| Plan Review Stops For Permit 00061675 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-10-11 |
Time |
07:35 |
Rev Time |
1.50 |
| Received By |
drunnels |
Date |
2000-10-11 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-07-31 |
Time |
15:25 |
Rev Time |
2.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-09-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-09-13 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-09-13 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-09-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-09-26 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-09-26 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-27 |
Time |
06:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-27 |
Time |
06:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE COMPLETE LOAD CALCULATION | | | -S. SHOW ALL CONTINUOUS LOADS AT 125% | | | (LIGHTING) ETC. | | | ALSO SHOW TRACK LIGHTING FIGURED INTO | | | CALCS PER 220-12 | | | | | | 2)NOTE: PLEASE SEE 210-62 FOR SHOW | | | WINDOW RECEPT REQ`MENTS AND TO BE | | | CALCULATED PER 220-12 | | | | | | 3)NOTE: ALL ELECTRICAL BEING SHOWN ON | | | FLOOR PLAN,,, IS ALL THIS NEW? WHAT IS | | | EXISTING? KITCHEN AREA? | | | | | | 4)NOTE: PLEASE NOTE OUTLETS IN KITCHEN | | | AND BATH AREA TO BE GFI/GFI PROTECTED. | | | PER 210-8 | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-10-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-10-13 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLAN APPROVED 8/8/00 BY RHETTLM |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-01-08 |
Time |
10:53 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-01-08 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | THIS MECHANICAL REVISION IS FOR PHASE 1 | | | ONLY. NEW ENGINEER OF RECORD.SEE LETTER | | | INCLUDED WITH PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-09-21 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-09-21 |
Time |
14:43 |
Rev Time |
0.75 |
| Received By |
ndenmark |
Date |
2000-09-21 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-18 |
Time |
18:56 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-18 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED:********************************* | | | 1.PROVIDE DAMPER LOCATION PER 1997 SMC | | | 610.1.2.ALSO DAMPER DETAIL. | | | 2.PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2.. | | | 3.PROVIDE OUTSIDE AIR SCHEDULE PER | | | ASHRAE 62-89. | | | 4.REQUIRE DUCT MATERIAL SCHEDULE. | | | 5.REQUIRE FLEX DUCT CONNECTION DETAIL. | | | 6.LOCAL CODE REQUIRES MIN. 18" OF CLEAR- | | | ANCE BETWEEN ROOF SURFACE AND BOTTOM OF | | | SUPPORT BEAM OF STAND. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-01-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-05 |
Time |
07:33 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-01-05 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED; | | | | | | 1.SHT. P-1 DELETE DRAINAGE LAYOUT. NOT | | | THE SAME AS P-2. | | | | | | 2.SHT. P-1 DELETE SANITARY RISER | | | DIAGRAM. WOMEN ROOMS ARE SHOWN ON P-3 | | | RISER DIAGRAM.P-1 DRAWING IS STILL | | | NEEDED TO SHOW CHANGE IN TRAP PRIMER. | | | | | | 3.ADD NOTE ON P-2 BY DRINKING FOUNTAIN | | | (PROVIDE CUP DISPENSER). | | | | | | 4.SHOW SHOWER DRAIN ON SANITARY LINE | | | DRAWING, P-2. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-10-13 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-13 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-10-13 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-09-16 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-09-16 |
Time |
.8:15 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
2000-09-16 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)RM.123-DOOR CANNOT SWING INTO CLEAR | | | FLOOR SPACE REQD.FOR THE LAVATORY PER | | | FACBC SEC.4.22.2. | | | | | | 2)SINK IN CONCESSION AREA SHALL BE H.C. | | | ACCESSIBLE PER FACBC SEC.4,24.1-4.24.7. | | | | | | 3)FLOOR DRAINS ARE REQD.IN THE TOILET | | | ROOMS PER SPC SEC.409.4.1.1. | | | | | | 4)WALLS AND FLOORS IN TOILET ROOMS SHALL | | | BE NONABSORBENT PER SBC SEC.1204.2. | | | | | | 5)SHOW REQD.WHEELCHAIR TURNING SPACE IN | | | TOILET ROOMS PER FACBC SEC.4.2.3. | | | | | | 6)PLANS SHOW WOMEN'S TOILET ROOM IN | | | ELECTRONICS RETAIL SALES AREA.CLEARLY | | | SHOW HOW MALE PATRONS WILL HAVE FREE | | | ACCESS TO MALE TOILET ROOM. | | | | | | 7)NOTE OCCUPANT LOAD ON PLANS USING SPC | | | TABLE 407 AS A GUIDE.SEE SPC SEC.407.1.3 | | | FOR ALLOWED DEDUCTIBLE AREAS. | | | | | | 8)CALCULATED AIR CHAMBERS SHALL COMPLY | | | W/SPC SEC.607.8.3,607.8.4.IF USED. | | | | | | 9)SHT.P-3-PROVIDE SHIP'S LADDER IN | | | CONJUNCTION W/PLATFORM FOR WATER HEATER | | | PER SPC 501.7. | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-07-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-07-23 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
tlarge |
Date |
2000-09-16 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW | | | (1)SHT.A.1 SPC 94 MIN FACILITIES,TAB 407 | | | MEN1 W/C WOMEN 2 W/C | | | MEN1 LAV WOMEN 2 LAVS | | | DRINKING FOUNTAIN 1 | | | REST RM'S TO COMPLY W/FACBC 4.1.3 (11) | | | D/F TO COMPLY WITH 4.1.3 (10) PROVISIONS | | | SHALL BE MADE FOR PEOPLE WHO HAVE | | | TROUBLE BENDING OR STOOPING. | | | (2)SHT P0.1 ICE MACHINE DETAIL, | | | SEPERATE CUBBER DRAIN & ICE BIB DRAIN. | | | SPC 94 SEC 606.1 CROSSCONNECTION | | | (3) SHT P-3 WATER HEATER TO BE READLY | | | ACCESSIBLE SPC 94 SEC 501.7 RELOCATE TO | | | FLOOR OR PROVIDE A FIXED SHIPS LADDER & | | | WORKING PLATFORM. | | | (4) SHT P3-1SHOW LOCATION OF BACK | | | FLOW PREVENTER AS REQUIRED BY LOCAL | | | ORDINANCE #2853-95 | | | | | | (5) SHT P0.1 GAS WATER HEATER DETAIL | | | DIELECTRIC UNIONS NOT APPROVED IN WATER | | | SUPPLY SYSTEM,USE DIELECTRIC NIPPLES OR | | | COUPLINGS.SPC 94 SEC 611.2 MATERIALS A/G | | | (6) SHT P0.1 IF DETAILS SHOWN,DO NOT | | | APPLY,DELETE OR VOID THEM. | | | END OF COMMENTS |
|
|