Plan Review Details - Permit 00060672
Plan Review Stops For Permit 00060672
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2000-11-22 Cont ID  
Sent By drunnels Date 2000-11-22 Time 10:00 Rev Time 2.00
Received By drunnels Date 2000-11-22 Time 10:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-08-14 Cont ID  
Sent By bstaples Date 2000-08-14 Time 14:56 Rev Time 2.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO
  
 1. PROVIDE PRODUCT APPROVAL INFORMATION
 FOR WINDOWS AND DOORS TO MEET 1997 SBC
 FOR WIND LOADS. PROVIDE PRODUCT APPROVAL
 FOR SHUTTERS TO MEET IMPACT RESISTANT
 CODES USE SSTD12-97 OR METRO DADE COUNTY
  
 2. PROVIDE PRODUCT APPROVAL FOR WINDOW
 NEXT TO EXIT STAIR 1 1/2 HOUR RATING
 REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-07-11 Cont ID  
Sent By bstaples Date 2000-07-11 Time 14:14 Rev Time 2.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:001. ITEM #1 PRIOR REVIEW NOT SUBMITTED
 LETTER FROM SPECIAL INSPECTOR.
 2. ITEM #3 PRIOR REVIEW NOT SUBMITTED
 PRODUCT APPROVAL INFORMATION FOR
 EXTERIOR GLAZING.
 3. ITEM #5 PRIOR REVIEW OT ADDRESSED
 FIRE RATING OF OPENINGS REQUIRED
 SHEET A5.5 SECTION1 NORTH ELEVATION
 SHEET A5.6 SECTION 1 EAST ELEVATION
 ALL OPEANINGE WITHIN 10 FEET SHALL BE
 PROTECTED. SEE 1997 SBC CH. 6, 7 AND 10.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-06-22 Cont ID  
Sent By bstaples Date 2000-06-22 Time 13:01 Rev Time 2.00
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:001. LETTER FROM SPECIAL INSPECTOR
 RELEASINF SPACE.
 2. FIRE SPRINKLER PERMIT TO BE ISSUED
 PRIOR TO ISSUANCE OF BUILDING PERMIT.
 3. EXTERIOR GLAZING PROVIDE PRODUCT
 APPROVAL INFORMATION, METRO DADE COUNTY
 OR STANDARD BUILDING CODE 1997, SSTD1297
 4. SHEET A-5.1, SECTION 5 ALL PLYWOOD
 AND WOOD FRAMING TO BE PRESSURE TREATED
 FIR RETARDANT LUMBER. SEE 1997 SBC
 CHAPTERS 6 AND 7, FOR TYPE 2
 CONSTRUCTION.
 5. SHEET A5.5 OPEANINGSUNDER STAIRS
 SHALL BE FIRE RATED IF WITHIN 10 FEET
 SEE 1997 SBC CHAPTERS 6, 7 AND 10.
  
  
 7. SIGNS REQUIRE SEPERATE PERMITS.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2001-03-08 Cont ID  
Sent By dpalmer Date 2001-03-08 Time 09:20 Rev Time 0.00
Received By dpalmer Date 2001-03-08 Time 09:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2000-11-14 Cont ID  
Sent By dpalmer Date 2000-11-14 Time 21:15 Rev Time 0.00
Received By dpalmer Date 2000-11-14 Time 21:15 Sent To  
Notes
2001-01-08 00:00:00***** NOTE****
 COVER SHEET STILL SHOWS 96 NEC??
 HANDWROTE "99"

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-08-09 Cont ID  
Sent By dpalmer Date 2000-08-09 Time 09:31 Rev Time 0.00
Received By dpalmer Date 2000-08-09 Time 09:31 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO ****************
  
 1)NOTE: LOAD CALCULATIONS NEED TO BE
 COMPLETED. SHOW ALL CONTINUOUS LOADS
 FIGURED AT 125% (LIGHTING,LARGEST MOTOR
 ETC). PLEASE SHOW ALL THE FINAL LOADS
 IN AMPS FOR EACH PANEL AND MDP..
  
