Plan Review Details - Permit 00051293
Plan Review Stops For Permit 00051293
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-10-10 Cont ID  
Sent By dpalmer Date 2000-10-10 Time 15:36 Rev Time 0.00
Received By dpalmer Date 2000-10-10 Time 15:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-06-06 Cont ID  
Sent By dpalmer Date 2000-06-06 Time 17:57 Rev Time 0.00
Received By dpalmer Date 2000-06-06 Time 17:57 Sent To  
Notes
2001-01-08 00:00:00*********** NOTE**********************
  
 NOTES REDLINED ON PLANS FOR MISSING
 KITCHEN COUNTERTOP OUTLET.210-52-C-1
 MISSING GFI FOR 210-52E
 MISSING EGRESS LIGHTING 210-70
 NOTE FOR 210-11-C-3 FOR BATH CIRCUIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2000-10-07 Cont ID  
Sent By jleech Date 2000-10-07 Time 09:03 Rev Time 0.25
Received By jleech Date 2000-10-07 Time 09:03 Sent To  
Notes
2001-01-08 00:00:00NO A/C PLANS;
 SUBMIT A/C DRAWING WITH A/C
 APPICATION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-06-08 Cont ID  
Sent By cthirben Date 2000-06-08 Time 09:10 Rev Time 1.00
Received By cthirben Date 2000-06-08 Time 09:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-02-15 Cont ID  
Sent By pschmitz Date 2001-02-15 Time 08:44 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-02-15 00:00:00REVISION DENIED,SHOW AS BUILT.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-06-07 Cont ID  
Sent By tlarge Date 2000-06-07 Time 20:03 Rev Time 0.33
Received By tlarge Date 2000-06-07 Time 20:03 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2000-12-06 Cont ID  
Sent By jgomez Date 2000-12-06 Time 15:01 Rev Time 0.00
Received By jgomez Date 2000-12-06 Time 15:01 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2000-12-04 Cont ID  
Sent By jgomez Date 2000-12-04 Time 17:13 Rev Time 1.50
Received By jgomez Date 2000-12-04 Time 17:13 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE SIGNED AND SEALED ENGINEERED
 TRUSSES.
 2-PRODUCT APPROVAL FOR DOORS AND WINDOWS
 ARE MISSING THE DRAWINGS. PLEASE
 SUBMIT THEM.
 3-APPLY FOR SEPARATE PERMITS FOR
 ELECTRICAL, PLUMBING AND ROOFING.
 SUBS DIDN'T SIGN THE ORIGINAL
 APPLICATION.
 4-PROVIDE PRODUCT APPROVAL FOR FLAT ROOF
 SYSTEM AND ROOF SHINGLES.
  
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-10-12 Cont ID  
Sent By jgomez Date 2000-10-12 Time 17:42 Rev Time 1.50
Received By jgomez Date 2000-10-12 Time 17:42 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-CONNECTORS SPECIFIED ON NEW DRAWINGS
 BY TURQUOISE, INC ARE NOT CORRECT.
 CHECK SEMCO CATALOGUE AND SPECIFY
 PROPER CONNECTORS. SEE PLANS FOR
 COMMENTS.
 2-SECTION A-A SHOWS CONNECTORS FOR
 RAFTERS AT FLAT ROOF ONLY.
 SPECIFY CONNECTORS FOR NEW TRUSSES.
 3-SPECIFY HOW IS CROSS VENTILATION FOR
 NEW ATTIC ACHIEVED.
 SEE SECTION 2309.7 SBC 1997.
 4-CONNECTORS SPECIFIED FOR ROOF TRUSSES
 DON'T HAVE ANY ENGINEERED VALUE FOR
 LATERAL FORCES. SEE ANCHOR CATALOGUE
 AND ENGINEERED TRUSS.
 SPECIFY ANCHOR WITH VALUES FOR UPLIFT
 AND LATERAL FORCES AS REQUIRED.
 5-SPECIFY ANCHORING OF GABLE END TRUSS.
 SEE ENGINEERED TRUSS.
 6-ROOF TRUSSES:
 -THERE ARE 2 DIFFERENT TRUSS COMPANIES.
 DECIDE WHICH ONE IS GOING TO BE USED.
 -TRUSS DRAWINGS TO BE UPDATED & CLEARLY
 SPECIFY IF USING ASCE 7-95 FOR 145 MPH
 WIND LOAD OR SBC 1997 FOR 110 MPH WIND
 LOAD.
 -TRUSS LAYOUT AND ENGINEERED TRUSSES TO
 BE SIGNED, SEALED AND DATED AND WITH
 INFORMATION REQUIRED BY CHAPTER 471 OF
 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 -PROFESSIONAL OF RECORD TO REVIEW ALL
 TRUSS DRAWINGS PRIOR TO SUBMITTAL TO
 THIS OFFICE.
 7-PROVIDE PRODUCT APPROVALS FOR:
 -OUTSWING FRENCH DOORS.
 -OUTSWING DOOR AT KITCHEN.
 -INSWING DOOR AT BATH.
 -SINGLE HUNG WINDOW.
 -FLAT ROOF SYSTEM.
 -SHINGLES.
 8-STORM PANELS:
 -PROVIDE PRODUCT APPROVAL.
 -PROVIDE A COMPLETE INSTALLATION
 SCHEDULE AS PER CITY SAMPLE ATTACHED
 AND A KEY PLAN.
 -CLEARLY INDICATE ON STORM PANELS DWGS
 THE MOUNTING METHOD AND ANCHOR AND
 SPACING TO BE USED ACCORDINT TO THE
 STRUCTURE TO BE ATTACHED TO.
 9-SEE ADDITIONAL COMMENTS ON PLANS,
 INCLUDING COMMENTS BY THE OTHER TRADES
 10-CONTRACTOR NEEDS TO UPDATE LICENSE.
  
