Plan Review Details - Permit 00060357
| Plan Review Stops For Permit 00060357 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-12 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-07-12 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-08-01 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-31 |
Time |
18:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-22 |
Time |
19:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-22 |
Time |
19:24 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************UNSAT ******************** | | | | | | 1)NOTE: PLEASE SEE E3.1. MISSING BRANCH | | | CIRCUIT # FOR OUTLETS.(PETER`S OFFICE) | | | | | | 2)NOTE: SUBMIT LOAD CALCULATION FOR | | | EACH PANEL. YOU SHOW THE SAME LOAD ON | | | EACH PANEL? PLEASE NOTE THAT CONTINUOUS | | | LOADS ARE FIGURED AT 125% (LIGHTING) | | | PLEASE GIVE A BREAKDOWN ON CALCS. | | | OUTLETS, SQ.FT ETC. | | | | | | 3)NOTE: PANEL 'H8A' SHOWS AIC RATING | | | AT 14,000? THIS DOES NOT CORRELATE WITH | | | STANDARD RATINGS OF EQUIPMENT. PLEASE | | | CHECK. | | | | | | 4)NOTE: PLEASE INDICATE ON PLANS THE | | | MAIN DISCONNECT SIZE FOR THIS SPACE. | | | IS IT THE SAME AS THE ON SHOWN FOR SMITH | | | BARNEY? | | | | | | 5)PLEASE SHOW PANEL SCHEDULES SHOWING | | | CIRCUITS AS LIGHTING CIRCUITS TO CORRE- | | | -LATE WITHROOM #S. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORAMTION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-07-14 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-07-14 |
Time |
10:40 |
Rev Time |
0.30 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-06-21 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-06-21 |
Time |
10:30 |
Rev Time |
0.30 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVIDE FIRE SPRINKLER DRAWINGS. | | | PROVIDE DIRECTIONAL EXIT LIGHTS IN | | | CORRIDOR W/I SPACE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-07-31 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-31 |
Time |
16:06 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-31 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NOTES: | | | REVISION COMPLIED AS PER REVIEW DONE ON | | | 07.18.00..... |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-07-18 |
Time |
19:37 |
Rev Time |
1.00 |
| Received By |
cthirben |
Date |
2000-07-18 |
Time |
19:31 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | REVIEW ON 06.24.00 REQUIRES FIRE DAMPERS | | | AT FIRE RATED WALLS. RESUBMITTED PLAN | | | RESPONSE LETTER STATES THAT SHEET M7.2 | | | THE INFO.THERE IS NO SHEET M7.2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-06-24 |
|
|
Cont ID |
|
| Sent By |
cthirben |
Date |
2000-06-24 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
cthirben |
Date |
2000-06-24 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED: | | | PROVIDE DETAILS FOR DAMPERS ATFIRE | | | RATED WALLS PENETRATION OF DUCT FOR | | | THE EXHAUST FAN AND SUPPLY DUCT. 1997 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-06-17 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-06-17 |
Time |
12:34 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PROVISO | | | (1) SEE SHT A-3 COMPLY WITH FACBC | | | 4.1.3 (11) HANDI-CAP ADAPTABEL. |
|
|
|