 2)NOTE: PLEASE CHANGE COVER SHEET TO
 REFLECT THE "99" NEC.
  
 PLEASE REVISE AND SUBMIT THE ABOVE
 INFORMATION FOR REVIEW BEFORE ROUGH
 ELECTRICAL INSPECTION IS CALLED IN. IF
 THERE ARE ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
  
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-07-25 Cont ID  
Sent By dpalmer Date 2000-07-25 Time 06:13 Rev Time 0.00
Received By dpalmer Date 2000-07-25 Time 06:13 Sent To  
Notes
2001-01-08 00:00:00*************** PROVISO ***************
  
 1)NOTE: SHEET CS-1 SHOWS THE CHANGES TO
 E-1 - E-4. THIS IS OK BUT STILL REF.
 THE 96 NEC. PLEASE HAVE THIS CHANGE
 MADE BEFORE ROUGH ELECTRICAL INSPECTION
 IS CALLED IN.
  
 IF THERE AREANY QUESTIONS PLEASE CALL.
 561 659-8096 EXT 8372
 DEWEY PALMER
 PLAN REVIEW

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-07-06 Cont ID  
Sent By dpalmer Date 2000-07-06 Time 20:13 Rev Time 0.00
Received By dpalmer Date 2000-07-06 Time 20:13 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE SEE THAT COMPLETE SET FOR
 ELECTRICAL IS NOT SUBMITTED. SHEET CS-1
 SHOWS E-1 - E-8?
 SHEET CS-1 AND E-4 ALSO REFERENCES 1996
 NEC AND NO LOCAL AWMENDMENTS.
 WE ARE UNDER 1999 NEC AND HAVE LOCAL
 AMENDMENTS.
  
 PLEASE CORRECT AND CLARIFY THE ABOVE
 INFORMATION. IF THERE ARE ANY QUESTIONS
 PLEASE CALL 561-659-8096 EXT 8372
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-06-19 Cont ID  
Sent By dpalmer Date 2000-06-19 Time 11:09 Rev Time 0.00
Received By dpalmer Date 2000-06-19 Time 11:09 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT *****************
  
 1)NOTE: PLEASE SUBMIT AICRATINGS FOR
 ALL MAINS/PANELS. ALL EQUIPMENT MUST BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110-9/215-5
  
 2)NOTE: PLEASE SUBMIT AND SHOW THE
 ENTIRE LOAD CALCULATION FOR EAACH PANEL
 AND THE MDP/MAIN. PLEASE SHOW ALL LOADS
 THAT ARE CONTINUOUS AT 125%(LIGHTING)ETC
 AND 25% FOR LARGEST MOTOR LOAD.
  
 3)NOTE:PLEASE SHOW THE GROUNDING SYSTEM.
 COLD WATER/EXISTING BLDG. GROUND ATTACH.
 215-5
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL DEWEY PALMER 561-659-8096
 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2000-11-21 Cont ID  
Sent By mcarsill Date 2000-11-21 Time 09:20 Rev Time 0.00
Received By mcarsill Date 2000-11-21 Time 09:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-08-14 Cont ID  
Sent By bstaples Date 2000-08-14 Time 14:54 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00M. CARSILLO REVIEWED 7/13/00 SEE NOTES
 ATTACHED TO PLANS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-06-19 Cont ID  
Sent By bstaples Date 2000-06-19 Time 14:26 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00NOT APPROVED SEE NOTES ATTACHED TO PLANS
 M. CARSILLO 6/14/00.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2000-11-16 Cont ID  
Sent By ndenmark Date 2000-11-16 Time 12:16 Rev Time 0.33
Received By ndenmark Date 2000-11-16 Time 12:16 Sent To  
Notes
2001-01-08 00:00:00NOTE: SEPARATE PERMIT REQUIRED FOR HOOD
 AND SUPPRESSION SYSTEM AND WALK IN COOL-
 ERS AND FREEZERS

