| Plan Review Stops For Permit 00051573 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-07-05 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-10-05 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-10-05 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-13 |
Time |
20:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-13 |
Time |
20:52 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE PROVIDE MORE DETAIL FOR | | | TOTAL SCOPE OF ELECTICAL WORK ON THIS | | | PERMIT. YOU ARE REFERENCING OTHER EE- | | | SHEETS ON THESE PLANS? NO OTHER SHEETS | | | ARE ATTACHED? YOU ARE ALSO SHOWING | | | TEMPORARY TRAILERS TO BE FED? IS THERE | | | DETAILS ON THIS OR IS THIS FOR FUTURE?? | | | IS THIS GOINGTO BE JUST FOR UNDER- | | | --GROUND PIPES? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2000-10-16 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-10-16 |
Time |
14:39 |
Rev Time |
2.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | APPROVED | | | LATEST PLAN APPROVED BY HEALTH DEPT. | | | WITH LAST REVISION DATRE 8/17/00 | | | | | | IF SITE WILL HAVE GABAGE THAT THE CITY | | | WILL PICK UP THEN PLEASE CALL FOR | | | MINIMUM DUMPSTER DIMENSION. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2000-06-22 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-06-22 |
Time |
13:06 |
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | COMMENTS: | | | PRIVATE 4" WM IS TOO CLOSE TO 8" WM | | | PLEASE REFER TO PLAN FOR PREFERED LOCA- | | | TION. | | | PROVIDE HANDICAP RAMP ON SHEET PARK-EB1 | | | RESUBMITPLANS TO PUBLIC UTILITIES | | | FOR FINAL APPROVAL. | | | (2 SETS REQUIRED) | | | SHEET C-EB6 CALLS OUT TEES AS BEING | | | 8"X2" CONNECTING TO A 4" WM. | | | PLEASE CLARIFY. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-10-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-18 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-18 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) FIRE HYDRANTS WHEN INSTALLED ARE NOT | | | TO EXCEED 500 FEET BETWEEN THEM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2001-01-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-23 |
Time |
14:36 |
Rev Time |
2.50 |
| Received By |
jleech |
Date |
2001-01-23 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-01-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-23 |
Time |
09:47 |
Rev Time |
2.00 |
| Received By |
jleech |
Date |
2001-01-23 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2001-01-23 00:00:00 | DENIED; | | | | | | 1.CLOUD CHANGES AND ADDITIONS. | | | | | | 2.SPECIFY TYPE OF PIPE TO BE USED. | | | | | | 3.ADDITIONAL PERMIT FEES REQUIRED FOR | | | ADDITIONAL WORK TO BE DONE. | | | | | | 4.WELL WATER PIPING MUST BE CODED TO | | | COMPLY TO 94 SPC SEC. 605.SHOW ON | | | DRAWINGS. | | | | | | ANY QUESTIONS CALL | | | JOHN LEECH | | | 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-10-14 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-14 |
Time |
05:40 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-10-14 |
Time |
05:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************PROVISO***************** | | | SUBMIT COPIES OF APPROVALS FROM DEPT.OF | | | ENVIRONMENTAL PROTECTION AND PALM BEACH | | | COUNTY HEALTH DEPT.FOR THE WATER SYSTEM. | | | | | | ****NOTE:THIS REVIEW IS FOR THE WEST | | | SIDE INFRASTRUCTURE ONLY!!!!! | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | | QUESTIONS.LANS EXAMINER. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-10-07 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-07 |
Time |
11:03 |
Rev Time |
2.00 |
| Received By |
tlarge |
Date |
2000-10-07 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)THE PLANS STILL NOTE"PROPOSED WATER | | | WELL,REMOVAL OFGAS MAIN AND INSTALL- | | | ATION OF NEW PIPING,AND REMOVAL AND | | | INSTALLATION OF WATER,SEWER AND STORM | | | LINES".YOUR RESPONSE NOTES THIS WORK IS | | | NOT TO BE DONE UNDER THIS PERMIT.CLARIFY | | | | | | 2)SUBMIT COPIES OF PERMITS FROM THE | | | DEPT. OF ENVIRONMENTAL PROTECTION AND | | | THE PALM BEACH COUNTY HEALTH DEPT.FOR | | | THE WATER SYSTEM.COUNTYWIDE AMENDMENTS | | | TO SPC SEC.101.4.7. | | | | | | 3)SUBMIT ADDITIONAL INFORMATION FOR THE | | | GAS SYSTEM TO BE INSTALLED.(TYPE OF | | | PIPING,JOINING METHOD,DELIVERY PSI,ETC.) | | | | | | 4)INSTALLATION OF GAS PIPING SHALL | | | COMPLY W/SGC SEC.309.10.309.13 AND NFPA | | | 54. | | | | | | 5)SHT.EB-7 REFERS TO ARCH.PLANS FOR | | | DETAIL OF GREASE TRAP.ARCH.PLANS ARE NOT | | | WITH THIS PACKAGE.SUBMIT FOR REVIEW. | | | | | | 6.)SUBMIT ADDITIONAL INFORMATION FOR THE | | | GREASE TRAP.CONTACT R.COMPO AT CITY OF | | | WPB UTILITIES.561-835- 7423. | | | | | | CALL 561-659-8096,EXT,8377 IF YOU HAVE | | | QUESTIONS. | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-08 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-08 |
Time |
12:36 |
Rev Time |
1.75 |
| Received By |
tlarge |
Date |
2000-06-08 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SUBMIT PLANS ONLY FOR THE WORK TO BE | | | DONE UNDER THIS PERMIT.COUNTYWIDE AMEND- | | | MENTS TO SPC SEC.104.2.1. | | | | | | PLANS SHOW PROPOSED WATER WELL,REMOVAL | | | OF EXISTING GAS MAIN AND INSTALLATION OF | | | NEW GAS MAIN,DRAINS AND PIPING AT | | | ORIENTATION AREA,ETC.INDICATE IF THIS | | | WORK WILL BE DONE UNDER THIS PERMIT. | | | | | | A PERMIT FROM THE DEPT.OF ENVIRONMENTAL | | | PROTECTION AND ALSO THE PALM BEACH | | | COUNTY HEALTH DEPT.FOR THE WATER SYSTEM. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.101.4.7 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-04 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-06-06 |
Time |
10:09 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NEEDS LANDSCAPE PLAN, LIGHTING PLAN | | | PARKING DOES NOT MEET CODE | | | GVE TO J. MCELHENY 9-19-00 |
|
|