1997.
 10-SPECIFY CEILING FANS. SEE TABLE 6-6
 FLORIDA ENERGY EFFICIENCY CODE FOR
 BUILDING CONSTRUCTION, 1997 EDITION.
 11-PROVIDE COPIES OF SOIL TESTS DONE AS
 PER SECTION 1804.2.7.3 OF CITY
 AMENDMENTS.
 12-REVISE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM:
 -FORM IS NOT LEGIBLE.
 -MEAN ROOF HEIGHT AND BASIC VELOCITY
 PRESSURE DON'T MATCH. SEE TABLE
 1606.2A SBC 1997.
 -REVISE BUILDING USE FACTOR IS NOT
 CORRECT. SEE TABLE 1606 SBC 1997.
 -EXPLAIN WHY BUILDING IS NOT BEING
 REVIEWED FOR SHEAR WALL REQUIREMENTS.
 13-PROVIDE DRAWINGS FOR BOTH GARAGE
 DOORS TO BE USED. MAKE SURE MODELS
 SELECTED ARE DESIGNED WITH THE MINIMUM
 DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-06-30 Cont ID  
Sent By gjoyce Date 2000-06-30 Time 15:28 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***