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-08-11 Cont ID  
Sent By ndenmark Date 2000-08-11 Time 08:48 Rev Time 0.50
Received By ndenmark Date 2000-08-11 Time 08:48 Sent To  
Notes
2001-01-08 00:00:00PRIOR COMMENTS CORRECTED BY REVISION
 8/11/00

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2000-07-18 Cont ID  
Sent By ndenmark Date 2000-07-18 Time 07:37 Rev Time 1.00
Received By ndenmark Date 2000-07-18 Time 07:37 Sent To  
Notes
2001-01-08 00:00:00*********DENIED*************************
 1) OUTSIDE AIR CALCULATIONS DO NOT
 COMPLY WITH ASHRAE 62-89. EX:
 SMOKING LOUNGE CALLS FOR 60 CFM PER
 PERSON THERE IS NO EQUIVELANT PER SQ FT
 VALUE TO USE. SMOKING DINING @ 20 CFM
 PER PERSON WOULD BE 1160 @ 58 PEOPLE
 AND LOUNGE @ 59 PEOPLE = 3540 CFM TOTAL
 OUTSIDE AIR FOR AC 3 = 4700 CFM. VALUE
 SUPPIED = 2310 CFM NOT PER REQUIREMENT
 PROVIDE OUTSIDE AIR PER ASHRAE 62-89
 2) GREASE EXHAUST DUCT REQUIRES 1" PER
 12" SLOPE TOWARD HOOD MIN. PER 1997 SMC
 505.4 PROVIDE ELEVATION SHOWING SPACE
 AVAIABILITY FOR LENGTH OF RUN

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-06-24 Cont ID  
Sent By ndenmark Date 2000-06-24 Time 10:55 Rev Time 1.00
Received By ndenmark Date 2000-06-24 Time 10:55 Sent To  
Notes
2001-01-08 00:00:00*************DENIED********************
 PLEASE PROVIDE ADDITIONAL INFORMATION
 FOR REVIEW:
 1. PROVIDE OUTSIDE AIR SCHEDULE PER
 ASHRAE 62-89
 2PROVIDE ROOF PLAN SHOWING TERMINATION
 OF GREASE DUCT, OUTSIDE AIR INTAKE, FLUE
 AND RTU'S
 3. PROVIDE DETAIL SHOWING VERTICAL RUN
 OF FLUE, GREASE DUCT, ETC FOR REVIEW
 4. PROVIDE ENERGY EFFICIENCY RATING PER
 ENERGY EFFICIENCY CODE FOR BUILDING
 CONSTRUCTION (STATE OF FLORIDA) 1997 ED
 NOTE: SEPARATE PERMITS REQUIRED FOR HOOD
 COOLERS, FIRE SUPPRESSION. SUBMIT PLANS
 AT TIME OF MECHANICAL PERMIT APPLICATION
 FOR ABOVE

Review Stop P PLUMBING
Rev No 8 Status P Date 2000-11-22 Cont ID  
Sent By jleech Date 2000-11-22 Time 10:54 Rev Time 1.00
Received By jleech Date 2000-11-22 Time 10:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 7 Status F Date 2000-11-17 Cont ID  
Sent By jleech Date 2000-11-17 Time 14:45 Rev Time 1.00
Received By jleech Date 2000-11-17 Time 14:45 Sent To  
Notes
2001-01-08 00:00:00SEAL ALL PAGES.

Review Stop P PLUMBING
Rev No 6 Status P Date 2000-08-11 Cont ID  
Sent By tlarge Date 2000-08-11 Time 14:49 Rev Time 0.65
Received By tlarge Date 2000-08-11 Time 14:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status F Date 2000-08-10 Cont ID  
Sent By tlarge Date 2000-08-10 Time 19:07 Rev Time 2.50
Received By tlarge Date 2000-08-10 Time 19:07 Sent To  
Notes
2001-01-08 00:00:001)A MIN.OF 4 WATER CLOSETS ARE REQD.IN
 THE WOMEN'S RESTROOM PER THE OCCUPANT
 LOAD AND SPC TABLE 407.COMPLY W/FLA.
 STATUTE 553.141(3)POTTY PARITY.
  
