Plan Review Details - Permit 00060122
Plan Review Stops For Permit 00060122
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-09-20 Cont ID  
Sent By lmartine Date 2000-09-20 Time 16:59 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-07-19 Cont ID  
Sent By lmartine Date 2000-07-19 Time 16:53 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-07-03 Cont ID  
Sent By lmartine Date 2000-07-03 Time 14:40 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00*******************
 BUILDING REVIEW
 *******************
  
 1]SUBMIT COUNTY IMPACT FEE RECEIPT,
 REQUIRED WHEN CHANGING OCCUPANCY USE.
 2]DOOR D01 IS NOT ACCESSSIBLE,ONE LEAF
 SHALL PROVIDE 32" CLEAR,SEE 4.13.4 AND
 4.13.5,FAC97,DOOR D07 SHALL COMPLY
 WITH 4.3.8 {MAXIMUM LEVEL CHANGE 1/2"]
 IS DOOR #D07 3'OR 5' WIDE?
 3]WINDOW IN BEDROOM SHALL MEET EMERGENCY
 EGRESS,SUBMIT PRODUCT TESTING FOR ANY
 NEW EXTERIOR WINDOWS AND DOORS.
  
  
  
 BUILDING REVIEW PERFORMED BY;
 LUIS MARTINEZ 561-659-8096#8456

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-09-25 Cont ID  
Sent By dpalmer Date 2000-09-25 Time 13:10 Rev Time 0.00
Received By dpalmer Date 2000-09-25 Time 13:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-09-01 Cont ID  
Sent By dpalmer Date 2000-09-01 Time 12:53 Rev Time 0.00
Received By dpalmer Date 2000-09-01 Time 12:53 Sent To  
Notes
2001-01-08 00:00:00************** UNSAT *******************
  
 1)NOTE: NOTES FROM PROVISO ON FIRST
 REVIEW NOT ADDRESSED. PLEASE DO SO AND
 RE-SUBMIT FOR REVIEW.
  
 PLEASE SUBMIT ALL THE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-06-06 Cont ID  
Sent By dpalmer Date 2000-06-06 Time 19:21 Rev Time 0.00
Received By dpalmer Date 2000-06-06 Time 19:21 Sent To  
Notes
2001-01-08 00:00:00O************* PROVISO *****************
  
 1)NOTE: PLEASE SUBMIT PLANS WITH ALL
 BRANCH CIRCUIT #`S SHOWN. 215-5
  
 2)NOTE: PLEASE DO A RECOUNT ON OUTLETS
 PER 220-13
  
 3)NOTE: PLEASE NOTE THAT PANEL SCHEDULE
 SHOWS MLO, AND RISER DIAGRAM SHOWS MCB?
 PLEASE CORRELATE. 215-5
  
 4)NOTE:PLEASE CHECK THE REQ`MENTS OF ART
 220-12-B FOR LOAD CALCULATIONS OF TRACK
 LIGHTING.
 ALSO PLEASE NOTE 125% FOR CONTINUOUS
 LOADS (LIGHTING). PLEASE REFIGURE LOAD
 CALCULATIONS TO REFLECT.
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORAMTION
 FOR REVIEW. PLEASE SUBMIT FOR REVIEW
 BEFORE ANY ROUGH ELECTRICAL INSPECTION
 IS CALLED IN. IF THERE ARE ANY QUESTIONS
 PLEASECALL 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-06-23 Cont ID  
Sent By rturnque Date 2000-06-23 Time 10:57 Rev Time 0.20
Received By rturnque Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-09-01 Cont ID  
Sent By ndenmark Date 2000-09-01 Time 10:22 Rev Time 0.25
Received By ndenmark Date 2000-09-01 Time 10:22 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 1. DUCT SMOKE DETECTOR REQUIRED FOR FAN
 SHUT DOWN
 2. NOTIFICATION OF FAN SHUT DOWN REQUIRE
 PER NFPA 4-4.4
 3.OVERFLOW PROTECTION REQUIRED FOR AHU
 4.COND. UNIT TO BE ON SOLID CONCRETE PAD
 MIN. 3' ABOVE FINISHED GRADE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-06-28 Cont ID  
Sent By cthirben Date 2000-06-28 Time 11:03 Rev Time 1.00
Received By cthirben Date 2000-06-28 Time 11:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-08-06 Cont ID  
Sent By tlarge Date 2000-08-06 Time 08:36 Rev Time 0.33
Received By tlarge Date 2000-08-06 Time 08:31 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).PROVISIONS SHALL BE
 MADE FOR PEOPLE WHO HAVE TROUBLE BENDING
 OR STOOPING.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-07-12 Cont ID  
Sent By tlarge Date 2000-07-12 Time 08:54 Rev Time 0.50
Received By tlarge Date 2000-07-12 Time 08:49 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
 A DRINKING FOUNTAIN IS REQD.PER SPC SEC.
 407.FOUNTAIN SHALL COMPLY W/FACBC SEC.
 4.1.3.(10)(A).PROVISIONS SHALL BE MADE
 FOR PEOPLE WHO HAVE TROUBLE BENDING OR
 STOOPING.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-06-14 Cont ID  
Sent By tlarge Date 2000-06-14 Time 17:52 Rev Time 0.65
Received By tlarge Date 2000-06-14 Time 17:52 Sent To  
Notes
2001-01-08 00:00:00THIS APPEARS TO BE A CHANGE OF OCCUPANCY
 FROM R-3 TO B.FULL COMPLIANCE W/FACBC
 IS REQUIRED PER FACBC SEC.4.1.6.SHOW
 COMPLIANCE ON PLANS.
  
 SINK SHALL COMPLY W/FACBC SEC.4.24.1-
 4.24.7.
  
 SUBMIT WATER RISER DIAGRAM FOR REVIEW.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 SHOW SQUARE FOOTAGE OF STRUCTURE ON PLAN
 ADDITIONAL TOILET FACILITIES MAY BE
 REQUIRED PER SPC TABLE 407.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-06-06 Cont ID  
Sent By gjoyce Date 2000-06-06 Time 09:27 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***