| Plan Review Stops For Permit 00061244 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2000-08-22 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-08-22 |
Time |
10:28 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-08-22 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-08-14 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-08-14 |
Time |
07:13 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-08-14 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. SUBMIT FIRE SPRINKLER PERMIT PLANS & | | | APPLICATION. FIRE SPRINKLER PERMIT TO BE | | | ISSUED PRIOR TO BUILDING ISSURANCE OF | | | BUILDING PERMIT. | | | 2.SUBMIT PRODUCT APPROVAL FOR WINDOW AND | | | DOORS FOR STOREFRONT. METRO DADE COUNTY | | | OR SBCCI. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-07-31 |
Time |
15:55 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | | | | 1.LETTER FROM SPECIAL INSPECTOR | | | RELEASING SPACE | | | 2. SUBMIT PRODUCT APPROVALS PER 1997 SBC | | | SSTD12-97 OR METRO DADE ON DOORS & | | | WINDOWS & STOREFRONTS. | | | 3. SUBMIT ENERGY CALCS. WITH SIGNATURE | | | OF OWNER/AGENT WHERE NOTED. | | | 4. FIRE SPRINKLER PERMIT TO BE ISSURED | | | PRIOR TO ISSURANCE OF BUILDING PERMIT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-07-03 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2000-07-03 |
Time |
09:43 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | 1.FIRE SPRINKLER PERMIT TO BE ISSUED | | | PRIOR TO ISSUANCE OF BUILDING PERMIT. | | | 2.LETTER FROM SPEC. INSPECTOR RELEASING | | | SPACE. | | | 3. NEED ROOMS LABELED ON PLANS | | | 4. PROVIDE COMPLETE SEATING DETAILS | | | 5. DIMENSIONS ON PLANS INCOMPLETE | | | 6. CLARIFY REFERENCES TO 1-A.1 & A-A.5 | | | ON SHEET A-1. | | | 7. SHOW WALL DETAILS FOR 2 HR DEMISING | | | WALL SHOWN ON PLANS.LISTING FROMEX UL | | | 8. SUBMIT PRODUCT APPROVALS PER 1997 SBC | | | SSTD12-97 OR METRO DADE ON DOORS & | | | WINDOWS & STOREFRONTS. | | | | | | 9.SUBMIT ENERGY CALCS. WITH SIGNATURES | | | WHERE NOTED BY OWNER & ARCH. | | | 11. BUILDING CODE REFERENCED ON COVER | | | PAGE REFERENCES 1994/ SHOULD BE 1997. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-07-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-28 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-28 |
Time |
07:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-27 |
Time |
20:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-27 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** PROVISO ************* | | | | | | 1)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. PLEASE SHOW LOAD CALCULATIONS. | | | | | | | | | 2)NOTE: PLEASE SUBMIT ALL AIC RATINGS | | | OF ALL EQUIPMENT. MAINS/PANELS ARE TO BE | | | RATED FOR ALL AVAILABLE FAULT CURRENTS. | | | 110-9/215-5 | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2000-08-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-08-18 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2000-07-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-07-28 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO FIRE SPRINKLER SYSTEM PLANS OR | | | HYDRAULIC CALCULATIONS PROVIDED WITH | | | DRAWINGS. | | | 