 2)WATER SUPPLY CONTROL SHALL COMPLY W/
 SPC SEC.610.4.1,610.4.2.
  
 3)SHT.P-2,P-6-GAS MAIN FROM THE METER
 SHALL BE SIZED 3" PER SGC TABLE 305.4(A)
 YOUR NOTE STATES 3" BUT THE DRAWING IS
 STILL WRONG!
  
 4)ALL FLOOR DRAINS IN TOILET ROOMS SHALL
 BE 3"PER SPC SEC.409.4.1.1.
  
 5)SHT.P-5-VACUUM RELIEF VALVE IS NOT
 LOCATED CORRECTLY.VALVE SHALL BE IN-
 STALLED ON THE WATER SUPPLY OF THE COLD
 WATER,NOT ON THE HOT WATER SIDE.

Review Stop P PLUMBING
Rev No 4 Status F Date 2000-07-27 Cont ID  
Sent By tlarge Date 2000-07-27 Time 19:27 Rev Time 2.75
Received By tlarge Date 2000-07-27 Time 19:27 Sent To  
Notes
2001-01-08 00:00:001)SHT.P-3-ALL FLOOR DRAINS LOCATED IN
 TOILET ROOMS SHALL BE 3" PER SPC SEC.
 409.4.1.1.
  
 2)SHT.P-3-(BAR AREA)-DESIGN OF PLUMBING
 SHALL COMPLY W/SPC SEC.921 FOR WASTE
 AND VENT SYSTEM IF THAT IS THE INTENT.
  
 3)NOTE THE OCCUPANT LOAD ON THE PLANS
 ACCORDING TO THE TOTAL NUMBER OF SEATS
 AND SEATING SPACE AT BOOTHS AND BARS.
 COMPLY W/TABLE 407 OF SPC.SEE SBC TABLE
 1003.1 FOOTNOTE #1 FOR BAR AND BOOTH
 REQS.
  
 4)MINIMUM NUMBER OF REQD.SANITARY
 FACILITIES SHALL BE BASED ON ABOVE REQS.
  
 5)WATER SUPPLY CONTROL SHALL COMPLY W/
 SPC SEC.610.4.1.,610.4.2.
  
 6)SHT.P-6-GAS MAIN FROM METER SHALL BE
 SIZED A MIN.OF 3"PER SGC TABLE 305.4(A).
  
 7)SHT.A1.1-A MIN.OF 4 WATER CLOSETS ARE
 REQD.IN THE WOMEN'S RESTROOM PER SPC
 TABLE 407.ADDITIONAL PLUMBING FIXTURES
 MAY BE REQD.IN BOTH RESTROOMS PENDING
 CORRECT OCCUPANT LOAD COUNT.
  
 8)NUMBER OF SANITARY FACILITIES SHALL
 COMPLY W/FLA.STATUTE 553.141.(POTTY
 PARITY).

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-07-18 Cont ID  
Sent By pschmitz Date 2000-07-18 Time 15:04 Rev Time 3.00
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLUMBING PLAN REVIEW OF REVISIONS
 DATED 06-30-00 GEO SLADEK
 (1) ITEMS #6,#7 SHT P-6 NOT INCLUDED.
 (2) ITEM #11 CO INFO NOT PROVIDED.
 (3) ITEM #13 VACUM RELIEF, WATTS 36-A.
 (4) ITEM #15 MIN FACILITIES SHOW COUNT
 FOR EMPLOYEES & PUBLIC.
 END OF COMMENTS

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-07-11 Cont ID  
Sent By tlarge Date 2000-07-11 Time 12:22 Rev Time 7.50
Received By pschmitz Date 2000-07-11 Time 12:22 Sent To  
Notes
2001-01-08 00:00:00ADDITIONAL PLUMBING FIXTURES ARE REQD.IN
 THE MEN'S AND WOMENS RESTROOMS PER TABLE
 407 OF THE SPC BASED ON NUMBER OF SEATS.
 BATHROOMS SHALL ALSO COMPLY W/FLA.STAT.
 555.141.(POTTY PARITY).
  
