Plan Review Details - Permit 00060865
| Plan Review Stops For Permit 00060865 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-30 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-30 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2001-01-30 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE HAVE ALL CHANGES ON PLANS | | | DONE BY THE ARCH/ENGINEER/DESIGNER OF | | | RECORD. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS PLEAS | | | E CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-25 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-25 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-23 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-08-23 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-21 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-21 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT THE AIC RATING OF | | | NEW MAIN AND PANEL. MAINS/PANELS ARE TO | | | BE RATED FOR THE AVAILABLE FAULT CURRENT | | | AS PER 110-9 AND 215-5 | | | | | | 2)NOTE: YOU SHOW A NEW 100 AMP MAIN AND | | | PANEL? #6 FEEDING AND LOAD EXCEEDING | | | THE RATINGOF #6? PLEASE CORRECT. | | | | | | 3)NOTE: PLEASE DOUBLE CHECK AS TO IF | | | THERE ARE ANY OTHER A/C LOADS IN HOUSE | | | AND IF SO SUBMIT ON LOAD CALCULATION. | | | | | | 4)NOTE: SMOKE DETECTORS ARE REQ`D INSIDE | | | AND OUTSIDE THE NEW SLEEPING ROOM AS PER | | | NFPA-72 2-2.1.1.1. | | | | | | 5)NOTE: PLEASE ALSO NOTE THAT THE GROUND | | | -ING ELECTRODE OF SERVICE NEEDS TO GO TO | | | BLDG. STEEL OF NEW ADDITION. | | | | | | 6)NOTE: PLEASE SEE 210-70 FOR MEANS OF | | | EGRESS LIGHTING REQ`D LEAVING SUN ROOM. | | | CAN BE 4-WAY OR ??? | | | | | | 7)NOTE:ALSO PLEASE NOTE THAT THE SWITCH | | | FOR MEANS OF EGRESS LIGHTING LEAVING | | | MASTER BEDRROM NEEDS TO BE INSIDE THE | | | BEDRROM. 210-70 | | | | | | 8)NOTE:PLEASE LIST ON THE PANEL SCHEDULE | | | THE REQ`D BATH(S) CIRCUIT(S) AS PER | | | 210-11-C-3 | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-06-26 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-06-26 |
Time |
12:12 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-06-26 |
Time |
12:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-06-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-23 |
Time |
09:44 |
Rev Time |
0.30 |
| Received By |
tlarge |
Date |
2000-06-23 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-08-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-08-28 |
Time |
16:07 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO | | | 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR EXTERIOR | | | WINDOWS AND DOORS THAT WILL BE INSTALLED | | | | | | 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS, KEY PLAN AND | | | INSTALLATION SCHEDULE UNDER A SEPARATE | | | PERMIT. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-07-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-07-25 |
Time |
11:53 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | | | | 1)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR EXTERIOR | | | WINDOWS AND DOORS. MUST BE SPECIFIC FOR | | | EACH TYPE DOOR OR WINDOW USED. | | | NOTE:SITE SPECIFIC ENGINEERING IS ACCEPT | | | -ABLE FOR RELOCATED WINDOWS AND DOORS. | | | SUBMIT CITY OF WPB PRODUCT APPROVAL FORM | | | SIGNED AND SEALED BY ENGINEER CERTIFYING | | | PRODUCT AND REVIEWED & APPROVED BY THE | | | DESIGN PROFESSIONAL OF RECORD. | | | (SEE ATTACHED) | | | | | | 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | | OR SBCCI PRODUCT APPROVALS FOR REQUIRED | | | MISSLE IMPACT PROTECTION (STORM PANELS), | | | KEY PLAN AND INSTALLATION SCHEDULE WITH | | | SPECIFIC ANCHORS TO BE USED. | | | | | | 3)SHEET S-1 OF PLANS SPECIFY SIMPSON | | | MPAHD HOLDOWNS @ EACH STUD. I DID NOT | | | SEE THIS PARTICULAR FASTENING DEVICE | | | LISTED IN THE SIMPSON PRODUCT CATALOG. | | | ARE YOU REFERRING TO HPAHD. | | | PLEASE CLARIFY. | | | | | | 4)PROVIDE 2 COMPLETED DESIGN COMPLIANCE | | | FORMS,SIGNED AND SEALED BY ENGINEER OR | | | ARCHITECT.(SEE ATTACHED) | | | | | | 5)PROVIDE 2 COPIES OF SOIL COMPACTION | | | TEST PRIOR TO 1ST INSPECTION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-06-21 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-06-21 |
Time |
09:26 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|