Plan Review Details - Permit 00061631
| Plan Review Stops For Permit 00061631 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-26 |
Time |
19:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-26 |
Time |
19:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** PROVISO ***************** | | | | | | 1)NOTE: PLEASE SEE ORIG NOTES AND STILL | | | NEED TO ADDRESS 3,4,5,6. | | | | | | 2)NOTE: NEED TO REVISE RISER DIAGRAM | | | TO MEET THE REQ`MENTS FOR DROPS TO RES- | | | -IDENCE AND GROUPED OF DISCONNECTS. | | | ALSO REVISE FOR ONLY ONE METER. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW BEFORE ROUGH ELECTRICAL INSPECT- | | | -ION IS CALLED IN. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-07-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-10 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-10 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE CLARIFY THE FOLLOWING. | | | THERE ARE NO DOORS SHOWN FOR BEDROOM OR | | | SEPARATING LIVING ROOM? NEED TO MEET THE | | | REQ`MENTS FOR SMOKE DETECTORS SO PLEASE | | | MAKE DOOR LOCATIONS(IF ANY ) AVAILABLE. | | | | | | 2)NOTE: NO SECOND MEANS OF COOKING | | | PERMITTED. THIS MEANS NO ELECTRICAL | | | IS TO BE INSTALLED FOR COOKING EQUIPMENT | | | | | | 3)NOTE: CLOSET SHOWN IN LIVING ROOM | | | CONTAINS AHU AND DISCONNECT. THIS NEEDS | | | TO BESEPARATED SPACE FROM CLOTHING. | | | WALL/ SEPARATION TO BE INSTALLED W/ | | | CLEARENCES DESIGNED PER 110-26 OF THE | | | NEC. | | | | | | 4)NOTE: PLEASE NOTE THE REQ`D REC FOR | | | A/C CU`S. | | | | | | 5)NOTE: PLEASE NOTE THAT THERE IS TO BE | | | ONLY ONE SERVICE DROP TO PROPERTY. THIS | | | IS ZONED SF-7 WHICH IS PERMITTED FOR | | | SINGLE FAMILY. ONLY ONE METER WILL BE | | | ALLOWED. | | | | | | 6)NOTE; PLEASE SUBMIT LOAD CALCULATIONS | | | FOR SERVICE.ALSO SUBMIT AIC RATING OF | | | EQUIPMENT MAINS PER 110-9 | | | | | | | | | PLEASE SUBMIT THE ABPVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2000-07-25 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-25 |
Time |
08:37 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-25 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | UNAST: | | | MECHANICAL PLANS REQUIRED FOR REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-07-12 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-12 |
Time |
07:55 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-12 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED********************************** | | | PROVIDE MECHANICAL PLANS FOR REVIEW. | | | NO PLANS SUBMITTED FOR REVIEW. 07.12.00 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-07-11 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-11 |
Time |
08:59 |
Rev Time |
0.30 |
| Received By |
pschmitz |
Date |
2000-07-11 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-08-14 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-08-14 |
Time |
10:09 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2000-08-14 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-07-31 |
Time |
10:17 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-07-31 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ***************UNSAT******************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE ENERGY CALCULATIONS AND | | | MANUEL J FORM. | | | | | | 2)PROVIDE DESIGN COMPLIANCE FORM FOR | | | BUILDING CONSTRUCTION. | | | | | | 3)PROVIDE DATE WITH ARCHITECTS SEAL AND | | | SIGNATURE. | | | | | | 4)PROVIDE ROOF SHEATHING NAILING ZONES | | | THAT COMPLY WITH SBC FIG 2306.1 CITY | | | AMENDMENTS. | | | | | | 5)PROVIDE SOIL REPORT. | | | | | | 6)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | A)ALL EXTERIOR DOORS | | | B)WINDOWS, FIXED, RADIUS, MULLIONS | | | AND GLASS BLOCK. | | | C)ROOF COVERING | | | D)STORM PANELS WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | | ANCHORS TO BE USED. | | | | | | 7)PROVIDE STRUCUAL NOTES THAT REFERENCE | | | 1997 SBC ONLY. | | | | | | 8)BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-06-30 |
Time |
14:57 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | FRONT S/B NEEDS TO BR 25' | | | 1 KITCHEN ALLOWED SF 7 ZONING |
|
|
|