 NUMBER AND LOCATION OF PLUMBING FIXTURES
 IN THE MEN'S ROOM ARE NOT TYPICAL
 THROUGHOUT THE PLANS.(TWO URINALS ARE
 SHOWN ON SOME SHEETS AND ONE IS SHOWN ON
 OTHERS.)COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 PLANS STILL SHOW THE VENTS FOR THE FLOOR
 DRAINS OFFSETTING HORIZONTALLY BELOW
 THE SLAB.SHOW COMPLIANCE W/SPC SEC.
 906.2.1.(NOTES ARE NOT ACCEPTABLE.)
  
 SUBMIT COMPLETE GAS RISER DIAGRAM FOR
 REVIEW.SHOW DISTANCE TO MOST REMOTE
 OUTLET,PIPE SIZES,,PIPE MATERIAL,BTU
 LOAD OF EACH APPLIANCE,CALCULATIONS FOR
 COMBUSTION AIR,DETAILS ON VENT AND VENT-
 MATERIALS,ETC...
  
 GAS CONTROLS SHALL COMPLY W/NFPA 5.5.4.
 SHOW COMPLIANCE ON THE GAS RISER.
  
 INSTALLATION OF CLEANOUTS IN THE DRAIN-
 AGE SYSTEM SHALL COMPLY W/SPC SEC.710.2.
  
 VACUUM RELIEF VALVE IS REQUIRED ON THE
 COLD WATER SUPPLY TO THE WATER HEATERS
 PER SPC SEC.507.1.2.(THE PLANS SHOW A
 CHECK VALVE,NOT A VACUUM RELIEF VALVE.)
  
 THE U.L ASSEMBLY NUMBER FOR THE FIRE
 SAFING DETAIL OF PIPE PENETRATIONS SHALL
 BE ON THE PLANS.COUNTYWIDE AMENDMENTS TO
 SPC SEC.104.2.1.
  
 SHT.CS-1-REVISE EDITION OF STANDARD GAS
 CODE TO READ 1997 EDITION.
  
 SHT.CS-1-BUILDING SUMMARY-SANITARY
 FACILITIES CANNOT BE BASED ON 50% MALES
 AND 50% FEMALES.TABLE 407 OF THE SPC
 LISTS SANITARY FACILITIES FOR TOTAL
 PERSONS.
  
 EMPLOYEE TOILET ROOM SHALL BE HANDICAP
 ACCESSIBLE PER FACBC SEC.4.1.3.(11)
  
 FLUSH CONTROLS IN ACCESSIBLE STALLS AND
 TOILET ROOMS SHALL BE LOCATED ON THE
 WIDE SIDE PER FACBC SEC.4.16.5.
  
 CONDENSATE DRAINS CANNOT DISCHARGE TO
 FLOOR SINK.DISPOSAL SHALL COMPLY W/SMC
 SEC.304.8.3.
  
 SHT.P-3-FLOOR SINK SHALL NOT EXCEED
 DISTANCE FROM VENT AS MANDATED IN SPC
 SEC.908.1.(SEE F.S.BY MENS R.R.)
  
 DRY VENTS NOT PERMITTED PER SPC SEC.
 906.2.1.(SEE VENT BY WINE ROOM)

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-06-14 Cont ID  
Sent By tlarge Date 2000-06-14 Time 12:23 Rev Time 6.75
Received By pschmitz Date 2000-06-14 Time 12:23 Sent To  
Notes
2001-01-08 00:00:00SUBMIT OCCUPANT LOAD BASED UPON 40 SQ.
 FT.PER PERSON PER TABLE 407 OF SPC.SEE
 SPC SEC.407.1.3.FOR ALLOWED DEDUCTIBLE
 AREAS.
  
