| Plan Review Stops For Permit 00060828 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2000-08-08 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-08-08 |
Time |
08:45 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-08-08 |
Time |
08:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2000-07-14 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-07-14 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
drunnels |
Date |
2000-07-14 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. LETTER FROM SPECIAL INSPECTOR | | | RELEASING THE SPACE. CALLED J. COLLIER | | | 7/14/00. | | | 2. FIRE SPRINKLER LAY OUT AND PERMIT | | | MUST BE APPLIED FOR. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-06-28 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-06-28 |
Time |
15:52 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.FLORIDA ENERGY SHEETS NOT SIGNED BY | | | OWNER SEE #3 PRIOR REVIEW. | | | 2. FIRE SPRINLER PERMIT REQUIRED PRIOR | | | ISSUANCE OF BUILDING PERMIT. SEE #4 | | | PRIOR REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-15 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-06-15 |
Time |
10:05 |
Rev Time |
2.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. SHEET AA GLAZING IMPACT CODE | | | REFERENCE REVISE TO SSTD 12-97. | | | 2. PROVIDE PRODUCT APPROVAL INFORMATION | | | FOR ALL EXTERIOR GLAZING. | | | 3. PROVIDE SIGNED AND SEALED FLORIDA | | | ENERGY SHEETS 1997 EDITION. | | | 4. FIRE SPRINKLER PERMIT REQUIRED PRIOR | | | TO ISSUANCE OF THE BUILDING PERMIT. | | | 4. EXTERIOR SIGNS REQUIRE SEPATATE | | | PERMITS. | | | 5. SHEET A-1 PARTATION TYPE #1 REVISE TO | | | COMPLETE BOTH SIDES OF FIRE SEPARATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-29 |
Time |
19:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-29 |
Time |
19:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-19 |
Time |
19:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-19 |
Time |
19:16 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE PROVIDE AIC RATING OF | | | 200AMP CB DISCONNECT INLINE FROM THE | | | TRANSFORMER TO PANEL-A. 215-5 | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | `EVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 561-659-8096 EXT 8372 | | | DEWEY PALMER ELECTRICAL PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-07-05 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-06-19 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO M. CARSILLO SEE NOTES ATTACHED | | | TO PLANS. WRS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-06-30 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-06-30 |
Time |
10:30 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-06-30 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTES : MET ALL REQUIREMENTS REQUESTED | | | BY NCD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-06-19 |
Time |
07:31 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-06-19 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************DENIED******************** | | | | | | 1. 1997 SMC 610 REQUIRES FIRE DAMPERS AT | | | ALL PENETRATIONS OF RATED WALLS | | | 2. SMC 610.6 REQUIRES THAT THE SPECIFIC | | | LOCATION AND INSTALLATION DETAILS OF EA. | | | FIRE DAMPER SHALL BE SHOWN AND PROPERLY | | | IDENTIFIED ON THE BUILDING PLANS BY THE | | | DESIGNER | | | 3. PROVIDE ENERGY EFFIECIENCY RATING OF | | | AHU. | | | 4. OUTSIDE AIR PER ASHRAE 62-89 REQUIRED | | | 5. PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-07-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-07-15 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2000-07-15 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-06-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-29 |
Time |
16:26 |
Rev Time |
0.65 |
| Received By |
pschmitz |
Date |
2000-06-29 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | OCCUPANT LOAD SHALL BE DETERMINED PER | | | TABLE 407 OF SPC. | | | | | | SHT.P-1 NOTES "SEE ARCH.DRWGS.FOR ACCESS | | | DETAILS FOR EWH".NO DETAILS ARE SHOWN. | | | SUBMIT FOR REVIEW.COMPLY W/SPC SEC. | | | 501.7. | | | | | | DRESSING ROOM SHALL COMPLY W/FACBC SEC. | | | 4.35.1-4.35.5. | | | | | | DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | | SEC.4.1.3(10)(A).PROVISIONS SHALL BE | | | MADE FOR PEOPLE WHO HAVE TROUBLE BENDING | | | OR STOOPING. | | | | | | NOTE:OCCUPANT LOAD AS LISTED REQUIRES | | | ADDITIONAL PLUMBING FIXTURES PER TABLE | | | 407 OF SPC. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-18 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-18 |
Time |
05:41 |
Rev Time |
1.75 |
| Received By |
pschmitz |
Date |
2000-06-18 |
Time |
05:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SHT.AA-INCORPORATE THE STANDARD PLUMBING | | | CODE,1994 EDITION INTO CODE COMPLIANCE | | | DATA LEGEND.COUNTYWIDE AMENDMENTS TO SPC | | | SEC.101.2,101.4.6.,F.S.553.06. | | | B)THE ADOPTED STANDARD GAS CODE IS THE | | | 1997 EDITION. | | | C)THE ADOPTED ACCESSIBILITY CODE IS THE | | | FLA.ACCESSIBILITY CODE FOR BUILDING | | | CONSTRUCTION-OCTOBER 1997 EDITION. | | | | | | SUBMIT SQUARE FOOTAGE OF HABITABLE FLOOR | | | SPACE FOR DETERMINATION OF MINIMUM | | | SANITARY FACILITIES.SEE SPC SEC.407.1.3. | | | FOR ALLOWED DEDUCTIBLE AREAS. | | | | | | A MINIMUM OF ONE DRINKING FOUNTAIN IS | | | REQUIRED PER SPC TABLE 407.FOUNTAIN | | | SHALL COMPLY W/FACBC SEC.4.1.3.(10)(A). | | | PROVISIONS SHALL BE MADE FOR PEOPLE WHO | | | HAVE TROUBLE BENDING OR STOOPING. | | | | | | DRESSING ROOM SHALL COMPLY W/FACBC SEC. | | | 4.35.4.(BENCH SHALL BE FIXED ALONG LONG | | | WALL). | | | | | | SHT.A-8A-GRAB BARS ALONGSIDE WATER | | | CLOSET SHALL BE A MIN.OF 42".DETAILS C & | | | G NOTE 36". | | | | | | FLUSH CONTROLS FOR WATER CLOSETS SHALL | | | BE LOCATED ON THE WIDE SIDE OF THE | | | WATER CLOSET PER FACBC SEC.4.16.5. | | | | | | SHT.A-8A SHOWS HEIGHT OF ACCESSIBLE | | | WATER CLOSETS AS 15".COMPLY W/FACBC SEC. | | | 4.16.3. | | | | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | | PER SPC SEC.501.7.SUPPLY FIXED LADDER | | | OR RELOCATE EWH TO FLOOR. | | | | | | WATER CLOSETS NOT PERMITTED ON WET VENTS | | | PER COUNTYWIDE AMENDMENTS SEC.911.1.1. | | | OR COMPLY W/SPC SEC.914.1 FOR CIRCUIT | | | AND LOOP VEN SYSTEM IF THAT IS THE | | | INTENT. |
|
|