Plan Review Details - Permit 00051311
Plan Review Stops For Permit 00051311
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2000-11-17 Cont ID  
Sent By hpiskura Date 2000-11-17 Time 11:08 Rev Time 99.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2000-11-14 Cont ID  
Sent By hpiskura Date 2000-11-14 Time 12:12 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-01-08 00:00:003RD CKLST W/ APPLICATION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-10-25 Cont ID  
Sent By hpiskura Date 2000-10-25 Time 11:41 Rev Time 0.00
Received By hpiskura Date 2000-10-24 Time 07:15 Sent To  
Notes
2001-01-08 00:00:00LETTER W APPLICATION

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-07-10 Cont ID  
Sent By hpiskura Date 2000-07-10 Time 13:55 Rev Time 0.00
Received By hpiskura Date   Time   Sent To Z
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2001-10-22 Cont ID  
Sent By dpalmer Date 2001-10-22 Time 20:51 Rev Time 0.00
Received By dpalmer Date 2001-10-22 Time 20:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2001-10-11 Cont ID  
Sent By dpalmer Date 2001-10-11 Time 10:29 Rev Time 0.00
Received By dpalmer Date 2001-10-11 Time 10:29 Sent To  
Notes
2001-10-11 00:00:00LETTER SUBMITTALS ONLY.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-10-05 Cont ID  
Sent By dpalmer Date 2001-10-05 Time 10:51 Rev Time 0.00
Received By dpalmer Date 2001-10-05 Time 10:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-10-05 Cont ID  
Sent By dpalmer Date 2001-10-05 Time 07:28 Rev Time 0.00
Received By dpalmer Date 2001-10-05 Time 07:28 Sent To  
Notes
2001-10-05 00:00:00REV FOR TWO SHEETS ONLY.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-10-01 Cont ID  
Sent By dpalmer Date 2001-10-01 Time 09:35 Rev Time 0.00
Received By dpalmer Date 2001-10-01 Time 09:35 Sent To  
Notes
2001-10-01 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT NOT ALL SHEETS
 SIGNED. 471.025
 PLEASE ALSO NOTE THAT THERE ARE THREE
 DIFFERENT SIGNATURES ON PLANS FOR
 ELECTRICAL ENGINEER. PLEASE CALRIFY!
 PLEASE HAVE ENGINEER OF RECORD SIGN
 HIS SEALED DOCUMENTS.471.025
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW. IF
 THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-10-31 Cont ID  
Sent By dpalmer Date 2000-10-31 Time 13:36 Rev Time 0.00
Received By dpalmer Date 2000-10-31 Time 13:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-06-23 Cont ID  
Sent By dpalmer Date 2000-06-23 Time 10:24 Rev Time 0.00
Received By dpalmer Date 2000-06-23 Time 10:24 Sent To  
Notes
2001-01-08 00:00:00 
 ***************** UNSAT ****************
  