 URINAL IN MEN'S ROOM IS LOCATED IN LINE
 OF SIGHT FROM CORRIDOR.FIXTURES SHALL BE
 SUITABLY SCREENED FOR PRIVACY PER SPC
 404.3.
  
 NUMBER AND LOCATION OF PLUMBING FIXTURES
 ON SHT.PR-1 DOESN'T CORRELATE W/ARCH.
 DRAWINGS.CLARIFY.COUNTYWIDE AMENDMENTS
 TO SPC 104.2.1.
  
 DISHWASHER SHALL DISCHARGE TO THE
 SANITARY SYSTEM PER CITY OF WEST PALM
 BEACH ORDINANCE.
  
 INDICATE IF GREASE TRAP/GREASY WASTE
 SYSTEM IS NEW OR EXISTING.SUBMIT DETAILS
 ON GREASE TRAP.GREASE RECOVERY UNITS ARE
 NOT PERMITTED.SPC 1004.2
  
 INDIRECT WASTES SHALL DISCHARGE TO FLOOR
 SINKS PER 807.1.2, 807.1.3.
  
 THE DISCHARGE FROM ALL SINKS,INDIRECT
 WASTES,ETC.(EXCEPT THE DISHWASHER)SHALL
 DISCHARGE TO THE GREASY WASTE SYSTEM.
 SPC SEC.1004.4
  
 SUBMIT APPROVAL FROM CITY OF WPB
 UTILITIES FOR GREASE TRAP.
  
 2-WAY CLEANOUTS ARE REQD.ON THE INLET
 AND OUTLET OF THE GREASE INTERCEPTOR PER
 SPC SEC.710.4.
  
 SHT.P-3-VENTS FOR FLOOR DRAINS SHALL
 6"ABOVE FLOOD LEVEL RIM PRIOR TO OFF-
 SETTING HORIZONTALLY PER SPC SEC.906.2.1
  
 SUBMIT COMPLETE GAS RISER DIAGRAM FOR
 REVIEW.SHOW DISTANCE TO MOST REMOTE
 OUTLET,PIPE SIZES,PIPE MATERIAL,BTU LOAD
 OF EACH APPLIANCE, ETC.COMPLY W/SGC SEC.
 305.4.
  
 GAS CONTROLS SHALL COMPLY W/NFPA 54 SEC.
 5.5.4.
  
 LOCATION OF GAS VALVES FOR EQUIPMENT
 SHALL BE READILY ACCESSIBLE PER SGC SEC.
 310.1.
  
 PLEASE SUBMIT A LEGIBLE AND EXPANDED
 SANITARY ISOMETRIC FOR REVIEW.(SEE REST-
 ROOM AREAS.)COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 BACKFLOW PREVENTERS ARE REQD.ON THE
 CARBONATION EQUIP PER SPC SEC.606.1.
  
 SHT.P-6-NOTE #8-INSTALLATION OF CLEAN-
 OUTS IN THE DRAINAGE SYSTEM SHALL COMPLY
 W/SPC SEC.710.2.4.
  
 SUBMIT MANUF.SHEETS FOR COMPONENTS OF
 THE 2# SYSTEM.SGC SEC.1006.
  
 A VACUUM RELIEF VALVE IS REQD.ON THE
 COLD WATER SUPPLY TO THE WATER HEATERS
 PER SPC SEC.507.1.2.
  
 SUBMIT U.L. ASSEMBLY NUMBER FOR FIRE
 SAFING DETAIL OF PIPE PENETRATIONS THRU
 RATED WALLS.COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.4.
  
 NUMBER OF REQUIRED SANITARY FACILITIES
 SHALL COMPLY W/FLA.STATUTE 553.141.
 (POTTY PARITY)