2) IN ASSEMBLY OCCUPANCIES, THE MAIN | | | EXIT DOOR(S) CAN BE EQUIPPED WITH | | | LOCKING DEVICES IN ACCORDANCE WITH | | | SECTION 5-2.1.5.1., IF THE OCCUPANT | | | LOAD IS LESS THAN 500 PERSONS. OTHER | | | EXIT DOORS MUS COMPLY WITH THE PANIC | | | HARDWARE REQUIREMENT. | | | 3) PROVIDE PLANS AND PERMIT FOR THE | | | INSTALLATION OF FIRE ALARM EQUIPMENT | | | IN THE TENANT SPACE. | | | 4) PROVIDE COMPLETE SHOP DRAWINGS FOR | | | THE INSTALLATION OF THE HOOD,DUCT AND | | | EXTINGUISHING SYSTEMS. | | | 5) GAS INSTALLATION TO COMPLY WITH | | | NFPA 54. | | | 6) OCCUPANT LOAD TO BE DETERMINED BY | | | THIS OFFICE. | | | 7) PROVISIONS ARE TO BE MADE FOR AT | | | LEAST TWO HANDICAPPED PERSONS. | | | 8) PROVIDE FLAMESPREAD INFORMATION TO | | | THE FIRE MARSHALS OFFICE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-07-03 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-07-03 |
Time |
09:40 |
Rev Time |
1.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED SEE ATTACHMENT, M. CARSILLO 6/29 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-26 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-26 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-07-26 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTES: | | | ADDITIONAL PERMIT REQUIRED FOR HOODS, | | | FIRE SUPPRESSION, FUEL, WALK-IN COOLER/ | | | FREEZER | | | PROVISO: | | | FIRE DAMPERS REQUIRED AT RATED WALLS | | | WHERE THE DUCT PENETRATES AS PER 1997 | | | SMC 610.1.2.... |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-24 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-06-23 |
Time |
16:25 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-06-24 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED:****************************** | | | THE FOLLOWING REQUIREMENTS ARE TO BE | | | PROVIDED: | | | 1. PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2. | | | 2. DUCT MATERIAL SCHEDULE PER FLORIDA | | | ENERGY CODE. | | | 3. FLEX DUCT CONNECTION DETAIL. | | | 4. GRILLE, DIFFUSERS AND REGISTERS | | | SCHEDULE. | | | | | | PROVISO: | | | SEPERATE PERMIT REQUIRED FOR HOOD, | | | GAS, FIRE-SUPPRESSION SYSTEM,WALK-IN | | | COOLERS/FREEZERS. | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | WITH NOTIFICATION BY FIRE ALARM SYS- | | | TEM OR TIED-IN TO HORN AND STROBE AS | | | PER NFPA 90A 4.4.4.2 AND 4.4.4.3.. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2000-12-31 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-12-31 |
Time |
09:55 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: SHT.A-4.1 | | | CORRIDOR GAS PIPING ON A SEPERATE DRWG. | | | ON FILE.PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-08-10 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-08-10 |
Time |
22:56 |
Rev Time |
0.50 |
| Received By |
tlarge |
Date |
2000-08-10 |
Time |
22:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-07-30 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-30 |
Time |
06:27 |
Rev Time |
2.75 |
| Received By |
tlarge |
Date |