 LOAD CALCULATIONS AT THE BOTTOMOF EACH
 PANEL NOT COMPLETED INCLUDING MAINS.
 SEE PERMIT #00051322

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-10-01 Cont ID  
Sent By mcarsill Date 2001-10-01 Time 15:14 Rev Time 0.00
Received By mcarsill Date 2001-10-01 Time 15:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-09-28 Cont ID  
Sent By mcarsill Date 2000-09-28 Time 14:09 Rev Time 0.00
Received By mcarsill Date 2000-09-28 Time 14:09 Sent To  
Notes
2001-01-08 00:00:001) BUILDING ADDRESS NOT SHOWN ON
 ELEVATION DRAWINGS. BUILDING ADDRESSES
 TO COMPLY WITH CITY CODE REQUIREMENTS.
 2) PLEASE CONTACT THE FIRE PREVENTION
 BUREAU AT 835-2910 TO REQUEST KNOX-BOX
 APPLICATION(S) FOR THE BUILDINGS.
 3) ELEVATORS TO COMPLY WITH ANSI A17.1
 AND THE UNIFORM FIRE CODE FOR ELEVATORS
 4A-47.
 4) INTERIOR FINISHES IN EXITS TO BE
 CLASS A OR B. INTERIOR FINISHES IN
 OFFICES TO BE CLASS A, B, OR C.
 5) PLEASE PROVIDE FIRE ALARM SYSTEM SHOP
 DRAWINGS FOR FIRE ALARM EQUIPMENT SHOWN
 ON DRAWINGS. CUT SHEETS REQUIRED ON
 ALL DEVICES PLANNED FOR USE.
 6) FIRE ALARM SYSTEM AND FIRE SPRINKLER
 SYSTEM TO BE MONITORED BY A UL LISTED
 CENTRAL STATION APPROVED BY THE FIRE
 RESCUE DEPARTMENT.
 7) EXIT DOORS 113 AND 116 WHEN OPENED
 ARE NOT TO INTERFERE WITH ONE ANOTHER.
 8) EXIT DOORS WHEN OPENED ARE NOT TO
 PROJECT MORE THAN SEVEN INCHES INTO
 A REQUIRED EXIT CORRIDOR.
 9) ALL STAIRS TO COMPLY WITH NEW STAIRS
 PER NFPA 101, THE LIFE SAFETY CODE,
 1985 EDITION.
 APPROVED PROVISO:

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-06-15 Cont ID  
Sent By rturnque Date 2000-06-15 Time 11:47 Rev Time 1.30
Received By rturnque Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVIDE FIRE SPRINKLER DRAWINGS.
 FIRE ALARM SYSTEM SHALL BE CLASS "A" OR
 ADDRESSABLE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-09-27 Cont ID  
Sent By pkrauss Date 2001-09-27 Time 08:30 Rev Time 0.50
Received By pkrauss Date 2001-09-27 Time 07:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-06-26 Cont ID  
Sent By ndenmark Date 2000-06-26 Time 14:53 Rev Time 1.00
Received By ndenmark Date 2000-06-26 Time 14:53 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 MODEL COUNTYWIDE AMENDMENTS AS ADOPTED
 BY THE CITY OF WEST PALM BEACH REQUIRES
 EQUIPMENT MOUNTED ON ROOF STANDS TO HAVE
 A MINIMUM OF 18" CLEARANCE BETWEEN ROOF
 SURFACE AND THE BOTTOM OF THE SUPPORT
 STRUCTURE OF THE STAND

Review Stop P PLUMBING
Rev No 5 Status P Date 2001-10-10 Cont ID  
Sent By kstevens Date 2001-10-10 Time 09:28 Rev Time 0.50
Received By kstevens Date 2001-10-10 Time 09:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2001-09-27 Cont ID  
Sent By kstevens Date 2001-09-27 Time 11:59 Rev Time 0.50
Received By kstevens Date 2001-09-27 Time 11:59 Sent To  
Notes
2001-09-27 00:00:00DENIED
 REFERENCE: SPC-94
  
 PAGE P6-1 WATER HAMMER ARRESTORS TO BE
 INSTALLED PER MANUFACTURE INSTALLATION
 INSTRUCTIONS AND WH-PDI 201 AND NOT AT
 THE TOP OF THE DROPS AS SHOWN ON DOMES-
 TIC WATER ISOMETRIC. PLEASE SHOW PROPER
 LOCATION ON PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-11-14 Cont ID  
Sent By jleech Date 2000-11-14 Time 08:51 Rev Time 1.50
Received By jleech Date 2000-11-14 Time 08:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-09-26 Cont ID  
Sent By tlarge Date 2000-09-26 Time 18:45 Rev Time 3.50
Received By tlarge Date 2000-09-26 Time 16:14 Sent To  
Notes
2001-01-08 00:00:001)SITE PLAN-SHT.5-WATER SERVICE IS SHOWN
 AS 2 1/2" INCH AND ALSO AS 3".CLARIFY.
  
 2)PLEASE NOTE THE OCCUPANT LOAD ON THE
 PLANS PER SPC TABLE 407.SEE SPC SEC.
 407.1.3.FOR ALLOWED DEDUCTIBLE AREAS.
 SHOW THE CALCULATIONS ON THE PLAN.
  
