| Plan Review Stops For Permit 00051555 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-07-06 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-07-06 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-08 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-08 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-11-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-29 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-29 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-07-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-07-25 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-07-25 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-06-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-06-19 |
Time |
20:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-06-19 |
Time |
20:03 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ****************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT | | | `#`S ON PLANS INCLUDE ALL RECEPT. CIR.`S | | | AND LIGHITNG. 215-5 | | | | | | 2)NOTE: PLEASE SHOW LIGHTING LOADS FIG- | | | -URED AT 125% FOR CONTINUOUS LOAD. | | | PLEASE SHOW IN CLACULATION. | | | | | | 3)NOTE: PANEL EDP SHOWS FEED TO PANEL | | | 'ELP'? NOT SHOWN ON LINE DIAGRAM. | | | | | | EEEETE: PLEASE NOTE THAT AIC RATING OF | | | PANEL 'H5B' IS SHOWN AT 14,000? PLEASE | | | CALRIFY THIS AS A STANDARD RATING. | | | | | | 5)NOTE: PLEASE CHECKLINE DIAGRAM | | | | | | FOR WIRE SIZING. MIGHT BE A TYPE-O FOR | | | MAINS? YOU SHOW #10, PLEASE CHANGE TO | | | 1/0. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL 561-659-8096 EXT 8372 | | | DEWEY PALMER ELECTRICAL PLAN REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-05-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-16 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-16 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-03-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-29 |
Time |
12:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-29 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-28 |
Time |
08:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-28 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-06-08 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2000-06-08 |
Time |
14:18 |
Rev Time |
0.25 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-03-15 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-03-15 |
Time |
12:45 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2001-03-15 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2001-03-15 00:00:00 | AS BUILT REVISION DATED 2/28/01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-07-13 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-07-13 |
Time |
09:46 |
Rev Time |
0.10 |
| Received By |
ndenmark |
Date |
2000-07-13 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
A |
Date |
2000-07-13 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-06-24 |
Time |
10:09 |
Rev Time |
1.00 |
| Received By |
ndenmark |
Date |
2000-06-24 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ACCEPTED/CORRECTED BY REVISION7/13/00* | | | 1. SCU-5 SHOWS AS SOURCE OF O/A AND COND | | | ITIONED AIR FOR SPACE SHOW LOCATION AND | | | CONECTION TO DUCTS IN SPACE | | | 2. HPU-1 SHOWS 140 CFM OF OUTSIDE AIR. | | | PROVIDE DETAILS OF O/A CONNECTION TO HPU | | | 3. SHOW EXISTING DUCT LOCATION SOURCE OF | | | CONDITIONED AIR FOR DISTRIBUTION EX: | | | M2.1 SHOWS 15" ROUND DUCT WHERE DOES IT | | | COME FROM? | | | M2.2 SHOWS 3 DUCTS 18" ROUND,17" ROUND, | | | AND A 14" ROUND. WHERE DO THEY COME FROM | | | 4. PROVIDE DUCT AND INSULATION SPECIFI- | | | CATIONS FOR AIR DISTRIBUTION COMPONENTS. | | | 5. PROVIDE AIR BALANCE SCHEDULE TO SHOW | | | COMPLIANCE WITH 1997 SMC 501.2 | | | | | | INSUFFICIENT INFORMATION PROVIDED FOR | | | REVIEW. PROVIDE ABOVE INFORMATION AND | | | RESUBMIT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-05-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-05-11 |
Time |
10:05 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2001-05-11 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-07-26 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-07-26 |
Time |
12:25 |
Rev Time |
2.25 |
| Received By |
tlarge |
Date |
2000-07-26 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *****************PROVISO**************** | | | WIDTH OF DOOR OPENING TO TOILET ROOM # | | | 523 SHALL BE MIN.32"CLEAR SPACE PER | | | FACBC SEC.4.13.5 | | | | | | 2)PROVIDE WOOD BLOCKING IN TOILET ROOM | | | #523 FOR FUTURE INSTALLATION OF GRAB | | | BARS PER FACBC SEC.4.1.3(11). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-06-04 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-06-04 |
Time |
09:18 |
Rev Time |
0.75 |
| Received By |
tlarge |
Date |
2000-06-04 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PRIVATE TOILET(ROOM #523)SHALL BE | | | HANDICAP ADAPTABLE PER FACBC SEC.4.1.3. | | | (11).PROVIDE DETAILS FOR WOOD BLOCKING | | | FOR FUTURE INSTALLATION OF GRAB BARS. | | | | | | WATER CLOSET SHALL BE 18"FROM FINISH | | | WALL TO CENTER OF TOILET PER FACBC FIG. | | | 28. | | | | | | LOCATION OF WATER CLOSET IN TOILET ROOM | | | SHALL NOT INTERFERE W/NORMAL OPERATION | | | OF DOOR.SPC SEC.404.2. | | | | | | SINK IN BREAK ROOM SHALL COMPLY W/FACBC | | | SEC.4.24.1-4.24.7. | | | | | | DOOR OPENING TO TOILET ROOM SHALL COMPLY | | | W/FACBC SEC.4.13.5. | | | | | | SUBMIT SQUARE FOOTAGE OF OCCUPIED SPACE. | | | NUMBERAND TYPE OF MIN.REQD.SANITARY | | | FACILITIES SHALL COMPLY W/SPC TABLE 407. |
|
|