| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | 2-PROVIDE EGRESS AT BEDROOM. SEE SECTION |
| | 1005.4 SBC 1997. |
| | 3-PROVIDE COMPLETE BEAM AND LINTEL |
| | SCHEDULE WITH COMPLETE SPECS. ALSO, |
| | SPECIFY CONSTRUCTION OF WINDOW SILLS |
| | TO RECEIVE STORM PANELS. |
| | SECTION 104.2.2 CITY AMENDMENTS. |
| | 4-NOTICE OF COMMENCEMENT NEEDS TO BE |
| | RECORDED WITH PALM BEACH COUNTY. |
| | 5-PROVIDE SAFETY GLASS WHERE REQUIRED. |
| | SEE PLANS FOR COMMENTS. SECTION 2405.2 |
| | SBC 1997. |
| | 6-SEE PROVISO AND COMMENTS BY OTHER PLAN |
| | REVIEWERS. |
| | 7-PROVIDE UPLIFT CALCULATIONS FOR ROOF |
| | TRUSSES. SEC 104.2.2 CITY AMENDMENTS. |
| | 8-SPECIFY FIREBLOCKING WHERE REQUIRED. |
| | SECTION 2305 SBC 1997. |
| | 9-ENGINEER TO CERTIFY THAT EXISTING ROOF |
| | TRUSSES AND CONNECTORS ARE ADEQUATE TO |
| | RECEIVE THE NEW ROOF LOADS AND |
| | REACTIONS. SEC 104.2.2 CITY AMENDMENTS |
| | 10-PROVIDE CURRENT SIGNED, SEALED AND |
| | DATED SURVEY SHOWING THE ADDITION. |
| | 11-STORM PANELS: |
| | -PROVIDE A COMPLETE INSTALLATION,AS PER |
| | CITY SAMPLE ATTACHED, AND KEY PLAN. |
| | -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS |
| | AND ANCHOR SPACING ACCORDING TO THE |
| | DESIGN PRESSURES, PANEL SPAN, EDGE |
| | DISTANCE AND STRUCTURE TO BE ATTACHED |
| | 12-CLARIFY IF THIS ADDITION IS GOING TO |
| | BE AIR CONDITIONED. IF SO, PROVIDE |
| | THE REQUIRED ENERGY CALCULATIONS. |
| | -IF NOT AIR CONDITIONING IS INSTALLED, |
| | THEN PROVIDE ADEQUATE VENTILATION AS |
| | PER SECTION 1203.4.2 SBC 1997. |
| | -PROVIDE LIGHT AND VENTILATION FOR |
| | BEDROOM AS PER SECTION 1203.1.2 SBC/97 |
| | -PROVIDE A/C DRAWINGS FOR REVIEW. |
| | 13-PROVIDE PRODUCT APPROVALS FOR: |
| | AWNING WINDOWS, EXTERIOR SWING DOOR, |
| | SLIDING GLASS DOORS, ROOF SHINGLES FOR |
| | A WIND VELOCITY OF 110 MPH. |
| | 14-CLARIFY WHAT TYPE OF WINDOWS ARE |
| | GOING TO BE USED IN THIS HOUSE. AWNING |
| | WINDOWS OR SINGLE HUNG WINDOWS. |
| | 15-PROVIDE COMPLETE ENGINEERED TRUSS |
| | DRAWINGS REVIEWED BY THE ENGINEER OF |
| | RECORD OF THIS ADDITION. |
| | 16-REVISE THE DESIGN CERTIFICATION FOR |
| | BUILDING CODE COMPLIANCE FORM: |
| | -MEAN ROOF HEIGHT IS INCORRECT. |
| | MEAN ROOF HEIGHT IS TAKEN FROM FINISH |
| | GRADE TO THE AVERAGE POINT OF THE |
| | HIGHEST ROOF. |
| | -COMPLETE BASIC VELOCITY PRESSURE. SEE |
| | TABLE 1606.2A SBC 1997. |
| | 17-PROVIDE THE DESIGN PRESSURES AT ALL |
| | EXTERIOR OPENINGS. SEC 1606 SBC 1997. |
| | 18-OWES $51.29FOR RADON FEES AND |
| | BUILDING VALUATION. THIS IS TO BE PAID |
| | TO THE CITY OF WEST PALM BEACH. SEE |
| | ATTACHED PAYMENT RECEIPT. |
| | |
| | |
| | |
| | NOTE: |
| | PLEASE RETURN REVIEWED SETS IN ORDER TO |
| | EXPEDITE THE REVIEW PROCESS. |