 3)SHT.A-4-IDENTIFY THE HANDICAP URINAL
 ON THE PLANS.THE STALL DOOR CANNOT
 SWING INTO THE CLEAR FLOOR SPACE FOR THE
 URINAL PER FACBC SEC.4.17.5.
  
 4)SHT.A-8-PLEASE CLARIFY SECONDARY
 DRAINAGE CALCULATIONS.SEE APPENDIX "A"
 IN THE SPC FOR SCUPPER SIZING.
  
 5)DELETE REFERENCE TO SFBC AT SAND/OIL
 INTERCEPTOR.SHT.P0-1.
  
 6)SHT.P5-1-MAX.NUMBER OF FIXTURE UNITS
 ON 3" HORIZONTAL BRANCH CONNECTED TO THE
 BUILDING DRAIN SHALL NOT EXCEED 20 F.U'S
 PER TABLE 714.1.(SEE U/G BRANCH FOR LAV.
 WASTE STACKS.)
  
 7)THE SQ.FOOTAGE DRAINED BY THE ROOF
 DRAINS SHOWN ON SHT.P2.1 DOESN'T
 CORRELATE W/SHT.P5-1.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-06-12 Cont ID  
Sent By tlarge Date 2000-06-12 Time 16:43 Rev Time 3.00
Received By tlarge Date 2000-06-12 Time 16:43 Sent To  
Notes
2001-01-08 00:00:00SUBMIT COPY OF JOB SPECIFICATIONS FOR
 REVIEW.COUNTYWIDE AMENDMENTS TO SPC SEC.
 104.2.1.
  
 AN ADDITIONAL LAVATORY IS REQD.IN THE
 WOMEN'S RESTROOM PER TABLE 407.(REQD.IN
 ON ALL FLOORS.)
  
 SUBMIT STORM DRAINAGE AND CONDENSATE
 ISOMETRICS FOR REVIEW.COUNTYWIDE AMEND-
 MENTS SEC.104.2.1.
  
 SHOW HEIGHT DIMENSION FOR SCUPPER ON
 DETAIL #12 AND SUBMIT DETAILS FOR OVER-
 FLOW DRAINAGE FOR HIGH ROOF AREA.COMPLY
 W/SPC SEC.1109.1,1109.2,1109.3.
  
 SHT.A-15-SHOW MOUNTING HEIGHT OF ALL
 HANDICAP ACCESSIBLE FIXTURES AND
 APPURTENANCES.SHOW CLEAR FLOOR SPACE
 UNDER FIXTURES TO FINISH FLOOR.COMPLY W/
 FACBC OCT.1997 EDITION.
  
 SHT.P-4-LOCATION OF VTR'S SHALL COMPLY
 COMPLY W/SPC SEC.905.5.
  
 SHT.P-5-SIZE THE SOIL STACKS FOR W.C.'S
 IN THE WOMEN'S R.R.COMPLY W/SPC TABLE
 714.2.
  
 SIZE THE HORIZ.BRANCH FOR THE LAVS.
 COMPLY W/SPC TABLE 714.1.(DOUBLE LAVS.)
 SHOW SLOPE OF PIPE.
  
 SHT.P6-1-3/4"WATER LINE TO MOP SINKS
 SUPPLIED BY 1/2" LINE.SPC 607.1,607.4.

Review Stop Z ZONING
Rev No 4 Status P Date 2001-10-05 Cont ID  
Sent By sgraham Date 2001-10-05 Time 11:36 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2001-10-01 Cont ID  
Sent By sgraham Date 2001-10-01 Time 10:39 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2001-09-26 Cont ID  
Sent By sgraham Date 2001-09-26 Time 13:16 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-09-26 00:00:00DENIED BY ZONING-8-REQUIRED HC SPACES
 ONE SPACE HAS PERSON EXITING BEHIND THE
 CAR, THIS IS NOT ALLOED

Review Stop Z ZONING
Rev No 1 Status P Date 2000-11-20 Cont ID  
Sent By hpiskura Date 2000-07-10 Time 13:57 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***