  
  
  
 NOTES:
  
 1-SEPARATE PERMITS AND FEES WILL BE
 REQUIRED FOR MECHANICAL, ELECTRICAL,
 PLUMBING AND ROOFING.
 2-RETURN REVIEWED SET AFTER CORRECTIONS
 ARE DONE TO ORIGINAL DRAWING IN ORDER
 TO EXPEDITE THE REVIEW PROCESS.
 3-IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-30 Cont ID  
Sent By jgomez Date 2000-06-30 Time 19:48 Rev Time 0.00
Received By sjohnson Date 2000-07-10 Time 11:36 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 2-CLEARLY WRITE NAME, LICENSE NUMBER,
 ADDRESS AND PHONE NUMBER OF ENGINEER.
 FLORIDA STATUTES CHAPETER 471.
 3-SPECIFY CEILING CONSTYRUCTION AT REAR
 PORCH. INCLUDE FASTENER TYPE AND
 SPACING. SEC 104.2.2 CITY AMENDMENTS.
 4-UPDATE TRUSS DRAWING LAYOUT. THE CITY
 HAS ADOPTED SBC 1997.
 -TRUSS ENGINEER TO SIGN, SEAL AND DATE
 TRUSS LAYOUT. ALSO, PROVIDE TWO COPIES
 OF ENGINEERED ROOF TRUSSES, SIGNED,
 SEALED AND DATED RESPECTIVELY.
 -ENGINEER OF RECORD FOR ADDITION TO
 REVIEW ALL TRUSS DRAWINGS PRIOR TO
 SUBMITTAL.
 5-STRUCTURAL NOTES:
 -PROVIDE UPLIFT CALCULATIONS.
 -CLEARLY INDICATE CONNECTORS AT THE END
 OF PORCH BEAMS.
 -PROVIDE CLEAR SECTION DETAIL AT INTER-
 SECTION OF FLAT ROOF AND ENGINEERED
 ROOF TRUSSES. INDICATE ATTACHMENT OF
 WOOD LEDGER TO 2X4 BEARING WALL.
 SPECIFY ALL FASTENERS.
 -SPECIFY CONDITIONS AT OPENING OF
 BEARING WALL AT KITCHEN AREA. SHORING,
 EXISTING BEAM OR LINTEL, ETC.
 -SPECIFY ANCHORING FOR GABLE END ROOF
 TRUSS.
 -PROVIDE COMPLETE DETAIL AT NEW STEEL
 COLUMN SHOWING TOP & BOTTOM CONNECTION
 -PROVIDE COMPLETE BUCK DETAIL FOR NEW
 EXTERIOR DOORS AND WINDOWS.
 -PROVIDE DESIGN PRESSURES CALCULATIONS
 FOR ALL EXTERIOR OPEN'GS. SEC 1606 SBC
 -SEE PLANS FOR ADDITIONAL COMMENTS.
 -PROVIDE SPECIFICATIONS/DETAILS FOR
 ATTACHMENT OF EXISTING WALL AND FOOT'G
 TO NEW WALLS AND FOOTING.
 6-UPDATE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. CITY
 ADOPTED THE 1997 SBC. OR ASCE 7-97.
 -THE MEAN ROOF HEIGHT & BASIC VELOCITY
 PRESSURE DO NOT MATCH.SEE TABLE
 1606.2A SBC 1997.
 -CORRECTLY FILL IN ALL INFORMATION ON
 TOP OF FORM.
 7-PROVIDE CURRENT PRODUCT APPROVALS FOR:
 FRENCH DOORS, SWING DOORS, WINDOWS,
 FLAT ROOF SYSTEM AND SHINGLES.
 8-STORM PANELS:
 -PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS. SEE ATTACHED COPY OF POLICY.
 -PROVIDE A CURRENT PRODUCT APPROVAL.
 -PROVIDE A COMPLETE INSTALLATION SCHED.
 (SEE BACK OF POLICY, ATTACHED) AND KEY
 PLAN.
 -CLEARLY INDICATE MOUNTING METHOD AND
 ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE MEAN ROOF HEIGHT,
 DESIGN PRESSURES, STORM PANEL SPAN,
 EDGE DISTANCE AND STRUCTURE TO BE
 ATTACHED TO.
 9-OWES $TO THE CITY FOR LOW BLDG
 VALUATION ABD RADON FEES. PLEASE PAY
 ATTACHED RECEIPT.
  
 NOTE:
 PLEASE RETURN REVIEWED SETS AFTER THE
 CORRECTIONS ARE DONE IN ORDER TO
 EXPEDITE THE REVIEW PROCESS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-06-02 Cont ID  
Sent By gjoyce Date 2000-06-02 Time 11:46 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***