2000-07-29 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | `1)WIDTH OF HANDICAP TOILET STALL DOOR | | | OPENING SHALL COMPLY W/FACBC SEC.4.17.5 | | | AND FIGURE 30.SHT.A1. | | | | | | 2)MIN.WIDTH OF HANDICAP STALL SHALL BE | | | 83" PER FACBC SEC.4.17.3,SPC 403.1 | | | | | | 3)THE WATER HEATER LISTING IS OVER | | | 200,000 BTU'S AND THEREFORE CLASSIFIED | | | AS A BOILER AND SHALL COMPLY W/THE | | | FOLLOWING CODE SECS.: | | | A)SGC SECS.507.7,507.8 | | | B)SMC SEC.1003.1-1003.4. | | | C)SMC SEC.1004.1,1004.2. | | | D)TABLE 1003,FOOTNOTE #8. | | | E)SBC 704.1.3.3. | | | SUBMIT MANUF.SHEETS FOR BOILER. | | | | | | 4)SHT.A4.1-DRY VENTS NOT PERMITTED PER | | | SPC SEC.906.2.1.(SEE FLOOR SINK & W.C.) | | | | | | 5)WATER CLOSETS AND FIXTURE BRANCHES NOT | | | PERMITTED ON WET VENTS PER COUNTYWIDE | | | AMENDMENTS TO SPC SEC.911.1.1. | | | | | | 6)CIRCUIT AND LOOP SYSTEM SAHLL COMPLY | | | W/SPC SEC.914.2. | | | | | | 7)SIZE OF HORIZONTAL DRAIN FOR W.C.'S IN | | | WOMEN'S R.R.SHALL COMPLY W/SPC TABLE | | | 714.2,FOOTNOTE #2. | | | | | | 8)FLOOR SINK AND HAND SINK SHALL | | | DISCHARGE TO G.W.PER 1004.1,1004.4. | | | | | | 9)SHT.A4.1-SIZING/DESIGN OF GAS SYSTEM | | | SHALL COMPLY W/SGC.SYSTEM IS UNDERSIZED | | | AS DESIGNED.SEE ATTACHED LIST FOR GAS | | | DRAWING REQS. | | | | | | CALL 561-659-8096 EXT.8377 IF YOU HAVE | | | ANY QUESTIONS. | | | TIMOTHY LARGE,PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-27 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-27 |
Time |
21:14 |
Rev Time |
1.50 |
| Received By |
tlarge |
Date |
2000-06-27 |
Time |
20:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SIZE OF HANDICAP STALL SHALL COMPLY W/ | | | FACBC SEC.4.17.3 | | | | | | DISHWASHER SHALL DISCHARGE TO SANITARY | | | PER CITY OF WPB ORDINANCE. | | | | | | DRY VENTS NOT PERMITTED PER SPC SEC. | | | 906.2.1.(SEE RESTROOMS AND GREASY WASTE) | | | | | | WATER CLOSETS AND FIXTURE BRANCHES NOT | | | PERMITTED ON WET VENTS PER COUNTYWIDE | | | AMENDMENTS SEC.911.1.1. | | | | | | CIRCUIT AND LOOP SYSTEM SHALL COMPLY W/ | | | SPC SEC.914.2. | | | | | | SIZE OF HORIZ.DRAIN FOR WATER CLOSETS | | | AND URINALS SHALL COMPLY W/SPC TABLE | | | 714.2,FOOTNOTE #2. | | | | | | FLOOR SINK AND HAND SINK SHALL DRAIN TO | | | GREASY WASTE PER SPC SEC.1004.4. | | | | | | TWO WAY CLEANOUT REQD.ON BUILDING DRAIN | | | (GREASY WASTE)PER SPC SEC.710.4. | | | | | | FLOOR SINK SHALL BE USED IN LIEU OF HUB | | | DRAIN.SPC 807.1.2.,807.1.3. | | | | | | A UNION IS REQD.DOWNSTREAM OF GAS | | | CONTROLS PER NFPA 54 SEC.5.5.4. | | | | | | SUBMIT COPY OF/OR MAKE REFERENCE TO | | | APPLICABLE GAS SIZING TABLE USED FOR | | | SYSTEM DESIGN.SYSTEM DOES NOT COMPLY W/ | | | SGC FOR PROPER SIZING. | | | | | | HEATERS OVER 200,000 BTU'S SHALL COMPLY | | | W/SPC SEC.507.7. | | | | | | SIZE THE C.W.DROP TO THE MENS/LADIES | | | RESTROOMS.COMPLY W/COUNTYWIDE AMENDMENTS | | | SEC.607.7. | | | | | | WATER SUPPLY TO RESTROOMS AND KIT.AREA | | | SHALL COMPLY W/SPC SEC.610.4.1.,610.4.2. | | | | | | WATER DIAGRAM SHOWS OVER 2 FIXTURES ON | | | 1/2" C.W.LINE.COMPLY W/SPC SEC.607.7. | | | | | | GREASY WASTE SYSTEM SHOWS 6"LINE | | | DRAINING INTO 4"LINE.COMPLY W/SPC SEC. | | | 307.5. | | | | | | IF YOU HAVE ANY QUESTIONS I CAN BE | | | REACHED AT 561-659-8096,EXT.8377. | | | TIMOTHY LARGE,PLUMBING PLANS EXAMINER. |
|
|