Plan Review Details - Permit 00060865
Plan Review Stops For Permit 00060865
Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-01-30 Cont ID  
Sent By dpalmer Date 2001-01-30 Time 09:26 Rev Time 0.00
Received By dpalmer Date 2001-01-30 Time 09:26 Sent To  
Notes
2001-01-30 00:00:00**************** UNSAT *****************
  
 1)NOTE: PLEASE HAVE ALL CHANGES ON PLANS
 DONE BY THE ARCH/ENGINEER/DESIGNER OF
 RECORD.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS PLEAS
 E CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-08-25 Cont ID  
Sent By dpalmer Date 2000-08-25 Time 10:30 Rev Time 0.00
Received By dpalmer Date 2000-08-25 Time 10:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-08-23 Cont ID  
Sent By dpalmer Date 2000-08-23 Time 14:33 Rev Time 0.00
Received By dpalmer Date 2000-08-23 Time 14:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-06-21 Cont ID  
Sent By dpalmer Date 2000-06-21 Time 18:38 Rev Time 0.00
Received By dpalmer Date 2000-06-21 Time 18:38 Sent To  
Notes
2001-01-08 00:00:00****************** UNSAT ***************
  
 1)NOTE: PLEASE SUBMIT THE AIC RATING OF
 NEW MAIN AND PANEL. MAINS/PANELS ARE TO
 BE RATED FOR THE AVAILABLE FAULT CURRENT
 AS PER 110-9 AND 215-5
  
 2)NOTE: YOU SHOW A NEW 100 AMP MAIN AND
 PANEL? #6 FEEDING AND LOAD EXCEEDING
 THE RATINGOF #6? PLEASE CORRECT.
  
 3)NOTE: PLEASE DOUBLE CHECK AS TO IF
 THERE ARE ANY OTHER A/C LOADS IN HOUSE
 AND IF SO SUBMIT ON LOAD CALCULATION.
  
 4)NOTE: SMOKE DETECTORS ARE REQ`D INSIDE
 AND OUTSIDE THE NEW SLEEPING ROOM AS PER
 NFPA-72 2-2.1.1.1.
  
 5)NOTE: PLEASE ALSO NOTE THAT THE GROUND
 -ING ELECTRODE OF SERVICE NEEDS TO GO TO
 BLDG. STEEL OF NEW ADDITION.
  
 6)NOTE: PLEASE SEE 210-70 FOR MEANS OF
 EGRESS LIGHTING REQ`D LEAVING SUN ROOM.
 CAN BE 4-WAY OR ???
  
 7)NOTE:ALSO PLEASE NOTE THAT THE SWITCH
 FOR MEANS OF EGRESS LIGHTING LEAVING
 MASTER BEDRROM NEEDS TO BE INSIDE THE
 BEDRROM. 210-70
  
 8)NOTE:PLEASE LIST ON THE PANEL SCHEDULE
 THE REQ`D BATH(S) CIRCUIT(S) AS PER
 210-11-C-3
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-06-26 Cont ID  
Sent By cthirben Date 2000-06-26 Time 12:12 Rev Time 1.00
Received By cthirben Date 2000-06-26 Time 12:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-06-23 Cont ID  
Sent By tlarge Date 2000-06-23 Time 09:44 Rev Time 0.30
Received By tlarge Date 2000-06-23 Time 09:44 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-08-28 Cont ID  
Sent By rmcdouga Date 2000-08-28 Time 16:07 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO
 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 WINDOWS AND DOORS THAT WILL BE INSTALLED
  
 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS, KEY PLAN AND
 INSTALLATION SCHEDULE UNDER A SEPARATE
 PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-07-25 Cont ID  
Sent By rmcdouga Date 2000-07-25 Time 11:53 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 WINDOWS AND DOORS. MUST BE SPECIFIC FOR
 EACH TYPE DOOR OR WINDOW USED.
 NOTE:SITE SPECIFIC ENGINEERING IS ACCEPT
 -ABLE FOR RELOCATED WINDOWS AND DOORS.
 SUBMIT CITY OF WPB PRODUCT APPROVAL FORM
 SIGNED AND SEALED BY ENGINEER CERTIFYING
 PRODUCT AND REVIEWED & APPROVED BY THE
 DESIGN PROFESSIONAL OF RECORD.
 (SEE ATTACHED)
  
 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR REQUIRED
 MISSLE IMPACT PROTECTION (STORM PANELS),
 KEY PLAN AND INSTALLATION SCHEDULE WITH
 SPECIFIC ANCHORS TO BE USED.
  
 3)SHEET S-1 OF PLANS SPECIFY SIMPSON
 MPAHD HOLDOWNS @ EACH STUD. I DID NOT
 SEE THIS PARTICULAR FASTENING DEVICE
 LISTED IN THE SIMPSON PRODUCT CATALOG.
 ARE YOU REFERRING TO HPAHD.
 PLEASE CLARIFY.
  
 4)PROVIDE 2 COMPLETED DESIGN COMPLIANCE
 FORMS,SIGNED AND SEALED BY ENGINEER OR
 ARCHITECT.(SEE ATTACHED)
  
 5)PROVIDE 2 COPIES OF SOIL COMPACTION
 TEST PRIOR TO 1ST INSPECTION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-06-21 Cont ID  
Sent By gjoyce Date 2000-06-21 Time 09:26 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***